    Numerical investigation of laminar heat transfer in a square channel with 45° inclined baffles
    (2010-02-01) ;
    Sripattanapipat, S.
    ;
    Tamna, S.
    ;
    ;
    A numerical investigation of laminar periodic flow and heat transfer in a three-dimensional isothermal-wall square channel fitted with 45° inclined baffles on one channel wall is carried out in the present work. The finite volume method is introduced and the SIMPLE algorithm has been implemented for all computations. The fluid flow and heat transfer characteristics are presented for Reynolds numbers ranging from 100 to 1200. The 45° baffle mounted only on the lower channel wall has a height of b and an axial pitch length (L) equal to channel height (H). Effects of flow blockage ratios, BR = b/H = 0.1-0.5, on heat transfer and pressure loss in the square channel are examined and also compared with the typical case of the transverse baffle (or 90° baffle). It is found that apart from the rise of Reynolds number, the increase in the blockage ratio with the attack angle (α) of 45° results in considerable increases in the Nusselt number and friction factor values. The use of the 45° baffle can help to generate a streamwise main vortex flow throughout the channel leading to fast and chaotic mixing of flow between the core and the wall regions. In addition, the computational results reveal that the significant increase in heat transfer rate is due to impingement jets induced by a longitudinal vortex pair (P-vortex) of flow, appearing on the upper, lower and baffle trailing end side walls. The appearance of vortex-induced impingement flows created by the baffles leads to the maximum thermal enhancement factor of about 2.2 at BR = 0.4 and Re = 1200. The enhancement factor of the 45° baffle investigated is found to be higher than that of the 90° baffle for all Reynolds numbers and baffle heights. © 2009 Elsevier Ltd. All rights reserved.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Numerical heat transfer study of square duct equipped with novel flapped V-baffles
    (2024-03-01) ; ;
    Skullong, Sompol
    ;
    Promthaisong, Pitak
    ;
    Nakhchi, Mahdi Erfanian
    The paper describes a computational study of heat transfer enhancement inside a square duct with V-shaped flapped baffles located repeatedly on the bottom and top walls for fluid flowing with Reynolds numbers (Re) from 3000 to 21,000. The basic goal of this work is to attain the largest relative Nusselt number (Nu/Nu<inf>0</inf>) whilst maintaining the highest thermal performance to improve energy savings. A finite volume method was used in the computations, along with the Realizable k‒ε turbulent model. The variable baffle parameters considered first in the current simulation were the relative height/blockade ratio (B<inf>R</inf> = 0.05−0.2) and the flap angle of the baffle hole (β = 0° − 90°), while the fixed parameters included the attack angle (α = 60°), hole diameter ratio (d<inf>R</inf> = 0.5), and pitch ratio (P<inf>R</inf> = 0.5). To accomplish this goal, the previously mentioned parameters providing the best thermal performance were investigated further by extending the values of B<inf>R</inf> to 0.25−0.3, d<inf>R</inf> to 0.8 and α to 45°−30°. The simulation results indicate that the jet flowing from the flapped hole, as well as the vortices created by the baffle, can boost heat transfer and friction loss in comparison to the plain duct. In comparison, using a flapped baffle with β > 0° results in less friction loss, a greater thermal enhancement factor (TEF), and a higher Nusselt number than using a baffle with no flap. The first investigation disclosed that for B<inf>R</inf> = 0.2 and β = 20°, the greatest TEF of 2.19 with Nu/Nu<inf>0</inf> of 7.9 times are obtained. The extended study, on the other hand, showed that the highest TEF of roughly 2.49 with Nu/Nu<inf>0</inf> of 8.4 times are seen for α = 45°, d<inf>R</inf> = 0.8, B<inf>R</inf> = 0.25 and β = 20° at lowest Re. Thus, the flapped baffle provides a significant increase in Nu/Nu<inf>0</inf> and TEF over the baffle alone.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Thermal characterization in a circular tube fitted with inclined horseshoe baffles
    (2015-01-22) ;
    Tamna, Sombat
    ;
    ;
    In the present study, the influence of inclined horseshoes baffles placed repeatedly in a tubular heat exchanger on heat transfer rate, friction factor and thermal enhancement factor are experimentally determined. The horseshoe baffle elements with an inclination angle of 20° were inserted periodically into the test tube at three different baffle-pitch ratios (P<inf>R</inf> = 0.5, 1.0 and 2) and -width or blockage ratios (B<inf>R</inf> = 0.1, 0.15 and 0.2). The experiment was conducted in the test tube having a uniform heat-fluxed wall by varying turbulent airflow to obtain Reynolds number in a range of 5300-24,000. The experimental results revealed that the tube fitted with inclined horseshoes baffles provides considerable improvement of the heat transfer rate over the plain tube around 92-208% while the friction factor is increased at about 1.76-6.37 times. To access the real benefits for the inclined horseshoes baffles inserted in plain tube, thermal performance factor is examined and found to be in the range of 1.34-1.92 at which the maximum obtained at P<inf>R</inf> = 0.5 and B<inf>R</inf> = 0.1 is considerably higher than that for published inserted devices. Correlations for Nusselt number and friction factor for the oblique horseshoe-baffled tube are also proposed.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Heat transfer behaviors in a solar air heater channel with multiple V-baffle vortex generators
    (2014-12-01)
    Tamna, Sombat
    ;
    Skullong, Sompol
    ;
    ;
    The article presents a study on heat transfer augmentation in a solar air heater channel fitted with multiple V-baffle vortex generators (BVG). During the test air was passed through the test channel under a uniform wall heat-flux of the absorber plate. The fluid flow and heat transfer characteristics are presented for Reynolds numbers based on the channel hydraulic diameter ranging from 4000 to 21,000. The V-baffles are applied at a relative baffle height (in terms of blockage ratio, BR. =. b/. H=. 0.25) and attack angle of 45° with respect to the main flow direction. The use of BVG in the channel is to generate multiple longitudinal vortex flows through the test channel to increase turbulence intensity and stronger mixing of fluid between the core and the near-wall flow. Influences of three different baffle-pitch to channel-height ratios (PR. =. P/. H=. 0.5, 1 and 2) on heat transfer and pressure drop in terms of respective Nusselt number and friction factor (or energy loss for propelling air through the channel) are examined. Three BVG arrangements, namely, one BVG wall (or single BVG), in-line and staggered BVGs on two opposite walls are also investigated. The experimental result reveals that the smaller PR provides the highest heat transfer and friction factor for all BVGs. The in-line BVG yields higher heat transfer and friction loss than the staggered and the single BVG. However, the single BVG with PR. =. 0.5 yields the highest thermal performance. To shed light of heat transfer mechanism, a numerical work is also conducted to investigate heat transfer and flow friction characteristics in the channel fitted with 45° BVGs and in comparison, the numerical results are in good agreement with experimental data.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Turbulent flow heat transfer and pressure loss in a double pipe heat exchanger with louvered strip inserts
    (2008-02-01)
    Eiamsa-ard, Smith
    ;
    Pethkool, Somsak
    ;
    ;
    In the present work, heat transfer and friction characteristics were experimentally investigated, employing louvered strips inserted in a concentric tube heat exchanger. The louvered strip was inserted into the tube to generate turbulent flow which helped to increase the heat transfer rate of the tube. The flow rate of the tube was in a range of Reynolds number between 6000 and 42,000. The turbulent flow devices were consisted of (1) the louvered strips with forward or backward arrangements, and (2) the louvered strip with various inclined angles (θ = 15°, 25° and 30°), inserted in the inner tube of the heat exchanger. In the experiment, hot water was flowed through the inner tube whereas cold water was flowed in the annulus. The experimental data obtained were compared with those from plain tubes of published data. Experimental results confirmed that the use of louvered strips leads to a higher heat transfer rate over the plain tube. The increases in average Nusselt number and friction loss for the inclined forward louvered strip were 284% and 413% while those for the backward louvered strip were 263% and 233% over the plain tube, respectively. In addition, the use of the louvered strip with backward arrangement leads to better overall enhancement ratio than that with forward arrangement around 9% to 24%. © 2007 Elsevier Ltd. All rights reserved.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Heat transfer evaluation of turbulent flows through gear-ring elements
    (2017-01-01)
    Ruengpayungsak, K.
    ;
    Wongcharee, K.
