Chuwattanakul, Varesa
Loading...
Preferred name
Chuwattanakul, Varesa
Alternative Name
Chuwattanakul, V.
Main Affiliation
Email
varesa.ch@kmitl.ac.th
5 results
Now showing 1 - 5 of 5
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Experimental Study of the Effects of Inclusion of Rectangular-Cut Twisted Tapes on Heat Transfer and Pressure Drop in a Round Tube(2019-12-01) ;Ruengpayungsak, K. ;Kumar, Manoj; Eiamsa-ard, S.Twisted tape inserts were used as swirl generators in the flow through a tube for enhancing heat transfer. Twisted tapes have commonly been applied in many thermal applications used in industry. Several modified twisted tapes have been investigated for improving the thermal performance of heat exchangers. The effects in tubes with modified rectangular-cut twisted tape (RC-TT) inserts with various free-spacing ratios (s/w = 2.0, 2.5, 3.0, 3.5 and 4.0) and edge–width ratios (t/W = 0.1, 0.15, 0.2 and 0.25) on heat transfer and pressure losses are reported. The RC-TT used in this work had a fixed thickness of 1.2 mm, width of 60 mm, length of 2000 mm and twist ratio (y/W) of 3.0. Experiments were performed over a range of Reynolds numbers, 10,000 ≤ Re ≤ 20,000, using air as a test fluid. A tube with a classical/typical twisted tape was also tested for comparison. In all cases, the Nusselt number tended to increase with the Reynolds number, while the friction factor and thermal performance showed the opposite trend. For the rectangular-cut twisted tape inserts, the friction factor and Nusselt number decreased, while thermal performance increased with increasing free-spacing ratios (s/w) and edge–width ratios (t/W). Furthermore, the maximum thermal performance was achieved at the lowest free-spacing ratio (s/w), edge–width ratio (t/W) and Reynolds number (Re). - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Turbulent heat transfer enhancement in round tubes by inserting triple twisted-tapes(2015-01-01) ;Eiamsaard, S. ;Promthaisong, P.Turbulent flow characteristics and heat transfer performances in a round tube equipped with triple twisted tapes are investigated numerically. Effects of the triple twisted tapes at different twist ratios on the heat transfer and thermal performance characteristics are reported. The results of velocity and temperature fields, and the local heat transfer coefficients as well as the flow structure in tube with tape inserts are also given. A round tube wall is subjected to a constant wall temperature condition. Thermal field, heat transfer and fluid flow characteristics are studied using computational fluid dynamics (CFD) analysis. Computations, based on a finite volume method, are carried out by utilizing the Renormalized Group (RNG) k-e turbulence model. The investigation is carried out for triple twisted tapes with y/W = 2.0, 3.0 and 4.0 in round tubes for laminar air flow with Reynolds numbers between 500 and 2000. It is found that the use of triple twisted tapes with smallest twist ratio of y/W =2.0 results in the highest heat transfer and friction factor while the use of the tapes with the largest twist ratio (y/W = 4.0) results in the highest thermal performance. The highest thermal performances based on the constant pumping power criterion of the tubes equipped triple twisted tapes with y/W = 2.0, 3.0 and 4.0 are 2.43, 2.63 and 2.73, respectively. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Evaluation of heat transfer performance of a heat exchanger tube mounted with an I-rib twisted tape and twisted winglets(2025-12-01) ;Qiu, Wenxuan ;Samruaisin, Prachya; ;Maruyama, NaokiHirota, MasafumiThis study aims to improve the efficiency of heat exchangers and explore the enhancement mechanism of the thermal performance characteristics of heat exchange tubes by I-rib twisted tapes and twisted winglets (I-RTTW) through experimental research and numerical simulation. The I-RTTW structure consists of a central I-type rib and an edge twisted winglet. The key geometric parameters of the edge twisted winglet include the wing depth ratio (d/W = 0.096, 0.13, 0.16), the wing width ratio (w/W = 0.096, 0.13, 0.16), and a fixed twist angle of 45°. The study uses air as the working fluid to systematically analyze the heat transfer performance of the I-RTTW over a range of Reynolds numbers (Re) of 6,000–20,000. The experimental results reveal that the I-RTTW significantly improves heat transfer through a dual mechanism. First, the edge twisted winglet effectively disrupts the fluid boundary layer by inducing secondary flows. Second, the central I-type rib can promote radial mixing of the fluid. Further in-depth analysis of the experimental data revealed that a greater winglet depth ratio (d/W) increases the longitudinal size of the cutting winglet, thereby disturbing the fluid