    Experimental Study of the Effects of Inclusion of Rectangular-Cut Twisted Tapes on Heat Transfer and Pressure Drop in a Round Tube
    (2019-12-01)
    Ruengpayungsak, K.
    ;
    Kumar, Manoj
    ;
    ;
    Eiamsa-ard, S.
    Twisted tape inserts were used as swirl generators in the flow through a tube for enhancing heat transfer. Twisted tapes have commonly been applied in many thermal applications used in industry. Several modified twisted tapes have been investigated for improving the thermal performance of heat exchangers. The effects in tubes with modified rectangular-cut twisted tape (RC-TT) inserts with various free-spacing ratios (s/w = 2.0, 2.5, 3.0, 3.5 and 4.0) and edge–width ratios (t/W = 0.1, 0.15, 0.2 and 0.25) on heat transfer and pressure losses are reported. The RC-TT used in this work had a fixed thickness of 1.2 mm, width of 60 mm, length of 2000 mm and twist ratio (y/W) of 3.0. Experiments were performed over a range of Reynolds numbers, 10,000 ≤ Re ≤ 20,000, using air as a test fluid. A tube with a classical/typical twisted tape was also tested for comparison. In all cases, the Nusselt number tended to increase with the Reynolds number, while the friction factor and thermal performance showed the opposite trend. For the rectangular-cut twisted tape inserts, the friction factor and Nusselt number decreased, while thermal performance increased with increasing free-spacing ratios (s/w) and edge–width ratios (t/W). Furthermore, the maximum thermal performance was achieved at the lowest free-spacing ratio (s/w), edge–width ratio (t/W) and Reynolds number (Re).
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Experimental investigation and ANN prediction of heat transfer enhancement in a heat exchanger tube utilizing twin corrugated twisted tapes
    (2025-12-01)
    Du, Y.
    ;
    Wongcharee, K.
    ;
    ; ;
    Chamoli, S.
    This report introduces a novel twin-corrugated twisted tape (TC-TT) insert designed to enhance heat transfer in exchanger tubes. The key innovation lies in the twin-corrugated structure, which generates a twin-swirl flow effect. The corrugated surface synergistically increases flow disturbance and expands the effective heat transfer area. The studied parameters were twist ratios (y/w = 3.0, 3.5, and 4.0) and corrugation angles (θ = 45°, 60°, 75°, and 90°) at 6,000 ≤ Re ≤ 20,000. The results show that using twin-corrugated twisted tapes increases the average Nusselt number by roughly 60–135% compared to a plain tube and by 16–35% compared to a conventional single-twisted tape, confirming the effectiveness of this structural modification. This enhancement is primarily due to the combination of double swirling-flows and enhanced effective heat transfer generated by the corrugated surface. Reducing the corrugation angle (θ) and twist ratio (y/w) led to increases in the Nusselt number (Nu), friction factor (f), and thermal performance factor (TPF). Within the studied range, the Nusselt number, friction factor, and thermal performance factor reached maximum values of 5.18, 0.153, and 1.44, respectively, at a twist ratio of 3.0, a corrugation angle of 45°, and Re = 6,000. Regression analysis was utilized to develop correlations for the Nu and f, considering the Re, Pr, y/w, and θ as influencing variables. The proposed correlations for predicting the friction factor and Nusselt number have errors within ±3% and ±2%, respectively. In addition, an artificial neural network (ANN) was developed for predicting the thermal performance values occurring below the experimental study range. The optimal state ANN model shows remarkable prediction accuracy with R<sup>2</sup> of 0.965.