KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
2 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Ultrasensitive Label-Free Electrochemical Detection of Pseudomonas aeruginosa Using a Surface Molecularly Imprinted Polymer-Modified Screen-Printed Electrode(2026-06-01) ;Vongmanee, Naphatsawan ;Nampeng, Jindapa ;Pintavirooj, ChuchartVisitsattapongse, SarinpornPseudomonas aeruginosa is a major opportunistic pathogen frequently associated with nosocomial infections, such as pneumonia, urinary tract infections, and wound infections, particularly in immunocompromised or hospitalized patients. These infections are often difficult to treat due to the pathogen’s intrinsic antibiotic resistance and biofilm-forming ability. Therefore, rapid and selective detection of P. aeruginosa is essential for early diagnosis and effective infection control. In this study, a novel surface-imprinted MIP design uniquely combines methacrylamide (MAM), acrylamide (AAM), and vinylpyrrolidone (VP) monomers to generate recognition cavities that are complementary to the surface morphology and physicochemical properties of Pseudomonas aeruginosa cells. Unlike traditional MIP approaches, this surface imprinting strategy provides improved stability and reproducibility, without relying on biological recognition elements like antibodies or aptamers. This novel approach enabled us to achieve an ultralow LOD of 1 CFU/mL over a linear range of 1–10<sup>4</sup> CFU/mL, demonstrating excellent analytical performance. In addition, the sensor exhibited good reproducibility with an RSD of 5–12%. The novelty of this work lies in the use of a surface-imprinted MIP strategy combined with a multi-monomer system to enhance bacterial recognition and sensing performance. Overall, the proposed MIP-based electrochemical biomimetic sensor offers a rapid, cost-effective, and portable platform with strong potential for the detection of P. aeruginosa in clinical and environmental applications. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Electrochemical Biosensors by Means of Molecularly Imprinted Polymers (MIPs) Cortisol Recognition(2025-02-01) ;Nampeng, Jindapa ;Vongmanee, Naphatsawan ;Pintavirooj, Chuchart ;Chiu, Wen TaiVisitsattapongse, SarinpornDepression and anxiety are two common mental health issues that require serious attention, as they have significant impacts on human well-being, with both being emotionally and physically reflected in the increasing number of suicide cases globally. The World Health Organization (WHO) estimated that about 322 million people around the world experienced mental illnesses in 2017, and this number continues to increase. Cortisol is a major stress-controlled hormone that is regulated by the hypothalamic–pituitary–adrenal (HPA) axis. The HPA axis has three main components, including the hypothalamus, pituitary gland, and adrenal gland, where cortisol, the primary stress hormone, is released. It plays crucial roles in responding to stress, energy balance, and the immune system. The cortisol level in the bloodstream usually increases when stress develops. Molecularly imprinted polymers (MIPs) have been highlighted in terms of creating artificial bioreceptors by mimicking the shape of detected biomolecules, making natural bioreceptor molecules no longer required. MIPs can overcome the limitations of chemicals and physical properties reducing over time and the short-time shelf life of natural bioreceptors. MIPs’ benefits are reflected in their ease of use, high sensitivity, high specificity, reusability, durability, and the lack of requirement for complicated sample preparation before use. Moreover, MIPs incur low costs in manufacturing, giving them a favorable budget for the market with simple utilization. MIPs can be formulated by only three key steps, including formation, the polymerization of functional monomers, and the creation of three-dimensional cavities mimicking the shape and size of targeting molecules. MIPs have a high potential as biosensors, especially working as bioanalytics for protein, anti-body, antigen, or bacteria detection. Herein, this research proposes an MIP-based cortisol biosensor in which cortisol is imprinted on methyl methacrylate (MMA) and methacrylic acid (MAA) produced by UV polymerization. This MIP-based biosensor may be an alternative method with which to detect and monitor the levels of hormones in biological samples such as serum, saliva, or urine due to its rapid detection ability, which would be of benefit for diagnosing depression and anxiety and prescribing treatment. In this study, quantitative detection was performed using an electrochemical technique to measure the changes in electrical signals in different concentrations of a cortisol solution ranging from 0.1 to 1000 pg/mL. The MIP-based biosensor, as derived by calculation, achieved its best detection limit of 1.035 pg/mL with a gold electrode. Tests were also performed on molecules with a similar molecular structure, including Medroxyprogesterone acetate and drospirenone, to ensure the sensitivity and accuracy of the sensors, demonstrating a low sensitivity and low linear response.
