  4. Analysis and Comparison of Characteristics for Offline PD Measurements in Turbo-Generators at Different Test Time Intervals
Loading...
Thumbnail Image

Analysis and Comparison of Characteristics for Offline PD Measurements in Turbo-Generators at Different Test Time Intervals

Author(s)
Dorkmai, K.
Pannil, P.
Tattiwong, K.
Maneerot, S.
Suksawat, D.
Pattanadech, N.
Date Issued
January 1, 2022
Type
Conference Paper
DOI
10.23919/CMD54214.2022.9991528
Abstract
Partial discharge (PD) measurement is widely used for the condition assessment of high voltage equipments. It is a tool to detect the localized discharges occurring in the weakness point sites, which causes deterioration that can lead to failure. Hence, it is essential to diagnose the PD behavior to prevent the consequent failure which maybe takes place. This paper presents an analysis of the offline PD measurements performed on the stator winding insulation system of three turbo-generators which consist of a hydrogen-cooled generator rate of 211.75 MVA, 15.75 kV, and two air-to-water heat-cooled generators which the same rate of 50.8 MVA, 11.5 kV, which were located in the power plant. Firstly, the offline PD measurements of these generators have been energized to the star point side and the high voltage coupling capacitor is installed on the high voltage terminal side, according to IEC 60034-27-1. Additionally, the test voltages were applied to the test object with a step voltage profile. To analyze the PD behaviors of the stator winding insulation, the PD characteristics such as the PD pulses, PD magnitude, and phase-resolved PD (PRPD) patterns were monitored and recorded. Besides, the effect of applied test voltage-time, i.e., 1, 3, and 5 minutes, on such characteristics were reported and compared. Finally, the PD behavior of the stator winding insulation of these generators showed clearly different results for PD measured at different recording times. The highly fluctuating PD magnitude and PD pulse shape at the initial duration of the measurement, and then gradually decreases to convergence to a stable charge magnitude as the test-time increases.
Citation
2022 9th International Conference on Condition Monitoring and Diagnosis Cmd 2022, 103-107, 2022
Subjects

Different test time

Partial discharge

PD in rotating machin...

PD test time interval...

Turbo-generators

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback