Item type:Publication, Heat Transfer Intensification in a Heat Exchanger by Means of Twisted Tapes in Rib and Sawtooth Forms(2022-12-01); ;Samutpraphut, Boonsong; ;Chokphoemphun, SuriyaEiamsa-ard, SmithThis experimental study aimed to intensify the aerothermal performance index (API) in a round tube heat exchanger employing twisted tapes in rib and sawtooth forms (TTRSs) as swirl/vortex flow generators. The TTRSs have a constant twist ratio of 3.0, a constant rib pitch ratio (p/e) of 1.0, and six different sawtooth angles (α = 20°, 30°, 40°, 50°, 60°, and 70°). Experiments were carried out in an open flow using air as the working fluid for Reynolds numbers between 6000 and 20,000 in the current study, which was conducted in a heated tube under conditions of uniform wall heat flux. A typical twisted tape (TT) was also tested for comparison. The experimental results suggest that TTRSs yield Nusselt numbers ranging from 1.42 to 2.10 times of those of a plain tube. TTRSs with larger sawtooth angles (α) offer superior heat transfer. The TTRSs with α = 20°, 30°, 40°, 50°, 60°, and 70° respectively, enhance average Nusselt numbers by 158%, 162%, 166%, 172%, 180%, and 187% with average friction factors of 3.51, 3.55, 3.60, 3.67, 3.75 and 3.82 times higher than a plain tube. Additionally, TTRSs with sawtooth angles (α) of 20°, 30°, 40°, 50°, 60°, and 70° offer APIs in the ranges of 0.99 to 1.19, 1.01 to 1.21, 1.03 to 1.26, 1.05 to 1.31, 1.07 to 1.42, and 1.09 to 1.48, respectively, which are higher than those of the typical twisted tape (TT) by around 5%, 7%, 11%, 16%, 25%, and 31%, respectively. This demonstrates that twisted tapes in rib and sawtooth form (TTRSs), with appropriate geometries, give a promising trade-off between enhanced heat transfer and an increased friction loss penalty. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Compound heat transfer enhancement of a dimpled tube with a twisted tape swirl generator(2009-08-01); ;Eiamsa-ard, Petpices ;Wongcharee, KhwanchitEiamsa-ard, SmithFriction and compound heat transfer behaviors in a dimpled tube fitted with a twisted tape swirl generator are investigated experimentally using air as working fluid. The effects of the pitch and twist ratio on the average heat transfer coefficient and the pressure loss are determined in a circular tube with the fully developed flow for the Reynolds number in the range of 12,000 to 44,000. The experiments are performed using two dimpled tubes with different pitch ratios of dimpled surfaces (PR = 0.7 and 1.0) and three twisted tapes with three different twist ratios (y/w = 3, 5, and 7). Experiments using plain tube and dimpled tube acting alone are also carried out for comparison. The experimental results reveal that both heat transfer coefficient and friction factor in the dimpled tube fitted with the twisted tape, are higher than those in the dimple tube acting alone and plain tube. It is also found that the heat transfer coefficient and friction factor in the combined devices increase as the pitch ratio (PR) and twist ratio (y/w) decrease. In addition, an empirical correlation based on the experimental results of the present study is sufficiently accurate for prediction the heat transfer (Nu) and friction factor (f) behaviors. © 2009 Elsevier Ltd. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal performance enhancement of a circular tube fitted with inclined perforated disk inserts(2026-03-01) ;Mehta, Rajesh ;Gupta, Anirudh ;Kumar, Nitin ;Eiamsa-ard, SmithHeat exchangers are crucial devices in industries, and enhancing their thermal performance while controlling pressure losses remains a significant challenge. This paper examines the idea that inclined perforated disk (IPD) inserts can be effectively used to improve heat transfer in circular tubes with constant heat flux conditions at acceptable levels of hydraulic penalties. Turbulent airflow with Reynolds numbers (Re) ranging from 5000 to 21,000 was examined in experiments, and three perforation indices (PI = 0.21, 0.24, and 0.27) were tested to determine the effects of hole density on thermal and hydraulic performance. Evidence showed that the Nusselt number (Nu) had been improved by over 86 % compared to plain tubes, with the thermal enhancement factor (TEF) reaching as high as 1.53 at PI = 0.27 and Re = 5000. Particle swarm optimization (PSO) and neural network modelling multi-objective optimization were used to test the results of the experiment and determine the best operating conditions at PI = 0.21. The paper has demonstrated that inclined perforated disk inserts can form a viable passive method for enhancing the efficiency of heat exchangers, as the swirl and jet flow patterns created by the perforations effectively break the thermal boundary layer, thereby increasing the rate of convective heat transfer. