Jayranaiwachira, Nuthvipa
Loading...
Preferred name
Jayranaiwachira, Nuthvipa
Main Affiliation
Email
nuthvipa.ja@kmitl.ac.th
Now showing 1 - 3 of 3
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Analysis of exergy and heat transfer in a tube fitted with flapped V-baffles(2024-07-01); ; ;Tongyote, Paritkavin ;Skullong, SompolNakhchi, Mahdi ErfanianVortex generator is a device that shows promise in generating streamwise vortices that can be utilized for boosting the rate of heat transmission inside a cooling/heating system with a relatively smaller penalty in terms of friction loss. The primary goal of the current research is to maximize the comparative Nusselt number ratio (Nu/Nu<inf>0</inf>) to be as large as possible to lower the size of the system while keeping thermal performance as high as feasible to save more energy. Thus, in the current study, the impacts of inserting the flapped V-baffle vortex generator (FBVG) on the thermal effectiveness improvement of a round tube were experimentally investigated. At a fixed attack angle (α = 60°) and baffle blockage ratio (B<inf>R</inf> = b/D = 0.3), the geometrical behaviors of FBVGs placed periodically along two edges of a straight tape were six different flap angles (θ = 0°, 25°, 35°, 45°, 65° and 90°) and three ratios of baffle pitches (P/D = P<inf>R</inf> = 2.0, 1.5, and 1.0). The current V-baffles, which were positioned on both tape edges, were designed to reduce friction loss caused by interrupting the central core flow when placed on both tape sides. The measurement results focused on the friction loss and thermal behaviors, including exergy and entropy analyses for Reynolds number from 4750 to 29,270. In the findings, the Nusselt number and friction factor of FBVG at θ = 0° and P<inf>R</inf> = 1 are, respectively, up to 5.6 and 35.24 times larger than those of the smooth tube. The entropy generation (S˙<inf>gen</inf><sup>′</sup>) seems to decline as θ and P<inf>R</inf> increase, with the smallest S˙<inf>gen</inf><sup>′</sup> found at θ = 0° and P<inf>R</inf> = 1 for lower Re. The FBVG has the greatest exergy efficiency (η<inf>Ex</inf>) at θ = 0° and P<inf>R</inf> = 1. To find the true benefits of FBVG, its thermal performance is estimated and seen to reach a maximum at about 2.44 with Nu<inf>R</inf> = 4.65 at θ = 45° and P<inf>R</inf> = 1. The optimal scenario at θ = 25° and P<inf>R</inf> = 1 was preferred, however, since it yielded the largest Nu<inf>R</inf> = 5.42 at TEF = 2.39. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal effectiveness analysis of heat exchange tube with staggered louver-punched V-baffles(2024-12-01); ; ;Promthaisong, Pitak ;Nakhchi, Mahdi ErfanianSkullong, SompolAn experiment has been conducted to ascertain the optimal approach for enhancing the convective transmission of heat in a heat exchanger tube by periodically positioning staggered louver-punched V-baffle (SLVB) vortex generators on a perforated tape. The louver-punched V-baffles were staggered and set up with two patterns: V-apex directing upstream (VU) and downstream (VD), and each featured a louver-punched aperture to minimize friction loss. The aim of this work was to rise the thermal effectiveness as well as the Nusselt number ratio (Nu<inf>R</inf>) at optimal effectiveness in order to cut down on overall dimension of heat exchangers. Consequently, the research findings focused on behaviors of heat transmission and frictional loss, incorporating generated entropy, through a variety of Reynolds numbers (Re) spanning 29,270 to 4762. The SLVB elements were designed and placed in VU and VD forms using three relative pitches (P<inf>R</inf> = 0.5, 1.0, and 1.5) as well as six louver-flapped angles (θ = 0°, 10°, 20°, 30°, 45°, and 90°), all at the same attack angle (α = 52°), a baffle height ratio (B<inf>R</inf> = 0.3) and a louver size ratio (L<inf>R</inf> = 0.73). As demonstrated by the experiment, the θ = 20° generated the best heat transfer of all P<inf>R</inf> values, up to 6.55 times greater than the smooth tube, despite having a lower friction loss than the θ = 0° (solid baffle). At P<inf>R</inf> = 0.5, θ = 20° and smaller Re, the optimum thermal effectiveness factor (TEF) and Nu<inf>R</inf> values were, respectively, about 2.65 and 6.55 for the VU SLVB and 2.52 and 6.04 for the VD one. It implied that the TEF strategies can be utilized to anticipate the best effectiveness under identical scenarios. Also, correlations for the critical parameters, namely, Nu, f, and TEF, were estimated and documented. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Heat transfer analysis in a tube contained with louver-punched triangular baffles(2024-06-01); ; ;Promthaisong, Pitak ;Nakhchi, Mahdi ErfanianSkullong, SompolThe present research assesses the thermal effectiveness of a heat exchange tube incorporating louver-punched triangular baffle (LPTB) vortex generators under turbulent conditions. For Reynolds numbers between 4760 and 29,270, the heat transfer and flow behaviors in the consistent heat-fluxed tube equipped with LPTBs were studied numerically and experimentally. A single baffle height/blockage ratio (b/D = B<inf>R</inf> = 0.25) and relative baffle pitch (P/D = P<inf>R</inf> = 1) were used for both baffle attack angles, (α) 30° and 45°, along with three louver size ratios (e/b = L<inf>R</inf> = 0.24–0.56) as well as five louver angles (θ = 0°, 20°, 30°, 45°, 60°, and 90°). The results show that as the L<inf>R</inf> and θ values decrease, the Nusselt number (Nu) and friction factor (f) of the LPTB rise owing to the improved fluid mixing process generated by streamwise vortices with stronger turbulence kinetic energy. The LPTB with L<inf>R</inf> = 0 and θ = 0° provides the greatest f and Nu of about 22.18 and 5.1 times, respectively, although the one with L<inf>R</inf> = 0.24 and θ = 45° has the largest TEF of about 2.39 and 2.5 for the α = 30° and 45° LPTBs, respectively. Furthermore, an examination into the thermal and flow patterns was conducted through a three-dimensional computation; the validation of the numerical and experimental data yielded satisfactory results. Using measured data, the f and Nu correlations of the α = 30° and 45° LPTBs were additionally established.
