Jayranaiwachira, Nuthvipa
Loading...
Preferred name
Jayranaiwachira, Nuthvipa
Main Affiliation
Email
nuthvipa.ja@kmitl.ac.th
4 results
Now showing 1 - 4 of 4
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Augmented thermal effectiveness in solar air receiver with flapped curved winglets: Experimental and numerical analysis(2025-12-01) ;Sripattanapipat, Somchai; ; ;Promthaisong, PitakNakhchi, Mahdi ErfanianThermal effectiveness was examined on a solar air receiver equipped with a new lengthwise vortex generator, namely a flapped curved winglet (FCW) mounted on the absorber, utilizing experimental and numerical approaches. Two arrays were employed to assemble two FCWs on the absorber at an angle of attack (α = 59.5°). The FCWs' V-tips were orientated upstream (VU-FCW) and downstream (VD-FCW). Air served as the working fluid, entering a constantly heat-fluxed channel at Reynolds numbers (Re) varying from 5280 to 22,510. Three relative winglet pitches (P<inf>R</inf> = P/H = 1.0–2.0), five winglet-mounted flap angles (β = 0° - 90°), and one winglet blockage ratio (b/H=B<inf>R</inf> = 0.6) were among the major factors. According to the findings, lowering P<inf>R</inf> and β greatly enhances the f (friction factor) and Nu (Nusselt number) of the two FCW arrays. The FCW with P<inf>R</inf> = 1.0 and β = 0° has the largest Nu and f values, approximately 8.3 and 77.39 times bigger than the smooth flat channel, as per the test data. The maximal thermal effectiveness factors (TEF) of the VD-FCW and VU-FCW were approximately 2.83 and 2.61, respectively, at comparable β = 45° and P<inf>R</inf> = 1.5. The f and Nu correlations in employing FCW were also provided. A 3D computational analysis employing the realizable k-ε turbulence model was conducted to examine heat transmission and flow patterns, with the corresponding measured data validating the expected results. The numerical and measured data sets yielded consistent results, and the FCW's heat transmission mechanism was also described. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Effect of louvered curved-baffles on thermohydraulic performance in heat exchanger tube(2023-02-01); ; ; ;Promthaisong, PitakSkullong, SompolThe paper presents an experimental study of convection enhancement in a tube heat exchanger using louvered curved-baffle (LCB) vortex generator (VG). The heat transfer and pressure loss of air as a working fluid, flowing in an isothermal-fluxed tube were measured having Reynolds numbers (Re) between 4760 and 29,300. The LCB elements were arrayed on two tape sides in a V-shape with a 30° attack angle. At a fixed baffle height, the LCB had three axial pitch ratios (PR) from 0.5 to 1.5 and six louver angles (θ) from 0° to 90°. Thermal enhancement factor (TEF), Nusselt number (Nu), and friction factor (f) are often utilized to analyze the effect of VG geometrical variables on thermohydraulic performance. The measured results demonstrated that the LCB-inserted tube has a significantly larger Nu and f than a plain tube functioning alone, and that the Nu and f tend to rise when PR and θ decline. Using the LCB increases Nu and f by approximately 2.59-4.66 and 3.8-39.37 times, respectively. The maximal TEF is achieved for the LCB at PR = 1, θ = 45° and lower Re. Empirical correlations for Nu and f were evaluated and found to fit measured data well, with discrepancies by ± 9% and ±10%, respectively. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal effectiveness analysis of heat exchange tube with staggered louver-punched V-baffles(2024-12-01); ; ;Promthaisong, Pitak ;Nakhchi, Mahdi ErfanianSkullong, SompolAn experiment has been conducted to ascertain the optimal approach for enhancing the convective transmission of heat in a heat exchanger tube by periodically positioning staggered louver-punched V-baffle (SLVB) vortex generators on a perforated tape. The louver-punched V-baffles were staggered and set up with two patterns: V-apex directing upstream (VU) and downstream (VD), and each featured a louver-punched aperture to minimize friction loss. The aim of this work was to rise the thermal effectiveness as well as the Nusselt number ratio (Nu<inf>R</inf>) at optimal effectiveness in order to cut down on overall dimension of heat exchangers. Consequently, the research findings focused on behaviors of heat transmission and frictional loss, incorporating generated entropy, through a variety of Reynolds numbers (Re) spanning 29,270 to 4762. The SLVB elements were designed and placed in VU and VD forms using three relative pitches (P<inf>R</inf> = 0.5, 1.0, and 1.5) as well as six louver-flapped angles (θ = 0°, 10°, 20°, 30°, 45°, and 90°), all at the same attack angle (α = 52°), a baffle height ratio (B<inf>R</inf> = 0.3) and a louver size ratio (L<inf>R</inf> = 0.73). As demonstrated by the experiment, the θ = 20° generated the best heat transfer of all P<inf>R</inf> values, up to 6.55 times greater than the smooth tube, despite having a lower friction loss than the θ = 0° (solid baffle). At P<inf>R</inf> = 0.5, θ = 20° and smaller Re, the optimum thermal effectiveness factor (TEF) and Nu<inf>R</inf> values were, respectively, about 2.65 and 6.55 for the VU SLVB and 2.52 and 6.04 for the VD one. It implied that the TEF strategies can be utilized to anticipate the best effectiveness under identical scenarios. Also, correlations for the critical parameters, namely, Nu, f, and TEF, were estimated and documented. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Heat transfer analysis in a tube contained with louver-punched triangular baffles(2024-06-01); ; ;Promthaisong, Pitak ;Nakhchi, Mahdi ErfanianSkullong, SompolThe present research assesses the thermal effectiveness of a heat exchange tube incorporating louver-punched triangular baffle (LPTB) vortex generators under turbulent conditions. For Reynolds numbers between 4760 and 29,270, the heat transfer and flow behaviors in the consistent heat-fluxed tube equipped with LPTBs were studied numerically and experimentally. A single baffle height/blockage ratio (b/D = B<inf>R</inf> = 0.25) and relative baffle pitch (P/D = P<inf>R</inf> = 1) were used for both baffle attack angles, (α) 30° and 45°, along with three louver size ratios (e/b = L<inf>R</inf> = 0.24–0.56) as well as five louver angles (θ = 0°, 20°, 30°, 45°, 60°, and 90°). The results show that as the L<inf>R</inf> and θ values decrease, the Nusselt number (Nu) and friction factor (f) of the LPTB rise owing to the improved fluid mixing process generated by streamwise vortices with stronger turbulence kinetic energy. The LPTB with L<inf>R</inf> = 0 and θ = 0° provides the greatest f and Nu of about 22.18 and 5.1 times, respectively, although the one with L<inf>R</inf> = 0.24 and θ = 45° has the largest TEF of about 2.39 and 2.5 for the α = 30° and 45° LPTBs, respectively. Furthermore, an examination into the thermal and flow patterns was conducted through a three-dimensional computation; the validation of the numerical and experimental data yielded satisfactory results. Using measured data, the f and Nu correlations of the α = 30° and 45° LPTBs were additionally established.
