KMITL

Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/kmitl/1

Browse

Search Results

Now showing 1 - 2 of 2
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Impact of Rising Number of Electric Vehicle Charging Points on Electrical Utility
    (2025-01-01)
    Chiradeja, Pathomthat
    ;
    Lertwanitrot, Praikanok
    ;
    Songsukthawan, Panapong
    ;
    ;
    This paper presents an investigation of the impact of a rising number of electric-vehicle charging points on an interconnected distribution system. Using the PSCAD 4.6 software, this study simulates an electric-vehicle charging station consisting of a charging unit with 2 DC charging and a maximum power of 100 kW. The station receives power from a 23 kV substation through a step-down transformer at 400 V and provides power through the charging unit. The unit regulates the voltage level at 500 V and has a maximum charging capacity of 50 kW each. In addition, the study replicates an actual distribution system of the Provincial Electricity Authority (PEA) in the section spanning the Si Samrong to Sawankhalok substations in Sukhothai Province, Thailand. The effects of the following study conditions on the power quality are observed in the simulation: 1) variable location of charging panels, 2) variable number of charging panels, and 3) additional sets of charging panels in the distribution system. The results show that the charging-panel installation location and number of charging panels are significant factors that affect the power quality, including the voltage level. Therefore, optimizing the design of EV charging stations should consider the location and number of charging panels as important factors.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Impact of Wind Power Generation Sizing on the Characteristic of Distribution System Under Fault Condition
    (2022-01-01) ;
    Leelajindakrairerk, Monthon
    ;
    ; ;
    Songsukthawan, Panapong
    In the recent decade, there has been a rising concern in energy consumption and environmental issues. This trend has shifted the electric authority to focus from fossil fuel to renewable energy. The distributed generation (DG) using a renewable energy source has been raising. The presence of DG can cause using renewable energy sources to cause a technical issue on system protection and operation. This paper aims to study the impact of different DG size installations on the distribution system in terms of the system characteristics. The study is done in both normal conditions and in cases of fault occurrence. The system using in this research is a 22-kV distribution system consists of Wind Power Generation as the DG connected into the distribution line that modeled after part of the Provincial Electricity Authority (PEA) in the northern part of Thailand. The simulation was done using PSCAD software. The result from simulation reveals the impact of DG on the distribution system characteristics in terms of significant change in the measured current and voltage signal. Thus, the analysis of the impact of DG on the system must be done to ensure the reliability of the power system.
      1