Ngamroo, Issarachai
Loading...
Preferred name
Ngamroo, Issarachai
Alternative Name
Ngamroo, I.
Main Affiliation
Email
issarachai.ng@kmitl.ac.th
108 results
Now showing 1 - 10 of 108
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Improvement of power system transient stability by PV farm with fuzzy gain scheduling of PID controller(2017-09-01) ;Chaiyatham, TheerawutThe extensive proliferation of large photovoltaic (PV) farms in power systems deteriorates both system inertia and synchronizing coupling. Under the occurrence of severe faults, the power system transient stability may be jeopardized. Nevertheless, the fast active power control ability of the PV inverter leads to the possibility of transient stability improvement. This paper focuses on the new application of large PV farms equipped with a fuzzy gain scheduling of proportional-integral-derivative (FGS-PID) controller for transient stabilization of a multimachine power system. The FGS-PID controller is used to control the PV inverter, so that the PV power output can be modulated to stabilize the transient power swing when the faults take place. To obtain the stabilizing performance, the scale factors, membership functions, and control rules of the FGS-PID controller are determined by a bee colony optimization. Simulation study in a two-area interconnected power system exhibits the superior stabilizing effect and robustness of the PV with FGS-PID controller over the PV with maximum power point tracking (MPPT) controller, optimal PID controller, and Ziegler-Nichols tuned PID controller, under various faults, line flows, and solar insolations. In addition, without losing the main function of power generation, the PV with FGS-PID control is able to supply energy to the system almost equal as the PV with MPPT, during stabilization. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Robust power oscillation damper design for DFIG-based wind turbine(2013-09-02); ; Nakawiro, WorawatA new robust power oscillation damper (POD) design for a doubly fed induction generator based- wind turbine is proposed in this paper. The POD structure is specified by the second-order lead/lag compensator with single input signal. The parameters optimization of POD is formulated based on a mixed H<inf>2</inf>/H<inf>∞</inf> control using linear matrix inequalities. The POD parameters are optimized by the firefly algorithm so that the damping performance against system disturbances and the robustness under system uncertainties are satisfied. Simulation results in a single machine infinite bus confirm the superior robustness of the proposed POD over the conventional POD. © 2013 IEEE. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, An open circuit fault diagnostic technique in IGBTS for ac to dc converters applied in microgrid applications(2011-01-01); ;Sae-Kok, WarachartAn open circuit fault diagnostic method in IGBTs for the ac to dc converters used in microgrid applications is developed in this paper. An ac to dc converter is a key technology for microgrids in order to interface both distributed generation (DG) and renewable energy resources (RES). Also, highly reliable ac to dc converters are necessary to keep converters in continuous operation as long as possible during power switch fault conditions. Therefore, the proposed fault diagnostic method is developed to reduce the fault detection time and to avoid any other fault alarms because continuous operation is desired. The proposed diagnostic method is a combination of the absolute normalized dc current technique and the false alarm suppression algorithm to overcome the long fault detection time and fault alarm problems. The simulation and experimental results show that the developed fault diagnostic method can perform fault detection within about one cycle. The results illustrate that the reliability of an ac to dc converter interfaced with a microgrid can be improved by using the proposed fault diagnostic method. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Application of electrolyzer to alleviate power fluctuation in a stand alone microgrid based on an optimal fuzzy PID control(2012-12-01)Due to the high intermittent power generations from wind and photovoltaic in the microgrid (MG) system, these result in the severe power fluctuation. When the fuel cell (FC) equipped with the aqua electrolyzer (AE) has been installed in the MG, in addition to hydrogen production for FC, the absorbed power by AE can be controlled to alleviate the power fluctuation. This paper proposes the coordinated control of AE and FC to solve the power fluctuation problem in the MG. By control of the power absorption by AE and the power production by FC, the power fluctuation in the MG can be suppressed. The optimal fuzzy logic based-proportional-integral-derivative (FLPID) is used to design the controllers of AE and FC. Without trial and error as in the conventional FLPID controller design, scale factors, membership functions and control rules of the optimal FLPID controller are automatically and simultaneously tuned by a bee colony optimization. Simulation results confirm the superior stabilizing effect of the proposed optimal FLPID controller in comparison with the conventional FLPID controller under several system disturbances. © 2012 Elsevier Ltd. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Transient stabilization of power swing by controllable PV farm equipped with optimal fuzzy gain scheduling of PID controller(2014-10-15) ;Chaiyatham, TheerawutThe severe faults in power systems may cause the power swing and transient instability. On the other hand, recently, the large photovoltaic (PV) farms have been extensively installed in power systems. With the ability of PV inverter, it is possible to control the PV output power quickly to stabilize the power swing. This paper proposes an optimal fuzzy gain scheduling of PID (FGS-PID) controller equipped with the PV inverter for stabilization of power swing. Without trial and error, the scale factors, membership functions and control rules of the FGS-PID controller are automatically obtained by a bee colony optimization. Simulation study in a single machine infinite bus system confirms the superior stabilizing effect of the PV with proposed FGS-PID in comparison to the PV with MPPT and the PV with PID. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Coordinated PHEV, PV, and ESS for Microgrid Frequency Regulation Using Centralized Model Predictive Control Considering Variation of PHEV Number(2018-01-01) ;Pahasa, J.The integration of plug-in hybrid electric vehicles (PHEVs), photovoltaic (PV) generators, and energy storage systems (ESSs) into microgrids is highly anticipated. A coordinated control of PHEVs, PVs, and ESS will support frequency control in a microgrid. However, the size of the ESS depends on the surplus power of PV. The lower the surplus power is, the smaller the size of ESS. Furthermore, the number of available PHEVs vary with the cumulative number of the participating PHEVs. This variation of the number of PHEVs may reduce the PHEVs' control effect in the microgrid. This paper proposes a coordinated control of PHEVs, PVs, and ESSs for frequency control in the microgrid using a centralized model predictive control (CMPC) considering the variation of PHEV numbers. The objectives of the coordinated control are: 1) to suppress the system frequency fluctuation and 2) to minimize the surplus power of PV and, therefore, reduce the size of ESS. Simulation studies indicate that the coordinated control of PHEVs, PVs, and ESSs by the proposed CMPC is superior to that of the proportional integral derivative control and the distributed MPC in terms of minimizing the frequency fluctuation, the PV surplus power, and the ESS size. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Wide-area robust SMES controller design using synchronized PMUS for stabilization of interconnected power system with wind farms(2010-01-01); ;Nanda, Cuk Supriyadi Ali ;Dechanupaprittha, Sanchai ;Watanabe, MasayukiMitani, YasunoriThe high penetration of wind power into interconnected power system may cause the severe problem of inter-area oscillations. To stabilize power oscillations, superconducting magnetic energy storage (SMES), which is capable of controlling active and reactive powers simultaneously, can be applied. To achieve the practical SMES controller design, this paper focuses on a robust SMES controller design based on wide-area synchronized phasor measurement units (PMUs) in an interconnected power system with wind farms. The structure of active and reactive power controllers of SMES is the first-order lead/lag compensator. Assuming that multiple PMUs are located in an interconnected power system, the steady-state phasor data are obtained by applying the small load perturbation. Using the phasor data, the simplified oscillation model (SOM) included with SMES power controllers can be identified and applied to estimate the dominant inter-area oscillation modes. In the design, unstructured system uncertainties such as various operating conditions, system parameters variation, random wind patterns, etc., are represented by the inverse additive perturbation. To enhance the system robust stability margin, the optimization of SMES control parameters is solved by genetic algorithm in the SOM. Simulation studies in the West Japan six-machine power system confirm that the robustness of the proposed SMES is much superior to that of the conventional SMES against various operating conditions. © 2010 Institute of Electrical Engineers of Japan. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Optimal Superconducting Coil Integrated into PV Generators for Smoothing Power and Regulating Voltage in Distribution System with PHEVs(2016-10-01) ;Kreeumporn, WorapongNowadays, the proliferation of photovoltaic (PV) generators and plug-in hybrid electric vehicles (PHEVs) into power distribution systems highly escalates. The variable PV power and the abrupt power charging of PHEVs result in system power and voltage fluctuations. This paper presents the new application of the superconducting coil (SC), which is connected between the dc link of PV generators to solve this problem. Using the dc-to-dc converter as an interfaced circuit, the SC can share the inverters with the PV generators. In addition, the PV generators with the common SC are able to provide the smooth power output and regulate the system voltage. The PV inverters and the dc-to-dc converter are controlled by the proportional-integral (PI) controllers. The optimization of the PI parameters and SC inductance is performed, so that the power and voltage fluctuations are minimized. Simulation results indicate that the PV generators with the common SC, which has a lower SC inductance, provide the same smoothing effect on the PV power fluctuation as the superconducting magnetic energy storage (SMES) installed at the PV terminal. In addition, they give the superior voltage regulation effect to the SMES. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, WLAV state estimation for power system containing multitype FACTS devices(2013-01-01) ;Rakpenthai, Chawasak ;Uatrongjit, SermsakThis paper presents the state estimation of power system in which not only the bus voltages but also the states of the flexible AC transmission system (FACTS) are considered as the state variables. By using the rectangular form of state variables and equivalent measurement techniques, a linear measurement model with constraints of FACTS device is obtained. The predictor-corrector interior point method based on the weighted least absolute value criterion is developed for solving the optimization problem. Simulation results on the modified IEEE 14-bus and 118-bus test systems are provided. The numerical results indicate the effectiveness of the proposed approach. © 2013 Institute of Electrical Engineers of Japan. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Wide area robust centralized power oscillation dampers design for DFIG-based wind turbines(2014-02-10); Inter-area oscillations are associated with machines in one part of the system oscillating against machines in other parts of the system. They are caused by two or more groups of machines that are interconnected by weak ties. To damp out the inter-area oscillations, this paper proposes the new application of wide area stability control for robust centralized power oscillation dampers (PODs) design of doubly-fed induction generator (DFIG) wind turbines. The POD with 2<sup>nd</sup>-order lead/lag compensator structure for each DFIG wind turbine is located at the control center. To stabilize the target inter-area mode effectively, the geometric measures of controllability and observability are used to choose the suitable DFIG wind turbine for stabilizing the target oscillation mode, the proper input signal of POD, and the location of phasor measurement units (PMUs). The input signal of each POD is obtained from PMU while the output signal is transmitted to the rotor side converter voltage controller of DFIG. As a result, the reactive power output of DFIG can be modulated to damp out inter-area oscillations. In the POD parameters optimization, the wide range of power output levels of DFIGs and synchronous generators, time delays due to wide area communication, and unstructured system uncertainties model are taken into account so that the damping of inter-area modes and the system robust stability margin against uncertainties can be guaranteed. Solving the problem by the firefly algorithm automatically, the optimal parameters of PODs can be achieved. The stabilizing performance and robustness of the proposed robust centralized POD are evaluated in the IEEE New England 39 bus system by eigenvalue analyses and nonlinear simulation in scenarios with severe short circuits, N-1 outage contingencies, heavy power flows, and line tripping.