Promvonge, Pongjet
Loading...
Preferred name
Promvonge, Pongjet
Alternative Name
Promvonge, P.
Main Affiliation
Email
pongjet.pr@kmitl.ac.th
21 results
Now showing 1 - 10 of 21
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Numerical heat transfer study of square duct equipped with novel flapped V-baffles(2024-03-01); ; ;Skullong, Sompol ;Promthaisong, PitakNakhchi, Mahdi ErfanianThe paper describes a computational study of heat transfer enhancement inside a square duct with V-shaped flapped baffles located repeatedly on the bottom and top walls for fluid flowing with Reynolds numbers (Re) from 3000 to 21,000. The basic goal of this work is to attain the largest relative Nusselt number (Nu/Nu<inf>0</inf>) whilst maintaining the highest thermal performance to improve energy savings. A finite volume method was used in the computations, along with the Realizable k‒ε turbulent model. The variable baffle parameters considered first in the current simulation were the relative height/blockade ratio (B<inf>R</inf> = 0.05−0.2) and the flap angle of the baffle hole (β = 0° − 90°), while the fixed parameters included the attack angle (α = 60°), hole diameter ratio (d<inf>R</inf> = 0.5), and pitch ratio (P<inf>R</inf> = 0.5). To accomplish this goal, the previously mentioned parameters providing the best thermal performance were investigated further by extending the values of B<inf>R</inf> to 0.25−0.3, d<inf>R</inf> to 0.8 and α to 45°−30°. The simulation results indicate that the jet flowing from the flapped hole, as well as the vortices created by the baffle, can boost heat transfer and friction loss in comparison to the plain duct. In comparison, using a flapped baffle with β > 0° results in less friction loss, a greater thermal enhancement factor (TEF), and a higher Nusselt number than using a baffle with no flap. The first investigation disclosed that for B<inf>R</inf> = 0.2 and β = 20°, the greatest TEF of 2.19 with Nu/Nu<inf>0</inf> of 7.9 times are obtained. The extended study, on the other hand, showed that the highest TEF of roughly 2.49 with Nu/Nu<inf>0</inf> of 8.4 times are seen for α = 45°, d<inf>R</inf> = 0.8, B<inf>R</inf> = 0.25 and β = 20° at lowest Re. Thus, the flapped baffle provides a significant increase in Nu/Nu<inf>0</inf> and TEF over the baffle alone. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Augmented thermal effectiveness in solar air receiver with flapped curved winglets: Experimental and numerical analysis(2025-12-01) ;Sripattanapipat, Somchai; ; ;Promthaisong, PitakNakhchi, Mahdi ErfanianThermal effectiveness was examined on a solar air receiver equipped with a new lengthwise vortex generator, namely a flapped curved winglet (FCW) mounted on the absorber, utilizing experimental and numerical approaches. Two arrays were employed to assemble two FCWs on the absorber at an angle of attack (α = 59.5°). The FCWs' V-tips were orientated upstream (VU-FCW) and downstream (VD-FCW). Air served as the working fluid, entering a constantly heat-fluxed channel at Reynolds numbers (Re) varying from 5280 to 22,510. Three relative winglet pitches (P<inf>R</inf> = P/H = 1.0–2.0), five winglet-mounted flap angles (β = 0° - 90°), and one winglet blockage ratio (b/H=B<inf>R</inf> = 0.6) were among the major factors. According to the findings, lowering P<inf>R</inf> and β greatly enhances the f (friction factor) and Nu (Nusselt number) of the two FCW arrays. The FCW with P<inf>R</inf> = 1.0 and β = 0° has the largest Nu and f values, approximately 8.3 and 77.39 times bigger than the smooth flat channel, as per the test data. The maximal thermal effectiveness factors (TEF) of the VD-FCW and VU-FCW were approximately 2.83 and 2.61, respectively, at comparable β = 45° and P<inf>R</inf> = 1.5. The f and Nu correlations in employing FCW were also provided. A 3D computational analysis employing the realizable k-ε turbulence model was conducted to examine heat transmission and flow patterns, with the corresponding measured data validating the expected results. The numerical and measured data sets yielded consistent results, and the FCW's heat transmission mechanism was also described. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Enhanced thermal effectiveness of square duct with V-type double-baffles: Numerical study(2024-09-01); ;Sripattanapipat, Somchai; ;Skullong, SompolPromthaisong, PitakThe article puts forward three-dimensional computational research on heat transmission augmentation within a square channel containing 45<sup>o</sup> V-type double-baffles positioned on the lower and top parts at regular intervals in the turbulence zone for Reynolds numbers (Re) that vary from 3000 to 20,000. The primary goal of this research is to increase the thermal effectiveness and relative Nusselt number (Nu/Nu<inf>0</inf>), in order to conserve energy and reduce the size of the heating or cooling system. The simulations utilize a finite volume approach in common with the SIMPLE algorithm, whereas the turbulent model used is the realizable k–ε. The baffles are designed to be separated vertically for reducing pressure loss. Both single V-baffles and double V-baffles have four relative pitches (PR = 0.4, 0.5, 0.6, and 1.0) and height/blockage ratios (BR = 0.05, 0.1, 0.15, and 0.2), with a fixed attack angle (α) of 45<sup>o</sup>. The computational findings show that both V-baffles are capable of producing the primary vortices, but only the double V-baffles have the ability to provide the impinging streams onto the wall, cooling the region behind the baffles. This suggests that the double V-baffles not only boost heat transmission but also reduce frictional loss. When compared to a single V-baffle, the double ones enhance heat transfer by an average of 1.04–9.94% while decreasing frictional loss by an average of 9.88–31.73%. The thermal effectiveness factor (TEF) of the double V-baffles ranges from 1.03 to 3.21, and its peak value of around 3.21 is for PR = 0.4, BR = 0.05, at lower Re. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Experimental and numerical thermal performance in solar receiver heat exchanger with trapezoidal louvered winglet and wavy groove(2022-04-01); ;Promthaisong, PitakSkullong, SompolA numerical and experimental study on the thermal–hydraulic performance of a solar receiver heat exchanger (SRH) equipped with a newly designed longitudinal-vortex generator, namely, trapezoidal louvered winglet and wavy groove placed on the absorber has been carried out. The relevant parameters included three pitch ratios of winglets/grooves (P/H = P<inf>R</inf> = 1, 1.5 and 2), four winglet blockage ratios (b/H = B<inf>R</inf> = 0.3–0.45) at a single attack angle of winglet/groove, α = 45°. The experimental outcome showed that the trapezoidal winglet (TW) together with the wavy groove at P<inf>R</inf> = 1, B<inf>R</inf> = 0.45 gives the greatest friction factor and the heat transfer around 108.1 and 9.35 times over the smooth SRH channel, respectively while that at P<inf>R</inf> = 1.5, B<inf>R</inf> = 0.4 provides the optimal thermal performance at about 2.6. To increase further the performance, the TW at optimal conditions was modified by punching the TW at its centroid to be a square-hole and then covering the back-end hole partially like a louver, called the trapezoidal louvered winglet (TLW). The TLW elements were mounted on the grooved absorber plate with eight louver angles (θ = 0°–90°). The investigation indicated that among the louver angles, the θ = 20° yields the greatest heat transfer up to 9.18 times above the smooth SRH whilst its friction loss is lower than the θ = 0°(solid-winglet). Hence, the TLW and wavy groove at θ = 20° provided the maximum thermal–hydraulic performance around 2.76. To understand the flow and thermal patterns, a 3D flow computation was also carried out and their results were validated with available measurements. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermo-Hydraulic Performance of a Heat Exchanger Tube with Inserted Curved-Wing Tape Vortex Generators(2024-10-24) ;Koolnapadol, Narin; ;Promthaisong, Pitak ;Hoonpong, PanuwatKhanoknaiyakarn, ChitakornIn the current study, thermal patterns and flow resistance in a heat exchange tube equipped with a curved-wing tape (CWT) vortex generator were experimentally analyzed to boost performance. A range of Reynolds numbers (Re) from 4130 to 25,370 was utilized in the experiment. The curved wings were arranged in forward array patterns for pitch length ratios (P/D = PR = 2.5, 2, and 1.5) and three wing attack angles (α = 10°, 20°, and 30°). The friction factor, f, and the Nusselt number, Nu, were utilized to quantify the pressure loss and heat transmission caused by the CWT insertion. The measured data reveal that utilizing the CWT resulted in a roughly 2.55-4.37 times greater increase in Nu than the smooth tube, whereas the rise in f is approximately 7.36-46.9 times. Raising the α value causes the Nu and f to trend upward, but increasing PR causes them to trend downward. The CWT's maximal thermal performance is approximately 1.58 at α = 10<sup>o</sup> and PR = 1.5. Correlations for f and Nu in the functional form of the CWT parameters have also been established. