Development of a low-pass filter for partial discharge testing system with the power frequency converter

Author(s)
Prombud, T.
Kitcharoen, P.
Yutthagowith, P.
Date Issued
November 1, 2018
Type
Conference Paper
DOI
10.1109/AUPEC.2018.8757986
Abstract
The development of a low-pass filter for partial discharge test system that based on a power frequency converter is presented in this paper. The PD testing system is composed a 200-Hz power frequency converter and the designed filter connected with a high-voltage test transformer and a conventional partial discharge detection system. It is found that the power frequency converter acting as the low-voltage source always provides the high noise level with effecting to the background noise occur in the partial discharge test. Sometimes noise level is higher than the acceptable level of the PD tests in some high-voltage equipment such as potential transformers, distribution transformer, and so on. In this paper, the performances of the filters with different designs are studied and compared the result in terms of the output voltage difference (RMS, voltage , and ,peak,voltage 2), total harmonic distortion of the output high voltages value (THDv), and value of background noises as occur in the partial discharge test. The low-voltage source based on uni-polar pulse width modulation (PWM) topology was employed in the PD testing system. From the experimental results, the designed filter shows the promising performances with low levels of the background noise, THDv, and voltage difference. The experimental results show that the background noise is lower than 2.0 pC, the voltage difference and THDv are less than 5%. In addition, the designed filter has been tested in the partial test of a real potential transformer successfully.
Citation
Australasian Universities Power Engineering Conference Aupec 2018, 2018
Subjects

frequency converter

high-voltage tests

low-pass filter

partial discharge

potential transformer...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback