Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Smartphone-based disposable cotton-swab sensor loaded with creatinine/Cu–chlorophyllin–stabilized AuNPs for ultrasensitive RGB colorimetric detection of mercury (II) ions in aquatic environments
Loading...
Thumbnail Image

Smartphone-based disposable cotton-swab sensor loaded with creatinine/Cu–chlorophyllin–stabilized AuNPs for ultrasensitive RGB colorimetric detection of mercury (II) ions in aquatic environments

Author(s)
Lerdpiriyaskulkij, Natee
Detsri, Ekarat
Teerasong, Saowapak
Chansai, Sarayute
Mathaweesansurn, Arjnarong
Date Issued
May 1, 2026
Type
Article
DOI
10.1016/j.snb.2026.139592
Abstract
A simple, rapid, selective, and sensitive colorimetric sensor based on a disposable cotton swab loaded with Au nanoparticle–modified Cu-chlorophyllin (Au0–NPsCHL) and creatinine was developed for mercury (II) detection in aquatic environments using smartphone–based RGB analysis. Au0–NPsCHL were synthesized by ultrasonic-assisted chemical reduction, employing Cu-chlorophyllin as a stabilizing and NaBH4 as a reducing agent. A vivid red Au0–NPsCHL colloidal (7.96 ± 0.29 nm) with a sharp SPR peak at 515 nm was successfully obtained. An aliquot of 75 µL of Au0-NPsCHL (0.103 ± 0.03 nmol L−1) and 25 µL of creatinine solution (40 mg L−1) were sequentially loaded into an 8.0 × 0.5 cm cotton swab, separated by a 0.5 cm air gap. Detection began by immersing the swab into Hg2+–contaminated samples for 3 min, allowing Hg2+ adsorption. Breaking the swab generated pressure differential, which, along with gravity, drove the Au0–NPsCHL to mix with creatinine. The resulting mixture migrated toward the swab tip by capillary action and reacted with adsorbed Hg2+ through metallophilic 5d10–5d10 interactions. Creatinine acted as a bridging ligand, inducing Au0–NPsCHL aggregation and shifting the SPR to 620 nm, causing a visible red-to-blue transition. This sensor enables rapid and visual detection and quantitative evaluation via smartphone RGB analysis. The system demonstrated excellent linearity from 1 to 100 µg L−1 with a low LOD of 0.82 µg L−1. Recoveries of 97.6–101.8 % confirmed high accuracy and minimal matrix interference. The disposable cotton swab RGB sensor provides a rapid, portable, and practical tool for on-site primary assessment of Hg2+ contamination in environmental samples.
Citation
Sensors and Actuators B Chemical, 454, 2026
Subjects

Cu-chlorophyllin

Disposable cotton sti...

Gold nanoparticles

Induce-aggregation

Mercury (II)

Smartphone-based RGB

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback