Analysis of reset time for a novel three-phase three-level ZVZCS DC-DC converter using phase-shift PWM strategy

dc.contributor.authorKongwirat, Thammachat
dc.contributor.authorJangwanitlert, Anuwat
dc.date.accessioned2026-08-06T10:11:12Z
dc.date.available2026-08-06T10:11:12Z
dc.date.issued2015-01-26
dc.description.abstractThe paper presents an analysis about the reset time of the primary current for a novel three-phase three-level ZVZCS DC-DC converter using phase-shift PWM strategy. The analysis shows the presence of the ZVS turn-on condition at outer switches of Branches A, B and C, ZVZCS turn-on and turn-off conditions at inner switches of the branches. For ZCS turn-off conditions at inner switches, DC blocking capacitors also affects resetting of the primary current directly and validates the consistency between simulation results using MATLABR and experimental results, which exhibits good agreement. The converter has maximum efficiency of 93.50% at 5.6 kW.
dc.identifier.citationIEEE Region 10 Annual International Conference Proceedings TENCON, 2015-January, 2015
dc.identifier.doi10.1109/TENCON.2014.7022386
dc.identifier.issn21593442
dc.identifier.other2-s2.0-84940535181
dc.identifier.urihttps://dspace.kmitl.ac.th/handle/123456789/6146
dc.sourceIEEE Region 10 Annual International Conference Proceedings TENCON
dc.subjectblocking capacitors
dc.subjectDC-DC converter
dc.subjectreset time
dc.subjectthree-phase three-level converter
dc.subjectZVZCS
dc.titleAnalysis of reset time for a novel three-phase three-level ZVZCS DC-DC converter using phase-shift PWM strategy
dc.typeConference Paper

Files