Item type:Publication, A phase diagram approach to the detection and location of faulty capacitor units in A 115-kV capacitor bank based on unbalanced current arguments(2023-03-01); ;Lertwanitrot, PraikanokThe protection of traditional high voltage capacitor banks relies on an unbalance relay which operates when an internal fuse is blown. However, the unbalance relay cannot indicate cause or position of the fault. Thus, an operator wastes time and human resources investigating the fault issues. To address this issue, a method to locate the fault position in a capacitor bank is developed in this study. The study was simulated by using PSCAD software and modeled on the 115-kV system of the Electricity Generating Authority of Thailand (EGAT). Case studies involving faults with varied phases, side and branch connections, row connections, and inception angles were considered. Moreover, the magnitude and argument of the current phase and unbalanced current were analyzed to identify the fault location in a capacitor bank. The performance of the proposed method was verified via comparison with that of traditional methods and the results of laboratory experiments. In addition, various voltage systems were observed to verify the flexibility and accuracy of the proposed method. The results demonstrate that the proposed method was more efficient than traditional methods at locating the fault position in a capacitor bank. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Identification of the fault location for three-terminal transmission lines using discrete wavelet transforms(2009-12-16) ;Chiradeja, P.This paper proposes a technique to detect fault locations in a three-bus transmission system using discrete wavelet transform (DWT). The comparison among the first peak time in first scale of each terminal (buses) that can detect fault is performed and the two fastest first peak time obtained from comparison are used as an input data for traveling wave equation later. A comparison of results obtained from three different types of mother wavelet is discussed in order to identify the fault locations with an application of traveling wave theory. It is shown that the db4 mother wavelet produces better results than those from 'sym4' and 'coif4', with a mean error of less than 400 m. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Identification of fault location for simultaneous fault in distribution system using discrete wavelet transform(2011-04-01); ; ; Apisit, C.Currently, the most effective technique for identifying fault location, based on a travelling wave, has been proposed in several research papers. However, the effects of simultaneous faults have been neglected. In order to overcome this problem, a new algorithm will be developed in order to predict fault location precisely. This paper presents a technique to detect fault locations, during simultaneous fault, in an underground distribution system using discrete wavelet transform (DWT). The DWT is used to detect the high frequency components. The time that the fault signal uses to reach the ends of the distribution line is considered, then, applied so that the distance of fault can be calculated. The result is found that the proposed algorithm gives satisfactory both in case of single fault and simultaneous fault. ICIC International © 2011. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Identification of fault locations in underground distribution system using Discrete Wavelet Transform(2010-12-01); ;Apisit, C.; ; Jaikhan, S.In this paper, a technique for detecting faults in underground distribution system is presented. Discrete Wavelet Transform (DWT) based on traveling wave is employed in order to detect the high frequency components and to identify fault locations in the underground distribution system. The first peak time obtained from the faulty bus is employed for calculating the distance of fault from sending end. The validity of the proposed technique is tested with various fault inception angles, fault locations and faulty phases. The result is found that the proposed technique provides satisfactory result and will be very useful in the development of power systems protection scheme.