    ;
    ; ;
    Heat transfer and friction loss characteristics in tubular heat exchangers with gear-ring turbulators (GR-Ts) have been experimentally and numerically investigated. The GR-Ts with different free-space length ratios (SR = s/D = 1.0, 2.0 and 3.0) and tooth numbers (N = 8, 16 and 24), were experimentally tested under constant wall heat flux in turbulent flow (Reynolds numbers from 6000 to 20,000). Air was used as the working fluid. The behaviors in a plain tube and the tube with a conventional ring turbulators (N = 0) were also studied for comparison. The results show that utilizing tubes with GR-Ts leads to the increases of heat transfer coefficient and pressure loss as compared to those associated with the use of a plain tube. Heat transfer enhancement and friction increase with decreasing free-space length ratio (SR) and tooth number (N). Among the investigated inserts, the conventional ring turbulators (N = 0) with free-space length ratio, SR = 1.0 give the highest heat transfer rate and friction factor at 2.7 times and 15.5 times of those of the plain tube. However, the maximum thermal performance factor of 1.3 is obtained by using the GR-Ts with the largest free-space length ratio and maximum tooth number (SR = 3.0 and N = 24). At SR = 3.0, the GR-Ts with tooth numbers (N) of 0, 8, 16 and 24 yield thermal performance factors up to 1.24, 1.26, 1.28 and 1.3, respectively. The numerical results are given for a better understanding of flow and heat transfer characteristics associated with the use of GR-Ts.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Heat transfer performance evaluation of a solar air heater duct with multiple tapered V-baffles
    (2025-12-01) ;
    Kaewkosum, P.
    ;
    Woncharee, K.
    ;
    Keaitnukul, W.
    ;
    Maruyama, N.
    This report aims to study the heat transfer enhancement, pressure loss characteristics, and thermal performance of a channel equipped with multiple tapered V-shaped baffles (MTVBs). The effects of up-facing and down-facing orientations, converging (C) and diverging(D) configurations, variations in the taper ratio (e<inf>CR</inf> and e<inf>DR</inf> = 0.0 and 0.5), and Reynolds number (6000 ≤ Re ≤ 24,000) are examined. The performance of UF-C-MTVBs, DF-C-MTVBs, UF-D-MTVBs, and DF-D-MTVBs is analyzed and compared with that of the conventional transverse baffles (TBs) and MVBs (e<inf>DR</inf> = 1.0). The experimental setup maintained a constant attack angle (α) of 45°, pitch ratio (p/H) of 1.5, width-shaped ratio (W<inf>b</inf>/W) of 0.25, and blockage ratio (e/H) of 0.3. Tests were conducted at a fixed Prandtl number of 0.71, and a thermochromic liquid crystal sheet was utilized to assess the local Nusselt number distribution on the wall installed with UF-C-MTVBs, DF-C-MTVBs, UF-D-MTVBs, and DF-D-MTVBs. The results reveal that the channel with MVBs (e<inf>DR</inf> = 1.0) achieves the greatest heat transfer rate, with a Nu/Nu<inf>s</inf> ratio of up to 4.37 while a f/f<inf>s</inf> ratio reaching 48.12. In contrast, D-MTVBs at e<inf>DR</inf> = 0.0, despite having a lower Nu/Nu<inf>s</inf> ratio (maximum 3.87), attain the maximum thermal performance of 1.39 at Re = 6000, owing to their optimized design that effectively enhances heat transfer while minimizing pressure drop.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Turbulent heat transfer enhancement by counter/co-swirling flow in a tube fitted with twin twisted tapes
    (2010-01-01)
    Eiamsa-ard, S.
    ;
    ;
    Eiamsa-ard, P.
