KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
2 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Use of computational fluid dynamics nasal airflow measurement to design septoplasty: A pilot study(2013-01-01) ;Mahasittiwat, Visan ;Hemtiwakorn, KhaisangPintavirooj, ChuchartDeviation in the nasal septum that obstructs airflow is a source of discomfort to patients. Areas of nasal malformation then, need to be identified before performing surgery. In the present study, the authors introduce the computational fluid dynamic (CFD) technique to predict regions of limited airflow based on CT scan reconstruction of the nasal cavity. The present study proposes to use CFD to identify regions of obstructed airflow and design a surgical procedure to correct them. The authors report three cases with obstructed nasal airflow together with CFD measurements before and after the surgery. Results indicate that CFD is useful to verify the areas of airflow abnormality and conform with the results obtained using other methods. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Combined medical imaging with CFD analysis for application of diagnostic and treatment planning: The case study of human nasal airflow simulation based on CT imaging(2009-01-01) ;Hemtiwakorn, Khaisang ;Phoocharoen, Niwat ;Tungjitkusolmun, Supan ;Mahasittiwat, VisanSangworasil, ManasThe previous methods of human airflow measurement such as rhinomanometry or acoustic rhinometry could not visualize the airflow and calculated the velocity magnitude in specific region of nasal cavity. Thus, this study proposes the combination of CT and CFD analysis of nasal airflow simulation in normal human breathing. This method can demonstrate the airflow direction, and also calculate the velocity magnitude inside the nasal cavity. The processes of this study are segmentation, meshing, solving, and post-processing. Firstly, Mimic 10.01 software was used to segment the nasal cavity. Secondly, Pro-STAR/amm software was used to generate trimmed mesh of 338, 496 elements. Finally, computational grid model was imported to STAR-CD version 3.26 for numerical computation, and visualize the solution by post-processing. The result shows that velocity magnitude of airflow is greatest in nasal valve area which is the narrowest area of the human nose. Also, the flow commonly pass through the main nasal passage and middle meatus areas of nose. Experimental validation will be reported in the further publication. In conclusion, this study is the important begining of an applied CFD analysis with medical imaging. CT imaging combines with CFD analysis could be useful for rhinologist as a nose function evaluation technique. Moreover, the applications of this method could be utilized in a wide range of research topics, especially development of diagnostic and treatment planning techniques.