Analysis of reset time for a novel three-phase three-level ZVZCS DC-DC converter using phase-shift PWM strategy
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The paper presents an analysis about the reset time of the primary current for a novel three-phase three-level ZVZCS DC-DC converter using phase-shift PWM strategy. The analysis shows the presence of the ZVS turn-on condition at outer switches of Branches A, B and C, ZVZCS turn-on and turn-off conditions at inner switches of the branches. For ZCS turn-off conditions at inner switches, DC blocking capacitors also affects resetting of the primary current directly and validates the consistency between simulation results using MATLABR and experimental results, which exhibits good agreement. The converter has maximum efficiency of 93.50% at 5.6 kW.