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal performance in solar air heater with perforated-winglet-type vortex generator(2018-08-01) ;Skullong, Sompol ;Promthaisong, Pitak; ; An experimental and numerical study of turbulent convective heat transfer in a solar air heater duct with winglet-type vortex generators (WVGs) placed on the absorber plate is presented. Air as the test fluid enters the duct having a uniform wall heat-flux applied on the upper wall or the absorber plate with Reynolds number from 4100 to 25,500. Two types of WVGs are introduced: rectangular (RWVG) and trapezoidal (TWVG) WVGs, in order to create multiple vortex flows along the duct. The WVG parameters in the present study include two relative height (B<inf>R</inf> = e/H = 0.2 and 0.48), three longitudinal pitch ratios (P<inf>R</inf> = P<inf>l</inf>/H = 1, 1.5 and 2) and a single attack angle, α = 30°. The experimental result reveals that the RWVG with B<inf>R</inf> = 0.48 and P<inf>R</inf> = 1 provides the highest heat transfer and friction factor at about 7.1 and 109.5 times above the flat duct, respectively while the TWVG with B<inf>R</inf> = 0.2 and P<inf>R</inf> = 1.5 yields the maximum thermal performance around 1.84. Then, to improve the performance by reducing the substantial pressure loss, both the WVGs with B<inf>R</inf> = 0.48 and P<inf>R</inf> = 1.5 are modified to be perforated rectangular and trapezoidal winglet-type vortex generators (P-RWVG and P-TWVG) with four different punched hole/pore diameters (d = 1, 3, 5 and 7 mm) on their central area. The investigation indicates that among the perforated WVGs, the P-RWVG at d = 1 mm yields the highest heat transfer and friction factor up to 6.78 and 84.32 times higher than the smooth duct but the best thermal performance of about 2.01 is found for the P-TWVG with d = 5 mm. To explore the flow and heat transfer pattern, a 3D numerical flow simulation is performed and validated with available measurements where both the numerical and measured results are in good agreement. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal performance evaluation of a diamond-shaped roughened tube(2025-12-01) ;Chokphoemphun, Suriya ;Kamma, Panit; Promthaisong, PitakThermal performance evaluation was examined numerically in a diamond-shaped roughened tube, which created recirculation and pair counter-rotation flows, which helped to disrupt the boundary layer, and increased fluid mixing led to improving the rate of heat transfer. The parameters studied, including relative depth ratio, e/D, DR, from 0.02 ≤ DR ≤ 0.14, and relative pitch ratio, p/D, PR, from 0.25 ≤ PR ≤ 1.5, under turbulent flow conditions, 3000 ≤ Re ≤ 20,000. Computed results included heat transfer (Nu/Nu<inf>0</inf>), frictional loss (f/f<inf>0</inf>) and thermal performance (in terms of thermal enhancement factor, TEF). The simulations showed that the velocity and heat transfer became fully developed periodic at around x/D ≈ 6–7.5. The pair counter-rotation flows increased the level of both the flow strength and the mixing of fluid, and disrupted the boundary layer, leading to an increase in heat transfer rate. The Nu/Nu<inf>0</inf>, f/f<inf>0</inf> and TEF were achieved in a range of 1.00–3.34, 1.21–24.00 and 0.69–1.56. The maximum TEF was found at 1.56 for DR = 0.08, PR = 0.50 and Re = 5000. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Heat transfer augmentation in solar heat exchanger duct with louver-punched V-baffles(2022-12-01); ;Promthaisong, PitakSkullong, SompolA vortex generator's ability to create secondary flow and accelerate rapid fluid mixing allows it to effectively improve thermal performance in a solar heat exchanger duct. A newly created louver-punched V-baffle (LPVB) vortex generator was tested experimentally in the current study and the flow and thermal patterns were also investigated using a three-dimensional CFD simulation. The Realizable k–ε turbulence model was utilized in the simulation and the predictions were verified using experimental data and correlations. By directing the impinging air onto the duct's heated surface, the square louver on the baffle served the primary function of reducing pressure drag. Air was used as