    Item type:Publication,
    Numerical heat transfer study of square duct equipped with novel flapped V-baffles
    (2024-03-01) ; ;
    Skullong, Sompol
    ;
    Promthaisong, Pitak
    ;
    Nakhchi, Mahdi Erfanian
    The paper describes a computational study of heat transfer enhancement inside a square duct with V-shaped flapped baffles located repeatedly on the bottom and top walls for fluid flowing with Reynolds numbers (Re) from 3000 to 21,000. The basic goal of this work is to attain the largest relative Nusselt number (Nu/Nu<inf>0</inf>) whilst maintaining the highest thermal performance to improve energy savings. A finite volume method was used in the computations, along with the Realizable k‒ε turbulent model. The variable baffle parameters considered first in the current simulation were the relative height/blockade ratio (B<inf>R</inf> = 0.05−0.2) and the flap angle of the baffle hole (β = 0° − 90°), while the fixed parameters included the attack angle (α = 60°), hole diameter ratio (d<inf>R</inf> = 0.5), and pitch ratio (P<inf>R</inf> = 0.5). To accomplish this goal, the previously mentioned parameters providing the best thermal performance were investigated further by extending the values of B<inf>R</inf> to 0.25−0.3, d<inf>R</inf> to 0.8 and α to 45°−30°. The simulation results indicate that the jet flowing from the flapped hole, as well as the vortices created by the baffle, can boost heat transfer and friction loss in comparison to the plain duct. In comparison, using a flapped baffle with β > 0° results in less friction loss, a greater thermal enhancement factor (TEF), and a higher Nusselt number than using a baffle with no flap. The first investigation disclosed that for B<inf>R</inf> = 0.2 and β = 20°, the greatest TEF of 2.19 with Nu/Nu<inf>0</inf> of 7.9 times are obtained. The extended study, on the other hand, showed that the highest TEF of roughly 2.49 with Nu/Nu<inf>0</inf> of 8.4 times are seen for α = 45°, d<inf>R</inf> = 0.8, B<inf>R</inf> = 0.25 and β = 20° at lowest Re. Thus, the flapped baffle provides a significant increase in Nu/Nu<inf>0</inf> and TEF over the baffle alone.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Entropy generation and thermal performance of tubular heat exchanger fitted with louvered corner-curved V-baffles
    (2023-02-01) ; ; ;
    Skullong, Sompol
    The current article deals with an experimental study on entropy generation analysis and thermohydraulic performance of a uniform heat-flux tube equipped with louvered corner-curved baffle tape (LCBT). Air was drawn into the inserted tube for the Reynolds number (Re) between 4760 and 29,300. The V-shaped LCBT arranged by V-tip in downstream direction was introduced with three baffle pitch ratios (P<inf>R</inf> = 1–2) and six louver angles (θ = 0–90°) for a fixed attack angle (α) of 30° and baffle height ratio (B<inf>R</inf> = 0.25). The impacts of investigated parameters on the thermal enhancement factor (TEF), Nusselt number (Nu), friction factor (f), and total entropy generation (S˙<inf>gen</inf><sup>′</sup>) were examined. The measurements showed that the LCBT with the smallest values of P<inf>R</inf> = 1, θ = 0° give the largest Nu and f at about 4.4 and 19.2 times above the plain tube values, respectively. However, the greatest TEF around 2.23 was seen for employing the LCBT at P<inf>R</inf> = 1, θ = 45°. The entropy analysis also showed that the S˙<inf>gen</inf><sup>′</sup> is found to decline with the increment of P<inf>R</inf> and θ, whereas the minimal S˙<inf>gen</inf><sup>′</sup>is at P<inf>R</inf> = 1, θ = 0° for lower Re but at P<inf>R</inf> = 1, θ = 45° for higher Re. Furthermore, the Nu and f empirical correlations for employing LCBTs were also proposed.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Aerothermal performance evaluation of a tube mounted with broken V-ribbed twisted tape: Effect of forward/backward arrangement
    (2023-01-01) ;
    Wongcharee, K.
    ;
    Ketain, P.
    ;
    Chamoli, S.
    ;
    An experimental investigation on the aerothermal performance of a heat exchanger tube equipped with newly designed broken V-ribbed twisted tapes (B-VRT), was carried out. In the present work, the heat transfer intensification by a B-VRT can be attributed to greater mixing caused by two flow characteristics: 1) longitudinal vortices from the ribs and 2) swirling flow from the twisted tape. The B-VRT with rib attack angles (α) of 45°, 60°, 75°, and 90°, were tested using air as the test fluid. The experimental results of the tube with B-VRTs in a forward/backward arrangement were compared to those of a plain tube alone and a tube with typical twisted tapes (TT) for Reynolds numbers between 6,000 and 20,000. The results indicated that the tube with the B-VRT having forward facing ribs with α = 45° gave the best performance with Nusselt number ratio (Nu/Nup) of 2.27, a friction factor (f/fp) of 4.4, and an aerothermal performance factor (APF) of 1.38. For the range investigated, the B-VRT offered up to 31.9% higher Nusselt numbers than TT. The B-VRT with the smallest rib attack angle (α) of 45° offered higher aerothermal performance factors than the ones with rib attack angles (α) of 60°, 75°, and 90° by approximately 6.85%, 12.99%, and 20.2%, respectively. The results of the B-VRT with optimum geometry (α = 45°) were benchmarked against those reported in similar published papers. Evidently, the aerothermal performance factors the B-VRT were superior to those of most of other tube inserts, especially at low Reynolds numbers. Finally, within the range of parameters (α, y/W and Re) taken into consideration in this study, correlations of Nu and f were developed to estimate the heat transfer and pressure drop. The correlations for Nu, f, and APF showed acceptable prediction accuracies, with respective deviations of ±4%, ±5.4%, and ±4%.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Heat Transfer Intensification in a Heat Exchanger by Means of Twisted Tapes in Rib and Sawtooth Forms
    (2022-12-01) ;
    Samutpraphut, Boonsong
    ;
    ;
    Chokphoemphun, Suriya
    ;
    Eiamsa-ard, Smith
    This experimental study aimed to intensify the aerothermal performance index (API) in a round tube heat exchanger employing twisted tapes in rib and sawtooth forms (TTRSs) as swirl/vortex flow generators. The TTRSs have a constant twist ratio of 3.0, a constant rib pitch ratio (p/e) of 1.0, and six different sawtooth angles (α = 20°, 30°, 40°, 50°, 60°, and 70°). Experiments were carried out in an open flow using air as the working fluid for Reynolds numbers between 6000 and 20,000 in the current study, which was conducted in a heated tube under conditions of uniform wall heat flux. A typical twisted tape (TT) was also tested for comparison. The experimental results suggest that TTRSs yield Nusselt numbers ranging from 1.42 to 2.10 times of those of a plain tube. TTRSs with larger sawtooth angles (α) offer superior heat transfer. The TTRSs with α = 20°, 30°, 40°, 50°, 60°, and 70° respectively, enhance average Nusselt numbers by 158%, 162%, 166%, 172%, 180%, and 187% with average friction factors of 3.51, 3.55, 3.60, 3.67, 3.75 and 3.82 times higher than a plain tube. Additionally, TTRSs with sawtooth angles (α) of 20°, 30°, 40°, 50°, 60°, and 70° offer APIs in the ranges of 0.99 to 1.19, 1.01 to 1.21, 1.03 to 1.26, 1.05 to 1.31, 1.07 to 1.42, and 1.09 to 1.48, respectively, which are higher than those of the typical twisted tape (TT) by around 5%, 7%, 11%, 16%, 25%, and 31%, respectively. This demonstrates that twisted tapes in rib and sawtooth form (TTRSs), with appropriate geometries, give a promising trade-off between enhanced heat transfer and an increased friction loss penalty.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Thermal performance enhancement of a circular tube fitted with inclined perforated disk inserts
    (2026-03-01)
    Mehta, Rajesh
    ;
    Gupta, Anirudh
    ;
    Kumar, Nitin
    ;
    Eiamsa-ard, Smith
    ;
