Klongratog, Bhanupol
Loading...
Preferred name
Klongratog, Bhanupol
Alternative Name
Klongratog, B.
Klongratog, Bhanupo
Main Affiliation
Email
bhanupol.kl@kmitl.ac.th
5 results
Now showing 1 - 5 of 5
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Capacitive measuring of crude palm oil-water mixture(2017-12-13) ;Sriphant, Pongsakun ;Srongprapa, AnupongOil palm is one of the famous commercial crops of Thailand. The production is in the 3<sup>th</sup> rank of the south east Asia, and plantation is still increasing every year. To investigate the feasibility of using electrical capacitance measuring technique as an alternative method for low-cost non-destructive, oil palm fresh oil (CPO) and water have been prepared and studied. One group is concerned with the immiscible fluid and another is all ultrasonic shakes. The mass concentration (x) of CPO varied from 0 g/cm<sup>3</sup> to 0.9 g/cm<sup>3</sup> and then all experiments were tested on room temperature (25<sup>o</sup>C). Guard parallel structure has been used in conjunction with AD7747 capacitive to digital converter to obtain capacitance value (y). The results show that y = 0.11987x<sup>2</sup> - 0.46104x + 0.47418 with r<sup>2</sup> = 0.98098. The model for second sample is y = 0.08965x<sup>2</sup> - 0.41335x + 0.3731 with r<sup>2</sup> = 0.9554. The capacitance of first sample is higher than the second sample. As previously mentioned, this project aims to make benefit of interest on seasonable optimistic harvests. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, The uncertainty in sugar solution concentration measurement based on density approach(2013-11-04); ; The concentration of solution used in osmotic process is an important factor to dehydrate water from food, which is an effect to the rate of mass transfer. Therefore, the in line measurement and control of the concentration in osmotic process is taken into account. The density of sugar solution can be computed by volume and weight in order to determine the concentration in degree of Brix. This instrument will complete when accompanied by a statement of its uncertainty. The calibration equation established the relationship between the reading values of sensor and the values of concentration also need to clarify. The objective of this paper is to evaluate the uncertainty of predicted values of calibration equation; therefore, the uncertainty is determined in this study, and to compare the obtained results from the classical method in linear equation and the inverse method. Furthermore, the data from Monte Carlo simulations also are compared to the measured data. © (2013) Trans Tech Publications, Switzerland. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Estimation of Vertical Jump Height using Capacitive Sensing Method(2023-01-01); ; ;Inboonma, Weerayut ;Sukprasertchai, SiwakornThis paper presents a low-cost vertical jump height measuring device based on the time-of-flight technique. A capacitive mat was developed and used as a sensing element to sense the athlete's feet. The capacitive mat was made from aluminum foils that dimensions of the capacitive mat ware with a width of 50.3 cm x length of 70.6 cm. The signal conditioning circuitry that was used as an analog front-end for measuring the capacitive was also described. The time difference between when athletes jumped off and reached the ground was calculated by a microcontroller. The jump height was recorded and stored via the computer. A total of 27 athletes, weighted between 48 kg to 115 kg were used as a sample. The testing results have shown that the proposed system has a percentage difference of 18.16%. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Estimation of vertical jump height using nintendo Wii remote IR camera(2018-12-05); ;Pengto, Warit ;Wornkert, TodsapornSrongprapa, AnupongIn this article, we proposed to measure the heights of countermovement jumps which are recorded in term of vertical leap by using the Wii Remote infrared camera. According to the physical principles, positions of the movement were detected based on the rules regarding conservation of energy, motion under gravity, and coordinate system. The obtained results were compared with that of the slow-motion measurements. The experiment involved 30 basketball players whose jump results were slightly deviated from the vertical measurement of the coordinate system. Therefore, the results should be calibrated each time the new system is installed. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Saline solution concentration measurement based on contact angle approach(2017-12-13); ;Srongprapa, Anupong ;Mannaramit, PadetLeelaphaiboon, MongkolThere are a number of factors that affect the quality control of an osmotic product. One of these is the concentration of the osmotic solution. There are several ways to measure solution concentration, such as optical measurement method, freezing point temperature measurement method, wave principle measurement method, viscosity and specific gravity measurement method. Saline solution concentration of the osmotic solution based on contact angle. The experiments showed whenever the saline solution concentration increased, the contact angle measured on the acrylic substrate increased as well. Their relation is also the linear correlation. Lastly, the developed software evaluated the saline solution concentration based on the contact angle close to the prepared saline solution concentration. The measured concentration was linear correlation with R-squared value of 0.996 that can be accurately applied on concentrations of 5% to 30% with maximum error of 4.72%.
