    Experimental investigation and ANN prediction of heat transfer enhancement in a heat exchanger tube utilizing twin corrugated twisted tapes
    (2025-12-01)
    Du, Y.
    ;
    Wongcharee, K.
    ;
    ; ;
    Chamoli, S.
    This report introduces a novel twin-corrugated twisted tape (TC-TT) insert designed to enhance heat transfer in exchanger tubes. The key innovation lies in the twin-corrugated structure, which generates a twin-swirl flow effect. The corrugated surface synergistically increases flow disturbance and expands the effective heat transfer area. The studied parameters were twist ratios (y/w = 3.0, 3.5, and 4.0) and corrugation angles (θ = 45°, 60°, 75°, and 90°) at 6,000 ≤ Re ≤ 20,000. The results show that using twin-corrugated twisted tapes increases the average Nusselt number by roughly 60–135% compared to a plain tube and by 16–35% compared to a conventional single-twisted tape, confirming the effectiveness of this structural modification. This enhancement is primarily due to the combination of double swirling-flows and enhanced effective heat transfer generated by the corrugated surface. Reducing the corrugation angle (θ) and twist ratio (y/w) led to increases in the Nusselt number (Nu), friction factor (f), and thermal performance factor (TPF). Within the studied range, the Nusselt number, friction factor, and thermal performance factor reached maximum values of 5.18, 0.153, and 1.44, respectively, at a twist ratio of 3.0, a corrugation angle of 45°, and Re = 6,000. Regression analysis was utilized to develop correlations for the Nu and f, considering the Re, Pr, y/w, and θ as influencing variables. The proposed correlations for predicting the friction factor and Nusselt number have errors within ±3% and ±2%, respectively. In addition, an artificial neural network (ANN) was developed for predicting the thermal performance values occurring below the experimental study range. The optimal state ANN model shows remarkable prediction accuracy with R<sup>2</sup> of 0.965.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Thermal performance of heat exchanger tube installed with triple twisted-tapes
    (2020-09-01)
    Samutpraphut, B.
    ;
    Promthaisong, P.
    ;
    Wongcharee, K.
    ;
    Eiamsa-Ard, S.
    ;
    A current study deals with the numerical analysis of heat transfer intensification, flow-thermal fields, local heat transfer distribution, friction factor and thermal performance behavior of the heat exchanger tubes installed with triple twisted tapes. Each set of triple twisted tapes consists of three twisted tapes having an identical twist ratio. Twisted tapes of interest have three different twisted ratios (y/w = 1.0, 1.5 and 2.0). Simulation was performed for the turbulent flow with Reynolds numbers (Re) ranging from 5000 to 20,000. Numerical results indicate that the use of triple twisted-tapes leads to heat transfer enhancement. Nusselt number (Nu) and friction factor (f) increase while thermal performance factor () decreases with decreasing twist ratio of triple twisted tapes. The Nusselt numbers of the tubes installed with triple twisted-tapes having twist ratios of 1.0, 1.5 and 2.0 are higher than those of the plain tube by around 3.34-4.45, 2.75-3.65 and 2.56-3.41 times, respectively. Friction factors (f) of the tubes installed triple twisted-tapes with twist ratios of 1.0, 1.5 and 2.0 are increased up to 46.1-49.7, 24.16-26.04 and 15.86-17.09 times, respectively, as compared to those of the plain tube. The maximum thermal performance factors of 1.21, 1.23 and 1.32 are obtained by using triple twisted tapes with y/w = 1.0, 1.5 and 2.0 at the Reynolds number of 5000.