    Heat exchangers are crucial devices in industries, and enhancing their thermal performance while controlling pressure losses remains a significant challenge. This paper examines the idea that inclined perforated disk (IPD) inserts can be effectively used to improve heat transfer in circular tubes with constant heat flux conditions at acceptable levels of hydraulic penalties. Turbulent airflow with Reynolds numbers (Re) ranging from 5000 to 21,000 was examined in experiments, and three perforation indices (PI = 0.21, 0.24, and 0.27) were tested to determine the effects of hole density on thermal and hydraulic performance. Evidence showed that the Nusselt number (Nu) had been improved by over 86 % compared to plain tubes, with the thermal enhancement factor (TEF) reaching as high as 1.53 at PI = 0.27 and Re = 5000. Particle swarm optimization (PSO) and neural network modelling multi-objective optimization were used to test the results of the experiment and determine the best operating conditions at PI = 0.21. The paper has demonstrated that inclined perforated disk inserts can form a viable passive method for enhancing the efficiency of heat exchangers, as the swirl and jet flow patterns created by the perforations effectively break the thermal boundary layer, thereby increasing the rate of convective heat transfer.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Enhanced thermal effectiveness of square duct with V-type double-baffles: Numerical study
    (2024-09-01) ;
    Sripattanapipat, Somchai
    ;
    ;
    Skullong, Sompol
    ;
    Promthaisong, Pitak
    The article puts forward three-dimensional computational research on heat transmission augmentation within a square channel containing 45<sup>o</sup> V-type double-baffles positioned on the lower and top parts at regular intervals in the turbulence zone for Reynolds numbers (Re) that vary from 3000 to 20,000. The primary goal of this research is to increase the thermal effectiveness and relative Nusselt number (Nu/Nu<inf>0</inf>), in order to conserve energy and reduce the size of the heating or cooling system. The simulations utilize a finite volume approach in common with the SIMPLE algorithm, whereas the turbulent model used is the realizable k–ε. The baffles are designed to be separated vertically for reducing pressure loss. Both single V-baffles and double V-baffles have four relative pitches (PR = 0.4, 0.5, 0.6, and 1.0) and height/blockage ratios (BR = 0.05, 0.1, 0.15, and 0.2), with a fixed attack angle (α) of 45<sup>o</sup>. The computational findings show that both V-baffles are capable of producing the primary vortices, but only the double V-baffles have the ability to provide the impinging streams onto the wall, cooling the region behind the baffles. This suggests that the double V-baffles not only boost heat transmission but also reduce frictional loss. When compared to a single V-baffle, the double ones enhance heat transfer by an average of 1.04–9.94% while decreasing frictional loss by an average of 9.88–31.73%. The thermal effectiveness factor (TEF) of the double V-baffles ranges from 1.03 to 3.21, and its peak value of around 3.21 is for PR = 0.4, BR = 0.05, at lower Re.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Parametric study on thermal performance augmentation of TiO2/water nanofluids flowing a tube contained with dual counter twisted-tapes
    (2024-07-01) ;
    Wongcharee, K.
    ;
    Kunnarak, K.
    ;
    Chokphoemphun, S.
    ;
    Chamoli, S.
    The study of compound heat transfer enhancement technique using dual counter twisted tapes (DCTs) together with TiO<inf>2</inf>/water nanofluids was carried out. The dual twisted tapes in form of counter-swirl tape arrangement were utilized at three twist ratios (y/w = 1.5, 2.0 and 2.5). TiO<inf>2</inf>/water nanofluids having three different volume concentrations (φ = 0.05, 0.10 and 0.15 %) were employed as the testing fluids. The results indicated that heat transfer rate, friction factor and thermal enhancement index rose with decreasing tape twisted ratio and elevating nanofluid concentration. The TiO<inf>2</inf>/water nanofluids applied in the present work offered higher Nu than pure water (the base fluid) by 7.3–10.0 %. The application of DCT with the smallest y/w of 1.5 and TiO<inf>2</inf>/water nanofluids with the largest φ of 0.15 vol% led to the highest thermal enhancement index (TEI) of 1.53, under the same pumping power criteria. Additionally, the k-nearest neighbor (k-NN) and artificial neural network (ANN) were developed to predict the thermal enhancement index (TEI). It was found that the k-NN and ANN models provided maximum R<sup>2</sup> values of 0.919 and 0.992 f, respectively.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Heat transfer performance evaluation of a solar air heater duct with multiple tapered V-baffles
    (2025-12-01) ;
    Kaewkosum, P.
    ;
    Woncharee, K.
    ;
    Keaitnukul, W.
    ;
    Maruyama, N.
