    Cuff-Less Blood Pressure Prediction from ECG and PPG Signals Using Fourier Transformation and Amplitude Randomization Preprocessing for Context Aggregation Network Training
    (2022-03-01) ;
    Boosamalee, Apivitch
    ;
    Shinnakerdchoke, Siratchakrit
    ;
    Pechprasarn, Suejit
    ;
    Thongpance, Nuntachai
    This research proposes an algorithm to preprocess photoplethysmography (PPG) and electrocardiogram (ECG) signals and apply the processed signals to the context aggregation network-based deep learning to achieve higher accuracy of continuous systolic and diastolic blood pressure monitoring than other reported algorithms. The preprocessing method consists of the following steps: (1) acquiring the PPG and ECG signals for a two second window at a sampling rate of 125 Hz; (2) separating the signals into an array of 250 data points corresponding to a 2 s data window; (3) randomizing the amplitude of the PPG and ECG signals by multiplying the 2 s frames by a random amplitude constant to ensure that the neural network can only learn from the frequency information accommodating the signal fluctuation due to instrument attachment and installation; (4) Fourier transforming the windowed PPG and ECG signals obtaining both amplitude and phase data; (5) normalizing both the amplitude and the phase of PPG and ECG signals using z-score normalization; and (6) training the neural network using four input channels (the amplitude and the phase of PPG and the amplitude and the phase of ECG), and arterial blood pressure signal in time-domain as the label for supervised learning. As a result, the network can achieve a high continuous blood pressure monitoring accuracy, with the systolic blood pressure root mean square error of 7 mmHg and the diastolic root mean square error of 6 mmHg. These values are within the error range reported in the literature. Note that other methods rely only on mathematical models for the systolic and diastolic values, whereas the proposed method can predict the continuous signal without degrading the measurement performance and relying on a mathematical model.
      1
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Study of ECG variation in daily activity
    (2017-12-19)
    Samona, Yanisa
    ;
    ;
    Electrocardiogram (ECG) records electrical activity of the heart spreading through the heart muscle to make the heart contract. Recently ECG has been captured attention as biometric feature due to its uniqueness and large reliabilities for human identifications. In this study we aimed to verify the conservative ECG of human in their activities to ensure whether it is suitable to be used as biometric devices. Experiment studies involved 6 participants of which the age ranges is between 21 and 23. We test the robustness of ECG under various situation including health condition, emotional state and heart rate variation. The recorded ECG signal is forwarded for analysis using Matlab. Correlation coefficient of ECG Fourier transform is used as criterion to validate the ECG robustness. The result indicates that ECG is not stable and seems to vary with daily activity and emotional state. This will hampers ECG to be used as Biometric.
      1
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Heart detection and diagnosis based on ECG and EPCG relationships
    (2011-08-26)
    Phanphaisarn, W.
    ;
    Roeksabutr, A.
    ;
    ; ;
    Yupapin, PP
    A new design of a system for preliminary detection of defective hearts is proposed which is composed of two subsystems, in which one is based on the relationship between the electrocardiogram (ECG) and phonocardiogram (PCG) signals. The relationship between both signals is determined as an impulse response (h(n)) of a system, where the decision is made based on the linear predictive coding coefficients of a heart's impulse response. The other subsystem uses a phase space approach, in which the mean squared error between the distance vectors of the phase space of the normal heart and abnormal heart is judged by the likelihood ratio test (Λ) value, on which the decision is made. The advantage of the proposed system is that a heart's diagnosis system based on the ECG and EPCG signals can lead to high performance heart diagnostics. © 2011 Phanphaisarn et al, publisher and licensee Dove Medical Press Ltd.