more deeply and increasing boundary layer disruption. An increased winglet width ratio (w/W) significantly enhances the fluid mixing effect by expanding the lateral coverage, thereby reducing thermal resistance and enhancing heat transfer between the pipe wall and the fluid. In terms of flow resistance characteristics, a greater winglet depth ratio directly leads to an increased longitudinal size of the cutting winglet. This strengthens the disturbance of fluid, resulting in increased boundary layer separation and greater eddy losses. Similarly, an increased winglet width ratio leads to greater lateral flow resistance, so that the fluid needs to overcome a larger shear force and higher collision losses. This leads to an increased friction coefficient (f). In the current study, the heat transfer rate of a pipe equipped with I-RTTWs is about 7 to 26% and 68 to 99% higher than that of a pipe equipped with typical tape (TT) and the plain tube, respectively. The friction coefficient is 1.15–1.37 times and 3.46–4.12 times that of a TT and plain tube, respectively. The comprehensive thermal performance index of the pipe with an I-RTTW is as high as 1.29. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Experimental investigation and ANN prediction of heat transfer enhancement in a heat exchanger tube utilizing twin corrugated twisted tapes(2025-12-01) ;Du, Y. ;Wongcharee, K.; ; Chamoli, S.This report introduces a novel twin-corrugated twisted tape (TC-TT) insert designed to enhance heat transfer in exchanger tubes. The key innovation lies in the twin-corrugated structure, which generates a twin-swirl flow effect. The corrugated surface synergistically increases flow disturbance and expands the effective heat transfer area. The studied parameters were twist ratios (y/w = 3.0, 3.5, and 4.0) and corrugation angles (θ = 45°, 60°, 75°, and 90°) at 6,000 ≤ Re ≤ 20,000. The results show that using twin-corrugated twisted tapes increases the average Nusselt number by roughly 60–135% compared to a plain tube and by 16–35% compared to a conventional single-twisted tape, confirming the effectiveness of this structural modification. This enhancement is primarily due to the combination of double swirling-flows and enhanced effective heat transfer generated by the corrugated surface. Reducing the corrugation angle (θ) and twist ratio (y/w) led to increases in the Nusselt number (Nu), friction factor (f), and thermal performance factor (TPF). Within the studied range, the Nusselt number, friction factor, and thermal performance factor reached maximum values of 5.18, 0.153, and 1.44, respectively, at a twist ratio of 3.0, a corrugation angle of 45°, and Re = 6,000. Regression analysis was utilized to develop correlations for the Nu and f, considering the Re, Pr, y/w, and θ as influencing variables. The proposed correlations for predicting the friction factor and Nusselt number have errors within ±3% and ±2%, respectively. In addition, an artificial neural network (ANN) was developed for predicting the thermal performance values occurring below the experimental study range. The optimal state ANN model shows remarkable prediction accuracy with R<sup>2</sup> of 0.965. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal performance of heat exchanger tube installed with triple twisted-tapes(2020-09-01) ;Samutpraphut, B. ;Promthaisong, P. ;Wongcharee, K. ;Eiamsa-Ard, S.A current study deals with the numerical analysis of heat transfer intensification, flow-thermal fields, local heat transfer distribution, friction factor and thermal performance behavior of the heat exchanger tubes installed with triple twisted tapes. Each set of triple twisted tapes consists of three twisted tapes having an identical twist ratio. Twisted tapes of interest have three different twisted ratios (y/w = 1.0, 1.5 and 2.0). Simulation was performed for the turbulent flow with Reynolds numbers (Re) ranging from 5000 to 20,000. Numerical results indicate that the use of triple twisted-tapes leads to heat transfer enhancement. Nusselt number (Nu) and friction factor (f) increase while thermal performance factor () decreases with decreasing twist ratio of triple twisted tapes. The Nusselt numbers of the tubes installed with triple twisted-tapes having twist ratios of 1.0, 1.5 and 2.0 are higher than those of the plain tube by around 3.34-4.45, 2.75-3.65 and 2.56-3.41 times, respectively. Friction factors (f) of the tubes installed triple twisted-tapes with twist ratios of 1.0, 1.5 and 2.0 are increased up to 46.1-49.7, 24.16-26.04 and 15.86-17.09 times, respectively, as compared to those of the plain tube. The maximum thermal performance factors of 1.21, 1.23 and 1.32 are obtained by using triple twisted tapes with y/w = 1.0, 1.5 and 2.0 at the Reynolds number of 5000.