    This report aims to study the heat transfer enhancement, pressure loss characteristics, and thermal performance of a channel equipped with multiple tapered V-shaped baffles (MTVBs). The effects of up-facing and down-facing orientations, converging (C) and diverging(D) configurations, variations in the taper ratio (e<inf>CR</inf> and e<inf>DR</inf> = 0.0 and 0.5), and Reynolds number (6000 ≤ Re ≤ 24,000) are examined. The performance of UF-C-MTVBs, DF-C-MTVBs, UF-D-MTVBs, and DF-D-MTVBs is analyzed and compared with that of the conventional transverse baffles (TBs) and MVBs (e<inf>DR</inf> = 1.0). The experimental setup maintained a constant attack angle (α) of 45°, pitch ratio (p/H) of 1.5, width-shaped ratio (W<inf>b</inf>/W) of 0.25, and blockage ratio (e/H) of 0.3. Tests were conducted at a fixed Prandtl number of 0.71, and a thermochromic liquid crystal sheet was utilized to assess the local Nusselt number distribution on the wall installed with UF-C-MTVBs, DF-C-MTVBs, UF-D-MTVBs, and DF-D-MTVBs. The results reveal that the channel with MVBs (e<inf>DR</inf> = 1.0) achieves the greatest heat transfer rate, with a Nu/Nu<inf>s</inf> ratio of up to 4.37 while a f/f<inf>s</inf> ratio reaching 48.12. In contrast, D-MTVBs at e<inf>DR</inf> = 0.0, despite having a lower Nu/Nu<inf>s</inf> ratio (maximum 3.87), attain the maximum thermal performance of 1.39 at Re = 6000, owing to their optimized design that effectively enhances heat transfer while minimizing pressure drop.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Performance of a heat exchanger with compound inclined circular-rings and twisted tapes
    (2022-09-01) ;
    Samruaisin, P.
    ;
    ;
    Ruengpayungsak, K.
    ;
    Eiamsa-Ard, P.
    Optimization was done of the aerothermal performance factor (η) of a tube into which a combination of inclined circular-rings (ICRs) and twisted-tapes (TTs) were installed. The key contribution of this research is determination of the appropriate ICR and TT sizes to produce the best heat exchanger performance. An ICR's purpose is to produce counter-rotating vortices, whereas the TT's role is to create swirl flow within a tube to improve turbulence and transfer cold fluid from the core region to the heated-wall zone. The influence of circular-ring inclination angle (α = 30o, 45o, 60o and 90o), number of twisted tapes (H = 2, 4, and 6) and twist ratios (TR = 1.0, 2.0, and 3.0) on heat transfer and pressure losses were assessed to determine an optimum η condition. The heat transfer and friction factor tend to increase with H values and decreasing TR. The heat transfer of ICRs together with TTs is higher than in a plain tube by up to 128.7% and 155.3%, respectively, while it is better than the transverse circular-ring (α = 90o) and twisted-tape by up to 116.9% and 146.5%, respectively. Furthermore, due to moderate heat transfer and low pressure losses, a maximal η of 1.66 was achieved for α = 30o, H = 2 and TR = 3.0 within the examined range.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Influence of sawtooth twisted tape on thermal enhancement of heat exchanger tube
    (2023-03-01)
    Samutpraphut, Boonsong
    ;
    Eiamsa-ard, Smith
    ;
    ; ;
    Maruyama, Naoki
    This article employs sawtooth twisted tapes to generate swirling flow and interrupted flowing disturbance in order to increase the level of heat transfer rate. The influences of the sawtooth twisted tape (S-TT) on enhanced heat transfer rate, friction factor and aerothermal performance index (API) behaviors are analyzed. The sawtooth twisted tapes (S-TTs) possessing constant pitch/twist ratio (y//W) of 3.0 and six sawtooth angles (α) of 20°, 30°, 40°, 50°, 60°, and 70° are assessed. Considering turbulent flow using air as the testing fluid, experiments were investigated at 6,000 < Re < 20,000 under boundary conditions of constant heat flux. According to the experimental findings, sawtooth twisted tape (S-TT) improves heat transfer rate and raises pressure loss with varying rates based on sawtooth angles (α). With the sawtooth twisted tape (S-TT) and 70° sawtooth angles, the optimum API of 1.33 is attained, while Nusselt number and friction factor are 32 and 0.135 at Re = 6,000. The recommended sawtooth twisted tape (S-TT) yields a highest Nusselt number of 78, which is 1.6 times greater than the typical twisted tape (TT) and 1.1 times greater than the plain tube. The combination of the TT and sawtooth patterns can be beneficial in terms of boosting heat transfer rate and API relating coupling of swirling flow and interrupted flowing disruption effects since the sawtooth twisted tape (S-TT) offers superior performance than the TT. Additionally, the heat exchanger tubes fitted with sawtooth twisted tape (S-TT) at sawtooth angles (α) of 20°, 30°, 40°, 50°, 60°, and 70° gain greater Nusselt number than the plain tube up to 158.3%, 162.2%, 166.1%, 171.7%, 179.7% and 186.2%, respectively.