Abstract
The article presents an experimental investigation on turbulent heat transfer and friction loss behaviors of airflow through a constant heat-fluxed channel fitted with different heights of triangular ribs. The rib cross-section geometry used in the present study was isosceles triangle. Two rib arrangements, namely, in-line and staggered arrays, were introduced. Measurements were carried out for a rectangular channel of aspect ratio, AR = 10 and height, H = 30 mm with three uniform rib heights, e = 4, 6 and 8 mm (e/H = 0.13, 0.2 and 0.26) and one non-uniform rib height, e = 4,6 mm (e/H = 0.13,0.2) alternately for a single rib pitch, P = 40 mm. The flow rate in terms of Reynolds numbers based on the inlet hydraulic diameter of the channel was in a range of 5000 to 22,000. The experimental results show a significant effect of the presence of the ribs on the heat transfer rate and friction loss over the smooth wall channel. The uniform rib height performs better than the corresponding non-uniform one. The in-line rib arrangement provides higher heat transfer and friction loss than the staggered one for a similar mass flow rate. In comparison, the largest e/H rib with inline array yields the highest increase in both the Nusselt number and the friction factor values but the lowest e/H rib with staggered array provides the best thermal performance. © 2009 Elsevier Ltd. All rights reserved.
Citation
International Communications in Heat and Mass Transfer, 36(7), 712-717, 2009
Subjects

Channel flow

Enhanced heat transfe...

Rectangular duct

Triangular rib

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback