Item type:Publication, Analysis and Comparison of Characteristics for Offline PD Measurements in Turbo-Generators at Different Test Time Intervals(2022-01-01) ;Dorkmai, K.; ;Tattiwong, K. ;Maneerot, S.Partial discharge (PD) measurement is widely used for the condition assessment of high voltage equipments. It is a tool to detect the localized discharges occurring in the weakness point sites, which causes deterioration that can lead to failure. Hence, it is essential to diagnose the PD behavior to prevent the consequent failure which maybe takes place. This paper presents an analysis of the offline PD measurements performed on the stator winding insulation system of three turbo-generators which consist of a hydrogen-cooled generator rate of 211.75 MVA, 15.75 kV, and two air-to-water heat-cooled generators which the same rate of 50.8 MVA, 11.5 kV, which were located in the power plant. Firstly, the offline PD measurements of these generators have been energized to the star point side and the high voltage coupling capacitor is installed on the high voltage terminal side, according to IEC 60034-27-1. Additionally, the test voltages were applied to the test object with a step voltage profile. To analyze the PD behaviors of the stator winding insulation, the PD characteristics such as the PD pulses, PD magnitude, and phase-resolved PD (PRPD) patterns were monitored and recorded. Besides, the effect of applied test voltage-time, i.e., 1, 3, and 5 minutes, on such characteristics were reported and compared. Finally, the PD behavior of the stator winding insulation of these generators showed clearly different results for PD measured at different recording times. The highly fluctuating PD magnitude and PD pulse shape at the initial duration of the measurement, and then gradually decreases to convergence to a stable charge magnitude as the test-time increases. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, The Study of Polarization and Depolarization Current Measurements on Service-Aged 22 kV XLPE Underground Cables with Presence of Water Trees(2022-01-01) ;Udomluksananon, P.; ;Maneerot, S.; This paper represents the condition assessment of service-aged 22 kV XLPE insulated underground cables. From the investigation, the water trees were detected in the insulation layer. The visual inspection of underground cables reveals the presence of copper carbonate contaminated on the copper tape layer. Some underground cables have the discontinuity of the copper tape layer. To evaluate the insulation condition of the underground cables, the polarization and depolarization current (PDC) measurements were performed on both the service-aged and the new (or unused) cables. The underground cables to experiment with the length of insulation screen equal to 1 m were prepared. In this research, the PDC measurements were performed on different aspects, i.e., the testing voltages (600 V, 800 V, and 1000 V), the testing positions, the effect of the discontinuity of the copper tape layer which occurred during service, the influence of the presence of copper carbonate, and the influence of water trees in XLPE cables. The dielectric response of the underground cables by using polarization and depolarization current measurements can diagnose the problems in service-aged underground cables, but this paper needs more test data for accurate interpretation.