    Heat transfer augmentation in a wedge-ribbed channel using winglet vortex generators
    (2010-02-01)
    Chompookham, Teerapat
    ;
    ; ;
    Experimental investigations have been carried out to study the effect of combined wedge ribs and winglet type vortex generators (WVGs) on heat transfer and friction loss behaviors for turbulent airflow through a constant heat flux channel. To create a reverse flow in the channel, two types of wedge (right-triangle) ribs are introduced: wedge ribs pointing downstream and pointing upstream. The arrangements of both rib types placed inside the opposite channel walls are in-line and staggered arrays. To generate longitudinal vortex flows through the tested section, two pairs of the WVGs with the attack angle of 60° are mounted on the test channel entrance. The test channel has an aspect ratio, AR = 10 and height, H = 30 mm with a rib height, e/H = 0.2 and rib pitch, P/H = 1.33. The flow rate in terms of Reynolds numbers is based on the inlet hydraulic diameter of the channel ranging from 5000 to 22,000. The presence of the combined ribs and the WVGs shows the significant increase in heat transfer rate and friction loss over the smooth channel. The Nusselt number and friction factor values obtained from combined the ribs and the WVGs are found to be much higher than those from the ribs/WVGs alone. In conjunction with the WVGs, the in-line wedge pointing downstream provides the highest increase in both the heat transfer rate and the friction factor while the staggered wedge pointing upstream yields the best thermal performance. © 2009 Elsevier Ltd. All rights reserved.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Numerical investigation of laminar heat transfer in a square channel with 45° inclined baffles
    (2010-02-01) ;
    Sripattanapipat, S.
    ;
    Tamna, S.
    ;
    ;
    A numerical investigation of laminar periodic flow and heat transfer in a three-dimensional isothermal-wall square channel fitted with 45° inclined baffles on one channel wall is carried out in the present work. The finite volume method is introduced and the SIMPLE algorithm has been implemented for all computations. The fluid flow and heat transfer characteristics are presented for Reynolds numbers ranging from 100 to 1200. The 45° baffle mounted only on the lower channel wall has a height of b and an axial pitch length (L) equal to channel height (H). Effects of flow blockage ratios, BR = b/H = 0.1-0.5, on heat transfer and pressure loss in the square channel are examined and also compared with the typical case of the transverse baffle (or 90° baffle). It is found that apart from the rise of Reynolds number, the increase in the blockage ratio with the attack angle (α) of 45° results in considerable increases in the Nusselt number and friction factor values. The use of the 45° baffle can help to generate a streamwise main vortex flow throughout the channel leading to fast and chaotic mixing of flow between the core and the wall regions. In addition, the computational results reveal that the significant increase in heat transfer rate is due to impingement jets induced by a longitudinal vortex pair (P-vortex) of flow, appearing on the upper, lower and baffle trailing end side walls. The appearance of vortex-induced impingement flows created by the baffles leads to the maximum thermal enhancement factor of about 2.2 at BR = 0.4 and Re = 1200. The enhancement factor of the 45° baffle investigated is found to be higher than that of the 90° baffle for all Reynolds numbers and baffle heights. © 2009 Elsevier Ltd. All rights reserved.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Numerical heat transfer study of square duct equipped with novel flapped V-baffles
    (2024-03-01) ; ;
    Skullong, Sompol
    ;
    Promthaisong, Pitak
    ;
    Nakhchi, Mahdi Erfanian
    The paper describes a computational study of heat transfer enhancement inside a square duct with V-shaped flapped baffles located repeatedly on the bottom and top walls for fluid flowing with Reynolds numbers (Re) from 3000 to 21,000. The basic goal of this work is to attain the largest relative Nusselt number (Nu/Nu<inf>0</inf>) whilst maintaining the highest thermal performance to improve energy savings. A finite volume method was used in the computations, along with the Realizable k‒ε turbulent model. The variable baffle parameters considered first in the current simulation were the relative height/blockade ratio (B<inf>R</inf> = 0.05−0.2) and the flap angle of the baffle hole (β = 0° − 90°), while the fixed parameters included the attack angle (α = 60°), hole diameter ratio (d<inf>R</inf> = 0.5), and pitch ratio (P<inf>R</inf> = 0.5). To accomplish this goal, the previously mentioned parameters providing the best thermal performance were investigated further by extending the values of B<inf>R</inf> to 0.25−0.3, d<inf>R</inf> to 0.8 and α to 45°−30°. The simulation results indicate that the jet flowing from the flapped hole, as well as the vortices created by the baffle, can boost heat transfer and friction loss in comparison to the plain duct. In comparison, using a flapped baffle with β > 0° results in less friction loss, a greater thermal enhancement factor (TEF), and a higher Nusselt number than using a baffle with no flap. The first investigation disclosed that for B<inf>R</inf> = 0.2 and β = 20°, the greatest TEF of 2.19 with Nu/Nu<inf>0</inf> of 7.9 times are obtained. The extended study, on the other hand, showed that the highest TEF of roughly 2.49 with Nu/Nu<inf>0</inf> of 8.4 times are seen for α = 45°, d<inf>R</inf> = 0.8, B<inf>R</inf> = 0.25 and β = 20° at lowest Re. Thus, the flapped baffle provides a significant increase in Nu/Nu<inf>0</inf> and TEF over the baffle alone.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Performance assessment in a heat exchanger tube with opposite/parallel wing twisted tapes
    (2015-01-01)
    Eiamsa-Ard, S.
    ;
    ;
    The thermohydraulic performance in a tube containing a modified twisted tape with alternate-axes and wing arrangements is reported. This work aims to investigate the effects of wing arrangements (opposite (O) and parallel (P) wings) at different wing shapes (triangle (Tri), rectangular (Rec), and trapezoidal (Tra) wings) and on the thermohydraulic performance characteristics. The obtained results show that wing twisted tapes with all wing shape arrangements (O-Tri/O-Rec/O-Tra/P-Tri/P-Rec/P-Tra) give superior thermohydraulic performance and heat transfer rate to the typical twisted tape. In addition, the tapes with opposite wing arrangement of O-Tra, O-Rec, and O-Tri give superior thermohydraulic performances to those with parallel wing arrangement of P-Tra, P-Rec, and P-Tri around 2.7%, 3.5%, and 3.2%, respectively.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Entropy generation and thermal performance of tubular heat exchanger fitted with louvered corner-curved V-baffles
    (2023-02-01) ; ; ;
    Skullong, Sompol
    The current article deals with an experimental study on entropy generation analysis and thermohydraulic performance of a uniform heat-flux tube equipped with louvered corner-curved baffle tape (LCBT). Air was drawn into the inserted tube for the Reynolds number (Re) between 4760 and 29,300. The V-shaped LCBT arranged by V-tip in downstream direction was introduced with three baffle pitch ratios (P<inf>R</inf> = 1–2) and six louver angles (θ = 0–90°) for a fixed attack angle (α) of 30° and baffle height ratio (B<inf>R</inf> = 0.25). The impacts of investigated parameters on the thermal enhancement factor (TEF), Nusselt number (Nu), friction factor (f), and total entropy generation (S˙<inf>gen</inf><sup>′</sup>) were examined. The measurements showed that the LCBT with the smallest values of P<inf>R</inf> = 1, θ = 0° give the largest Nu and f at about 4.4 and 19.2 times above the plain tube values, respectively. However, the greatest TEF around 2.23 was seen for employing the LCBT at P<inf>R</inf> = 1, θ = 45°. The entropy analysis also showed that the S˙<inf>gen</inf><sup>′</sup> is found to decline with the increment of P<inf>R</inf> and θ, whereas the minimal S˙<inf>gen</inf><sup>′</sup>is at P<inf>R</inf> = 1, θ = 0° for lower Re but at P<inf>R</inf> = 1, θ = 45° for higher Re. Furthermore, the Nu and f empirical correlations for employing LCBTs were also proposed.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Aerothermal performance evaluation of a tube mounted with broken V-ribbed twisted tape: Effect of forward/backward arrangement
    (2023-01-01) ;
    Wongcharee, K.
    ;
    Ketain, P.
    ;
    Chamoli, S.
    ;
    An experimental investigation on the aerothermal performance of a heat exchanger tube equipped with newly designed broken V-ribbed twisted tapes (B-VRT), was carried out. In the present work, the heat transfer intensification by a B-VRT can be attributed to greater mixing caused by two flow characteristics: 1) longitudinal vortices from the ribs and 2) swirling flow from the twisted tape. The B-VRT with rib attack angles (α) of 45°, 60°, 75°, and 90°, were tested using air as the test fluid. The experimental results of the tube with B-VRTs in a forward/backward arrangement were compared to those of a plain tube alone and a tube with typical twisted tapes (TT) for Reynolds numbers between 6,000 and 20,000. The results indicated that the tube with the B-VRT having forward facing ribs with α = 45° gave the best performance with Nusselt number ratio (Nu/Nup) of 2.27, a friction factor (f/fp) of 4.4, and an aerothermal performance factor (APF) of 1.38. For the range investigated, the B-VRT offered up to 31.9% higher Nusselt numbers than TT. The B-VRT with the smallest rib attack angle (α) of 45° offered higher aerothermal performance factors than the ones with rib attack angles (α) of 60°, 75°, and 90° by approximately 6.85%, 12.99%, and 20.2%, respectively. The results of the B-VRT with optimum geometry (α = 45°) were benchmarked against those reported in similar published papers. Evidently, the aerothermal performance factors the B-VRT were superior to those of most of other tube inserts, especially at low Reynolds numbers. Finally, within the range of parameters (α, y/W and Re) taken into consideration in this study, correlations of Nu and f were developed to estimate the heat transfer and pressure drop. The correlations for Nu, f, and APF showed acceptable prediction accuracies, with respective deviations of ±4%, ±5.4%, and ±4%.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Heat Transfer Intensification in a Heat Exchanger by Means of Twisted Tapes in Rib and Sawtooth Forms
    (2022-12-01) ;
    Samutpraphut, Boonsong
    ;
    ;
    Chokphoemphun, Suriya
    ;
    Eiamsa-ard, Smith
    This experimental study aimed to intensify the aerothermal performance index (API) in a round tube heat exchanger employing twisted tapes in rib and sawtooth forms (TTRSs) as swirl/vortex flow generators. The TTRSs have a constant twist ratio of 3.0, a constant rib pitch ratio (p/e) of 1.0, and six different sawtooth angles (α = 20°, 30°, 40°, 50°, 60°, and 70°). Experiments were carried out in an open flow using air as the working fluid for Reynolds numbers between 6000 and 20,000 in the current study, which was conducted in a heated tube under conditions of uniform wall heat flux. A typical twisted tape (TT) was also tested for comparison. The experimental results suggest that TTRSs yield Nusselt numbers ranging from 1.42 to 2.10 times of those of a plain tube. TTRSs with larger sawtooth angles (α) offer superior heat transfer. The TTRSs with α = 20°, 30°, 40°, 50°, 60°, and 70° respectively, enhance average Nusselt numbers by 158%, 162%, 166%, 172%, 180%, and 187% with average friction factors of 3.51, 3.55, 3.60, 3.67, 3.75 and 3.82 times higher than a plain tube. Additionally, TTRSs with sawtooth angles (α) of 20°, 30°, 40°, 50°, 60°, and 70° offer APIs in the ranges of 0.99 to 1.19, 1.01 to 1.21, 1.03 to 1.26, 1.05 to 1.31, 1.07 to 1.42, and 1.09 to 1.48, respectively, which are higher than those of the typical twisted tape (TT) by around 5%, 7%, 11%, 16%, 25%, and 31%, respectively. This demonstrates that twisted tapes in rib and sawtooth form (TTRSs), with appropriate geometries, give a promising trade-off between enhanced heat transfer and an increased friction loss penalty.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Thermal characterization in a circular tube fitted with inclined horseshoe baffles
    (2015-01-22) ;
    Tamna, Sombat
    ;
    ;