the test fluid, flowing at Reynolds numbers (Re) from 5300 to 23,000 into the constant heat-fluxed duct. On the heated wall that was set up by letting the V-apex direct upstream, the LPVBs with a 45° attack angle (α) were repeatedly positioned. There were two aspects to the current investigation. First, the optimal relative baffle pitches (P<inf>R</inf>) and louver angles (β) conditions were determined by looking at the LPVB characteristics, which included four β and three P<inf>R</inf> at a fixed relative louver size (L<inf>R</inf> = 0.5) and baffle height (B<inf>R</inf> = 0.4). Second, three relative louver sizes (L<inf>R</inf> = 0.3–0.9) were investigated at the optimal P<inf>R</inf> and β. According to the results, the solid-baffle friction loss is significantly reduced by the LPVB with β > 0° while the heat transfer is slightly lower. In the first part, the LPVB with P<inf>R</inf> = 1.5, β = 45° has the optimal performance while in the second part, the one with L<inf>R</inf> = 0.9 yields the greatest performance. A numerical flow model was computed to understand the flow and thermal patterns. The findings were verified using the available measurements, and there is close agreement between the experimental and numerical results. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Experimental and numerical heat transfer study of turbulent tube flow through discrete V-winglets(2020-04-01); ;Promthaisong, PitakSkullong, SompolThe article presents an experimental and numerical investigation on heat transfer augmentation in a tubular heat exchanger inserted with discrete-V-winglet (DW) tape. Air entered the DW-inserted tube having a uniform wall heat flux in a turbulent flow regime, Reynolds number from 4200 to 25,800. Two arrangements of DWs: V-tip pointing upstream (V-up) and downstream (V-down) were introduced with three relative winglet heights (R<inf>B</inf>=b/D = 0.1, 0.15 and 0.2) and four relative winglet-pitches (R<inf>P</inf>=P/D = 0.5, 1.0, 1.5 and 2.0), all at a single angle of attack, α = 30°. Effects of those parameters on the heat transfer/Nusselt number (Nu) and friction factor (f) were examined. Also, a novel thermal-performance enhancement factor (TEF) was put forward. The experimental result has shown that at a given R<inf>B</inf>, the smallest pitch length (R<inf>P</inf>=0.5) yields the highest f and Nu. The DW with R<inf>B</inf>=0.2 and R<inf>P</inf>=0.5 has the maximum Nu and f of about 3.8 times and 18.8 times, respectively whereas the one with R<inf>B</inf>=0.15 and R<inf>P</inf>=1.0 gives the highest TEF of about 1.99 and 2.02 for the V-up and V-down, respectively. Moreover, the DW provides higher TEF than the typical V-winglet as expected. To explore the mechanism of heat transfer, a numerical model of the inserted-tube flow was carried out and the numerical result was validated and found in favorable agreement with available measurement. Flow structures and heat transfer patterns from the simulation such as temperature contours and streamlines including the Nusselt number contours were also proposed. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Effect of louvered curved-baffles on thermohydraulic performance in heat exchanger tube(2023-02-01); ; ; ;Promthaisong, PitakSkullong, SompolThe paper presents an experimental study of convection enhancement in a tube heat exchanger using louvered curved-baffle (LCB) vortex generator (VG). The heat transfer and pressure loss of air as a working fluid, flowing in an isothermal-fluxed tube were measured having Reynolds numbers (Re) between 4760 and 29,300. The LCB elements were arrayed on two tape sides in a V-shape with a 30° attack angle. At a fixed baffle height, the LCB had three axial pitch ratios (PR) from 0.5 to 1.5 and six louver angles (θ) from 0° to 90°. Thermal enhancement factor (TEF), Nusselt number (Nu), and friction factor (f) are often utilized to analyze the effect of VG geometrical variables on thermohydraulic performance. The measured results demonstrated that the LCB-inserted tube has a significantly larger Nu and f than a plain tube functioning alone, and that the Nu and f tend to rise when PR and θ decline. Using the LCB increases Nu and f by approximately 2.59-4.66 and 3.8-39.37 times, respectively. The maximal TEF is achieved for the LCB at PR = 1, θ = 45° and lower Re. Empirical correlations for Nu and f were evaluated and found to fit measured data well, with discrepancies by ± 9% and ±10%, respectively.
