Chuwattanakul, Varesa
Loading...
Preferred name
Chuwattanakul, Varesa
Alternative Name
Chuwattanakul, V.
Main Affiliation
Email
varesa.ch@kmitl.ac.th
2 results
Now showing 1 - 2 of 2
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Effects of spiral start number and depth ratio of corrugated tube on flow and heat transfer characteristics in turbulent flow region(2019-08-01) ;Kongkaitpaiboon, V. ;Promthaisong, P.; ;Wongcharee, K.Eiamsa-ard, S.Influence of spirally-corrugated tubes on heat transfer (Nu), pressure loss (f) and thermal enhancement factor (TEF) characteristics was numerically investigated. The physical models of spirally-corrugated tubes and also a straight circular tube were built for the comparative study. The predictions were performed for the spirally-corrugated tubes with spiral start numbers (N) of 2, 3, 4 and 5 and depth ratios (DR = e/D) of 0.02, 0.04, 0.06, 0.08, 0.1, 0.12, 0.14 and 0.16 at Reynolds numbers of 5000, 8000, 14000 and 20000. The numerical results show that the spiral corrugated tubes created two types of flow structures: main swirl flows (appear around the core) and secondary swirl flows (appear near tube wall) which facilitate heat transfer between the fluid and the tube walls. The overall heat transfer depends on the competition between two effects: the positive effect of the stronger swirl intensity by increasing start number and the negative effect of the difficulty of fluid transfer into grooves by increasing depth ratio. For the investigated range, the corrugated tubes yield Nusselt numbers and thermal performance factors varying from 0.82 to 2.16 times and 0.66–1.2 times of the straight circular tube, respectively. The highest thermal enhancement factor (TEF) of 1.2 is achieved by using the tube with spiral start number of 4 having moderate depth ratio of 0.08 at Re = 5000. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Influence of three-start spirally twisted tube combined with triple-channel twisted tape insert on heat transfer enhancement(2016-04-01) ;Eiamsa-ard, S. ;Promthaisong, P.; ; In the present article, heat transfer enhancement by three-start spirally twisted tube combination with triple-channel twisted tape is studied numerically using RNG k-ε turbulence model. Influences of the tape width ratio (w/D = 0.1, 0.25, 0.34 and 0.5) and tube/tape arrangement (belly-to-belly and belly-to-neck arrangements) are described. The numerical results of a twisted tube without tape and a circular plain tube are also given for comparison. The results are reported in terms of velocity field, temperature field, turbulent kinetic energy, local Nusselt number distribution, average Nusselt number, pressure loss and thermal performance factor. It is found that heat transfer and friction factor increase with tape width ratio. At a given tape width, the systems in belly-to-neck arrangement are more efficient for heat transfer enhancement than the ones in belly-to-belly arrangement. The three-start spirally twisted tubes with twisted tapes in belly-to-neck arrangement at w/D = 0.1, 0.25 and 0.34 give higher Nusselt numbers than the twisted tube without tape up to 1.2%, 21% and 36%, respectively. The twisted tubes with triple-channel twisted tape in belly-to-belly arrangement provide higher Nusselt numbers than the twisted tube without tape up to 1.23%, 6.7%, 10% and 17%, respectively. The superior heat transfer of the combined devices in belly-to-neck arrangement (especially at large w/D) is attributed to the stronger interaction between the swirling flows induced by the tubes and those induced by the tapes. Moreover, the systems in belly-to-neck arrangement cause lower friction loss than the ones in belly-to-belly arrangement. Thus, the systems in belly-to-neck arrangement yield higher thermal performance factors. Among the studied cases, the twisted tube combined with triple-channel twisted tape in belly-to-neck arrangement at w/D = 0.34 possesses the maximum thermal performance of 1.32 at Reynolds number of 5000.