    In the present study, the influence of inclined horseshoes baffles placed repeatedly in a tubular heat exchanger on heat transfer rate, friction factor and thermal enhancement factor are experimentally determined. The horseshoe baffle elements with an inclination angle of 20° were inserted periodically into the test tube at three different baffle-pitch ratios (P<inf>R</inf> = 0.5, 1.0 and 2) and -width or blockage ratios (B<inf>R</inf> = 0.1, 0.15 and 0.2). The experiment was conducted in the test tube having a uniform heat-fluxed wall by varying turbulent airflow to obtain Reynolds number in a range of 5300-24,000. The experimental results revealed that the tube fitted with inclined horseshoes baffles provides considerable improvement of the heat transfer rate over the plain tube around 92-208% while the friction factor is increased at about 1.76-6.37 times. To access the real benefits for the inclined horseshoes baffles inserted in plain tube, thermal performance factor is examined and found to be in the range of 1.34-1.92 at which the maximum obtained at P<inf>R</inf> = 0.5 and B<inf>R</inf> = 0.1 is considerably higher than that for published inserted devices. Correlations for Nusselt number and friction factor for the oblique horseshoe-baffled tube are also proposed.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Compound heat transfer enhancement of a dimpled tube with a twisted tape swirl generator
    (2009-08-01) ;
    Eiamsa-ard, Petpices
    ;
    Wongcharee, Khwanchit
    ;
    Eiamsa-ard, Smith
    Friction and compound heat transfer behaviors in a dimpled tube fitted with a twisted tape swirl generator are investigated experimentally using air as working fluid. The effects of the pitch and twist ratio on the average heat transfer coefficient and the pressure loss are determined in a circular tube with the fully developed flow for the Reynolds number in the range of 12,000 to 44,000. The experiments are performed using two dimpled tubes with different pitch ratios of dimpled surfaces (PR = 0.7 and 1.0) and three twisted tapes with three different twist ratios (y/w = 3, 5, and 7). Experiments using plain tube and dimpled tube acting alone are also carried out for comparison. The experimental results reveal that both heat transfer coefficient and friction factor in the dimpled tube fitted with the twisted tape, are higher than those in the dimple tube acting alone and plain tube. It is also found that the heat transfer coefficient and friction factor in the combined devices increase as the pitch ratio (PR) and twist ratio (y/w) decrease. In addition, an empirical correlation based on the experimental results of the present study is sufficiently accurate for prediction the heat transfer (Nu) and friction factor (f) behaviors. © 2009 Elsevier Ltd. All rights reserved.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Heat transfer augmentation by helically twisted tapes as swirl and turbulence promoters
    (2012-10-01)
    Eiamsa-ard, S.
    ;
    Yongsiri, K.
    ;
    Nanan, K.
    ;
    This paper describes heat transfer enhancement attributed to helically twisted tapes (HTTs). Each helically twisted tape was fabricated by twisting a straight tape to form a typical twisted tape then bending the twisted tape into a helical shape. The experiments were performed using HTTs with three twist ratios (y/. W) of 2, 2.5 and 3, three helical pitch ratios (p/. D) of 1, 1.5 and 2 for Reynolds number between 6000 and 20,000. The conventional helical tape (CHT) was also tested for comparison. The obtained results reveal that at similar conditions (y/. W and . p/. D), HTTs give lower Nusselt number and friction but higher thermal performance factor than CHTs. Heat transfer rate and friction factor increase as the tape twist ratio and helical pitch ratio decrease, while the thermal performance shows opposite trend. In the present range, the highest thermal performance factor of 1.29 is achieved by utilizing the tape with the largest twist ratio (y/. W=3) and helical pitch ratio (p/. D=2) at Reynolds number of 6000. © 2012 Elsevier B.V.