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Turbulent flow heat transfer and pressure loss in a double pipe heat exchanger with louvered strip inserts(2008-02-01) ;Eiamsa-ard, Smith ;Pethkool, Somsak; In the present work, heat transfer and friction characteristics were experimentally investigated, employing louvered strips inserted in a concentric tube heat exchanger. The louvered strip was inserted into the tube to generate turbulent flow which helped to increase the heat transfer rate of the tube. The flow rate of the tube was in a range of Reynolds number between 6000 and 42,000. The turbulent flow devices were consisted of (1) the louvered strips with forward or backward arrangements, and (2) the louvered strip with various inclined angles (θ = 15°, 25° and 30°), inserted in the inner tube of the heat exchanger. In the experiment, hot water was flowed through the inner tube whereas cold water was flowed in the annulus. The experimental data obtained were compared with those from plain tubes of published data. Experimental results confirmed that the use of louvered strips leads to a higher heat transfer rate over the plain tube. The increases in average Nusselt number and friction loss for the inclined forward louvered strip were 284% and 413% while those for the backward louvered strip were 263% and 233% over the plain tube, respectively. In addition, the use of the louvered strip with backward arrangement leads to better overall enhancement ratio than that with forward arrangement around 9% to 24%. © 2007 Elsevier Ltd. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Experimental investigation of heat transfer and flow friction in a circular tube fitted with regularly spaced twisted tape elements(2006-12-01) ;Eiamsa-ard, Smith; Experimental investigation of heat transfer and friction factor characteristics in a double pipe heat exchanger fitted with regularly spaced twisted tape elements, were studied. The inner and outer diameters of the inner tube are 50.6 and 25.8 mm, respectively and cold and hot water were used as working fluids in shell side and tube side. The twisted tapes were made of the stainless steel strip with thickness of 1 mm and the length of 1500 mm. They were inserted in the test tube section in two different cases: (1) full-length typical twisted tape at different twisted ratios (y = 6.0 and 8.0), and (2) twisted tape with various free space ratios (S = 1.0, 2.0, and 3.0). The results, obtained from the tube with twisted tape insert, were compared with those without twisted tape. The results show that the heat transfer coefficient increased with twist ratio (y). Whereas the increase in the free space ratio (S) would improve both the heat transfer coefficient and friction factor. The results from each case were correlated for Nusselt number and friction factor. Subsequently, the predicted Nusselt number and friction factor from the correlations were plotted to compare with the experimental data. It was found that Nusselt number was within ± 15% and ± 10% for friction factor. © 2006 Elsevier Ltd. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Influence of sawtooth twisted tape on thermal enhancement of heat exchanger tube(2023-03-01) ;Samutpraphut, Boonsong ;Eiamsa-ard, Smith; ; Maruyama, NaokiThis article employs sawtooth twisted tapes to generate swirling flow and interrupted flowing disturbance in order to increase the level of heat transfer rate. The influences of the sawtooth twisted tape (S-TT) on enhanced heat transfer rate, friction factor and aerothermal performance index (API) behaviors are analyzed. The sawtooth twisted tapes (S-TTs) possessing constant pitch/twist ratio (y//W) of 3.0 and six sawtooth angles (α) of 20°, 30°, 40°, 50°, 60°, and 70° are assessed. Considering turbulent flow using air as the testing fluid, experiments were investigated at 6,000 < Re < 20,000 under boundary conditions of constant heat flux. According to the experimental findings, sawtooth twisted tape (S-TT) improves heat transfer rate and raises pressure loss with varying rates based on sawtooth angles (α). With the sawtooth twisted tape (S-TT) and 70° sawtooth angles, the optimum API of 1.33 is attained, while Nusselt number and friction factor are 32 and 0.135 at Re = 6,000. The recommended sawtooth twisted tape (S-TT) yields a highest Nusselt number of 78, which is 1.6 times greater than the typical twisted tape (TT) and 1.1 times greater than the plain tube. The combination of the TT and sawtooth patterns can be beneficial in terms of boosting heat transfer rate and API relating coupling of swirling flow and interrupted flowing disruption effects since the sawtooth twisted tape (S-TT) offers superior performance than the TT. Additionally, the heat exchanger tubes fitted with sawtooth twisted tape (S-TT) at sawtooth angles (α) of 20°, 30°, 40°, 50°, 60°, and 70° gain greater Nusselt number than the plain tube up to 158.3%, 162.2%, 166.1%, 171.7%, 179.7% and 186.2%, respectively. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermodynamic performance analysis of a round tube fitted with gradient quadruple twisted tapes(2026-03-01) ;Samruaisin, Prachya ;Liengsirikul, Sathaporn; ; Chamoli, SunilAir-cooled heat exchangers employing twisted-tape passive inserts exist in many forms; however, designing tapes that are practical to manufacture while enhancing heat transfer without incurring excessive pressure drop remains challenging. This study therefore introduces gradient quadruple twisted tapes (GQTT), which gradually vary the pitch across four tapes to control swirl and mix along the tube. In addition, the turn count changes in steps along the four tapes, which triggers extra turbulence near each change and keeps the flow well mixed downstream. This simple and manufacturable pattern aims to boost heat transfer while keeping the added friction under control. Our objective is to evaluate whether GQTT can improve overall performance while keeping the pressure drop within a practical range, in comparison with a plain tube and a constant-turn tape. A realizable k-ε turbulence model, rigorously validated against benchmark data, was applied to eight GQTT variants and benchmarked against a plain tube and a constant-turn tape for Reynolds numbers (Re) between 5000 and 19,000. Spatial second-order schemes, grid-independence testing, and strict residual criteria ensured solution accuracy. Among the candidates, the descending-opposite-pitch configuration (Ds-OPSD) consistently delivered the highest performance. First-law analysis reveals a peak thermal performance factor (TPF) of 1.42 at Re = 5000, equating to a 42 % gain in overall thermo-hydraulic efficiency over the plain tube, with the Nusselt number (Nu) climbing from 57.5 to 100 across the examined Re window. Second-law metrics corroborate this superiority. At the same Re of peak TPF, the Ds-OPSD cuts exergy destruction from 291.4 to 62 W (≈79 % reduction versus the plain tube and ≈22 % versus the constant-turn tape). Total entropy generation remains minimal and nearly constant (S<inf>total</inf> ≈ 0.206–0.212), while the Bejan number stays high (≈0.999–0.971), indicating that the enhancement is achieved without excessive frictional penalties. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal characteristics in a heat exchanger tube fitted with dual twisted tape elements in tandem(2010-01-01) ;Eiamsa-ard, Smith; ;Eiamsa-ard, PetpicesThe paper presents a comparative investigation of enhanced heat transfer and pressure loss by insertion of single twisted tape, full-length dual and regularly-spaced dual twisted tapes as swirl generators, in a round tube under axially uniform wall heat flux (UHF) conditions. The investigation encompassed the Reynolds number based on the inlet tube diameter (D) ranging from 4000 to 19,000. The experiments are performed using single twisted tapes and full-length dual twisted tapes with three different twist ratios (y/w = 3.0, 4.0 and 5.0) and also regularly-spaced dual twisted tapes with three different space ratios (s/D = 0.75, 1.5 and 2.25). The effects of major parameters on heat transfer and friction factor are discussed and the results from both single and dual twisted tape inserts are compared with those from the plain tube. The result shows that the heat transfer of the tube with dual twisted tapes is higher than that of the plain tube with/without single twisted tape insert. For both single twisted tape and full-length dual twisted tapes, Nusselt number (Nu) and friction factor (f) tend to increase with decreasing twist ratio (y/w). The average Nusselt number and friction factor in the tube fitted with the full-length dual twisted tapes at y/w = 3.0, 4.0 and 5.0, are respectively 146%, 135% and 128%; and 2.56, 2.17 and 1.95 times of those in the plain tube. For the regularly-spaced dual twisted tapes, the heat transfer rate is decreased with increasing space ratio (s/D). The average Nusselt numbers in the tube fitted with the regularly-spaced dual twisted tapes (s/D) of 0.75, 1.5 and 2.25 are respectively, 140%, 137% and 133% of that in the plain tube. With the similar trend mentioned above, all dual twisted tapes with free spacing yield lower heat transfer enhancement in comparison with the full-length dual twisted tapes (s/D = 0.0). © 2009 Elsevier Ltd. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Evaluation of aerothermal performance of a round tube with regularly-spaced multi-channel twisted tape elements installed(2024-06-01) ;Phila, Arnut; ; ;Bhattacharyya, SuvanjanNaphon, PaisarnThis article presents a study of aerothermal performance of tubes with regularly-spaced multi-channel twisted tape elements (RS-MTT) installed. This research aimed to find the proper design RS-MTTs that induce swirl flow which potentially improves fluid mixing between the core fluid and the fluid near the tube wall, thereby accelerating the heat transfer rate. Additionally, the effects of Reynolds numbers and free-spacing ratios (s/y) on heat transfer, friction loss, and thermal performance behaviors were examined. The RS-MTTs having different free-spacing ratios (s/y) of 0.0, 0.25, 0.5, 0.75, and 1.0 were tested. Air was utilized as the testing fluid in experiments with Reynolds numbers (Re) spanning from 6000 to 20,000. The utilization of RS-MTTs with s/y = 0.0, 0.25, 0.5, 0.75, and 1.0 augmented heat transfer rates up to 1.74, 1.80, 1.85, 1.90, and 2.15 times given by the plain tube alone while the friction factors increased by 4.22, 4.61, 3.87, and 4.05 times, respectively. At the lowest Reynolds number of 6000, the thermal enhancement factors of the tube containing the RS-MTTs with s/y = 0.0, 0.25, 0.5, 0.75, and 1.0 reached the maximum values of 1.42, 1.35, 1.31, 1.27, and 1.23, respectively. Among the RS-MTTs tested, the RS-MTT with s/y = 0.0 showed the best thermal enhancement factor of 4.56%, corresponding to the heat transfer augmented of 11.52% with a friction penalty of 8.71%. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Enhanced Heat Transfer of a Heat Exchanger Tube Installed with V-Shaped Delta-Wing Baffle Turbulators(2023-07-01) ;Samruaisin, Prachya ;Maza, Rangsan; ; Maruyama, NaokiThe influences of V-shaped delta-wing baffles on the thermohydraulic performance characteristics in a round tube were experimentally tested. The V-shaped delta-wing baffles having a set number of wings (N = 4, 6, and 8) were comparatively tested. The V-shaped delta-wing baffles with various pitch ratios of P/D = 2.0, 2.5, and 3.0 were thoroughly fitted inside a tube. In the present work, the baffles were responsible for both the recirculation/reverse flow behind the solid baffle and the longitudinal vortex flow behind the V-shaped wing. The V-shaped winged baffles with N = 8 produced high heat transfer rates by promoting the development of reverse and vortex flows. These currents aid in fluid mixing between the two streams. Experimental results suggested that utilizing V-shaped delta-wing baffles having N = 4, 6, and 8 led to Nusselt number enhancement of up to 97–105.6%, 105.8–127.8% and 114.8–138.9%, respectively. When N was 8, the V-shaped wings baffles created additional multi vortex flows, which resulted in some fluid mixing between the vortex and the reverse flow. It was discovered that a greater turbulent intensity is imparted to the flow that was occurring between the V-shaped delta-wing baffles, which led to an increase in the rate of heat transfer when the pitch ratio was decreased. The increase in Nusselt number was up to 118.26–151.3% more than it was in a tube with the lowest pitch ratio (P/D = 2.0). It was also found that the baffles with N = 8 wings and P/D = 3.0 offered a maximum aerothermal performance factor (APF) of 1.01. Furthermore, the V-shaped delta-wing baffles have the potential for energy savings at low Re ≤ 6000, indicated by the APF beyond unity.