    In the present study, the influences of twin-counter/co-twisted tapes (counter/co-swirl tape) on heat transfer rate (Nu), friction factor (f) and thermal enhancement index (η) are experimentally determined. The twin counter twisted tapes (CTs) are used as counter-swirl flow generators while twin co-twisted tapes (CoTs) are used as co-swirl flow generators in a test section. The tests are conducted using the CTs and CoTs with four different twist ratios (y/w = 2.5, 3.0, 3.5 and 4.0) for Reynolds numbers range between 3700 and 21,000 under uniform heat flux conditions. The experiments using the single twisted tape (ST) are also performed under similar operation test conditions, for comparison. The experimental results demonstrate that Nusselt number (Nu), friction factor (f) and thermal enhancement index (η) increase with decreasing twist ratio (y/w). The results also show that the CTs are more efficient than the CoTs for heat transfer enhancement. In the range of the present work, heat transfer rates in the tube fitted with the CTs are around 12.5-44.5% and 17.8-50% higher than those with the CoTs and ST, respectively. The maximum thermal enhancement indices (η) obtained at the constant pumping power by the CTs with y/w = 2.5, 3.0, 3.5 and 4.0, are 1.39, 1.24, 1.12 and 1.03, respectively, while those obtained by using the CoTs with the same range of y/w are 1.1, 1.03, 0.97 and 0.92, respectively. In addition, the empirical correlations of the heat transfer (Nu), friction factor (f) and thermal enhancement index (η) are also reported. © 2009 Elsevier Inc. All rights reserved.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Performance of a heat exchanger with compound inclined circular-rings and twisted tapes
    (2022-09-01) ;
    Samruaisin, P.
    ;
    ;
    Ruengpayungsak, K.
    ;
    Eiamsa-Ard, P.
    Optimization was done of the aerothermal performance factor (η) of a tube into which a combination of inclined circular-rings (ICRs) and twisted-tapes (TTs) were installed. The key contribution of this research is determination of the appropriate ICR and TT sizes to produce the best heat exchanger performance. An ICR's purpose is to produce counter-rotating vortices, whereas the TT's role is to create swirl flow within a tube to improve turbulence and transfer cold fluid from the core region to the heated-wall zone. The influence of circular-ring inclination angle (α = 30o, 45o, 60o and 90o), number of twisted tapes (H = 2, 4, and 6) and twist ratios (TR = 1.0, 2.0, and 3.0) on heat transfer and pressure losses were assessed to determine an optimum η condition. The heat transfer and friction factor tend to increase with H values and decreasing TR. The heat transfer of ICRs together with TTs is higher than in a plain tube by up to 128.7% and 155.3%, respectively, while it is better than the transverse circular-ring (α = 90o) and twisted-tape by up to 116.9% and 146.5%, respectively. Furthermore, due to moderate heat transfer and low pressure losses, a maximal η of 1.66 was achieved for α = 30o, H = 2 and TR = 3.0 within the examined range.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Influence of sawtooth twisted tape on thermal enhancement of heat exchanger tube
    (2023-03-01)
    Samutpraphut, Boonsong
    ;
    Eiamsa-ard, Smith
    ;
    ; ;
    Maruyama, Naoki
    This article employs sawtooth twisted tapes to generate swirling flow and interrupted flowing disturbance in order to increase the level of heat transfer rate. The influences of the sawtooth twisted tape (S-TT) on enhanced heat transfer rate, friction factor and aerothermal performance index (API) behaviors are analyzed. The sawtooth twisted tapes (S-TTs) possessing constant pitch/twist ratio (y//W) of 3.0 and six sawtooth angles (α) of 20°, 30°, 40°, 50°, 60°, and 70° are assessed. Considering turbulent flow using air as the testing fluid, experiments were investigated at 6,000 < Re < 20,000 under boundary conditions of constant heat flux. According to the experimental findings, sawtooth twisted tape (S-TT) improves heat transfer rate and raises pressure loss with varying rates based on sawtooth angles (α). With the sawtooth twisted tape (S-TT) and 70° sawtooth angles, the optimum API of 1.33 is attained, while Nusselt number and friction factor are 32 and 0.135 at Re = 6,000. The recommended sawtooth twisted tape (S-TT) yields a highest Nusselt number of 78, which is 1.6 times greater than the typical twisted tape (TT) and 1.1 times greater than the plain tube. The combination of the TT and sawtooth patterns can be beneficial in terms of boosting heat transfer rate and API relating coupling of swirling flow and interrupted flowing disruption effects since the sawtooth twisted tape (S-TT) offers superior performance than the TT. Additionally, the heat exchanger tubes fitted with sawtooth twisted tape (S-TT) at sawtooth angles (α) of 20°, 30°, 40°, 50°, 60°, and 70° gain greater Nusselt number than the plain tube up to 158.3%, 162.2%, 166.1%, 171.7%, 179.7% and 186.2%, respectively.