  4. Analysis of the surface plasmon resonance interferometric imaging performance of scanning confocal surface plasmon microscopy
Loading...
Thumbnail Image

Analysis of the surface plasmon resonance interferometric imaging performance of scanning confocal surface plasmon microscopy

Author(s)
Tontarawongsa, Sorawit
Visitsattapongse, Sarinporn
Pechprasarn, Suejit
Date Issued
January 1, 2021
Type
Article
DOI
10.1364/BOE.448085
Abstract
Here, we apply rigorous coupled-wave theory to analyze the optical phase imaging performance of scanning confocal surface plasmon microscope. The scanning confocal surface plasmon resonance microscope is an embedded interferometric microscope interfering between two integrated optical beams. One beam is provided by the central part around the normal incident angle of the back focal plane, and the other beam is the incident angles beyond the critical angle, exciting the surface plasmon. Furthermore, the two beams can form an interference signal inside a confocal pinhole in the image plane, which provides a well-defined path for the surface plasmon propagation. The scanning confocal surface plasmon resonance microscope operates by scanning the sample along the optical axis z, so-called V(z). The study investigates two imaging modes: non-quantitative imaging and quantitative imaging modes. We also propose a theoretical framework to analyze the scanning confocal surface plasmon resonance microscope compared to non-interferometric surface plasmon microscopes and quantify quantitative performance parameters including spatial resolution and optical contrast for non-quantitative imaging; sensitivity and crosstalk for quantitative imaging. The scanning confocal SPR microscope can provide a higher spatial resolution, better sensitivity, and lower crosstalk measurement. The confocal SPR microscope configuration is a strong candidate for high throughput measurements since it requires a smaller sensing channel than the other SPR microscopes.
Citation
Biomedical Optics Express, 13(1), 485-501, 2021
Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback