KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/kmitl/1
Browse
2 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Distributed Temperature Sensing and Real Time Thermal Rating for Underground Power Cable Monitoring(2025-01-01) ;Tangtheerajaroonwong, Wiroj ;Tanapornchinpong, Phiphat ;Kiatjaroonlert, Boonsak ;Khan-Ngern, WerachetSangracha, ChanintornThis paper presents the distributed temperature sensing (DTS) technology and its application mainly on underground power cables. The main measuring principle is detecting the back-scattering light via Raman scattering that varies and depends on temperature at each point of optical fiber. In this paper, the authors present the monitoring results that the load current is applied for 50% of the rated current of the 69 kV and 115 kV transmission cables, and the DTS detects temperature increasing 0.5°C from the ambient temperature. This paper also shows real time thermal rating for calculations of conductor temperature.1 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Accurate Loss Tangent Determination in Damped Alternating Voltage Tests(2024-01-01); ; Paophan, BusayapolUnderground cables are crucial for sustainable energy systems due to their minimal visual impact, reliability, and resilience against weather-related disruptions. As reliance on renewable energy sources rises, their importance grows. Regular evaluation of these cables is essential for ensuring safety, reliability, and resilience of electricity networks. By promptly identifying risks like insulation degradation, utilities can optimize maintenance, prioritize repairs, and bolster the integration of renewables, enhancing overall infrastructure performance. Loss tangent is the most significant value used for evaluation of the cable condition. This paper presents an alternative method for estimation of loss tangent in comparison with a conventional approach in damped alternating current voltage (DACV) tests. In the loss tangent estimation, the equivalent circuit of the DACV test system and a damping factor of the measured test voltage are utilized in the loss tangent estimation. From simulation experimental results, it is found that the conventional method is not accurate in loss tangent estimation in cases of low loss tangent measurement in the range of 0.1% which is a typical value of the new and used underground power cables. However, the accuracy of the proposed method is still in the acceptable range for estimation of the loss tangent in the range of 0.1%1