Item type:Publication, Numerical simulation of Al2O3-water nanofluid flow and heat transfer in a tube with angled rings(2014-01-01); ;Sripattanapipat, SomchaiA numerical investigation has been conducted to examine turbulent flow and heat transfer characteristics in a three-dimensional isothermal tube mounted with 60° angled rings (AR). The ARs with pitch spacing ratio, PR=1.0 and various blockage ratios (BR) ranging from 0.025-0.1 are introduced. The computations are based on a finite volume method and the SIMPLE algorithm has been implemented. The fluid flow and heat transfer characteristics are presented for Reynolds number (Re) ranging from 3000 to 12000. To generate a main counter-vortex pair flow in the tube, ARs at an attack angle of 60° are mounted repeatedly in the tube. Effect of different BRs at a single PR and nanofluid, Al<inf>2</inf>O<inf>3</inf>-water, with volume fractions 1% and 5% on heat transfer and friction loss is investigated. It is apparent that two main vortex flows created by the ARs exist and help to induce impinging flows on the tube wall leading to drastic increase in heat transfer rate over the tube. The increment in the BR gives rise to the increase in the Nusselt number and friction factor. The computational results reveal that the maximum thermal enhancement factor for the AR with BR=0.025 is found to be 1.8 at Re =3000. The results show that nanofluid, Al<inf>2</inf>O<inf>3</inf> -water, can increase the thermal performance when increasing volume fraction to 5%. © (2014) Trans Tech Publications, Switzerland. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Augmented thermal effectiveness in solar air receiver with flapped curved winglets: Experimental and numerical analysis(2025-12-01) ;Sripattanapipat, Somchai; ; ;Promthaisong, PitakNakhchi, Mahdi ErfanianThermal effectiveness was examined on a solar air receiver equipped with a new lengthwise vortex generator, namely a flapped curved winglet (FCW) mounted on the absorber, utilizing experimental and numerical approaches. Two arrays were employed to assemble two FCWs on the absorber at an angle of attack (α = 59.5°). The FCWs' V-tips were orientated upstream (VU-FCW) and downstream (VD-FCW). Air served as the working fluid, entering a constantly heat-fluxed channel at Reynolds numbers (Re) varying from 5280 to 22,510. Three relative winglet pitches (P<inf>R</inf> = P/H = 1.0–2.0), five winglet-mounted flap angles (β = 0° - 90°), and one winglet blockage ratio (b/H=B<inf>R</inf> = 0.6) were among the major factors. According to the findings, lowering P<inf>R</inf> and β greatly enhances the f (friction factor) and Nu (Nusselt number) of the two FCW arrays. The FCW with P<inf>R</inf> = 1.0 and β = 0° has the largest Nu and f values, approximately 8.3 and 77.39 times bigger than the smooth flat channel, as per the test data. The maximal thermal effectiveness factors (TEF) of the VD-FCW and VU-FCW were approximately 2.83 and 2.61, respectively, at comparable β = 45° and P<inf>R</inf> = 1.5. The f and Nu correlations in employing FCW were also provided. A 3D computational analysis employing the realizable k-ε turbulence model was conducted to examine heat transmission and flow patterns, with the corresponding measured data validating the expected results. The numerical and measured data sets yielded consistent results, and the FCW's heat transmission mechanism was also described. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Heat transfer in solar air duct with multi-V-ribbed absorber and grooved back-plate(2021-04-01); ;Khanoknaiyakarn, Chitakorn ;Sripattanapipat, SomchaiSkullong, SompolThe article presents an experimental study on heat transfer and friction behaviors in a solar air duct fitted with multiple V-shaped ribs on the absorber and delta-grooves on the back plate. Measurements were carried out in the test duct having a cross-section of width, W = 300 mm and height, H = 27 mm. The air flow rate inside the duct was varied to have Reynolds numbers based on the duct hydraulic diameter from about 7000 to 30,000. Two vortex flow devices: rib and groove turbulators, were introduced to generate the vortex flows along the duct. In the test duct, the upper/absorber plate having a constant heat-flux was mounted repeatedly by multiple V-shaped thin ribs with an attack angle (α) of 45° relative to main flow direction while the lower/back plate was grooved periodically in the delta/triangular shape with an attack angle (θ) of 60°. In the present investigation, the geometrical parameters of the ribs included three different rib- to duct-height ratios (e/H = B<inf>R</inf> = 0.108, 0.162 and 0.217) and three rib-pitch to duct-height ratio (P/H = P<inf>R</inf> = 1.0, 1.5 and 2.0). The experimental results have shown that the duct with the V-ribbed absorber at B<inf>R</inf> = 0.217, P<inf>R</inf> = 1 in conjunction with the delta-grooved back plate has the greatest heat transfer and pressure loss. However, the use of the combined devices with P<inf>R</inf> = 1, B<inf>R</inf> = 0.108 leads to the highest thermal performance and also provides greater heat transfer and thermal performance than employing the V-rib or the delta-groove alone. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Enhanced thermal effectiveness of square duct with V-type double-baffles: Numerical study(2024-09-01); ;Sripattanapipat, Somchai; ;Skullong, SompolPromthaisong, PitakThe article puts forward three-dimensional computational research on heat transmission augmentation within a square channel containing 45<sup>o</sup> V-type double-baffles positioned on the lower and top parts at regular intervals in the turbulence zone for Reynolds numbers (Re) that vary from 3000 to 20,000. The primary goal of this research is to increase the thermal effectiveness and relative Nusselt number (Nu/Nu<inf>0</inf>), in order to conserve energy and reduce the size of the heating or cooling system. The simulations utilize a finite volume approach in common with the SIMPLE algorithm, whereas the turbulent model used is the realizable k–ε. The baffles are designed to be separated vertically for reducing pressure loss. Both single V-baffles and double V-baffles have four relative pitches (PR = 0.4, 0.5, 0.6, and 1.0) and height/blockage ratios (BR = 0.05, 0.1, 0.15, and 0.2), with a fixed attack angle (α) of 45<sup>o</sup>. The computational findings show that both V-baffles are capable of producing the primary vortices, but only the double V-baffles have the ability to provide the impinging streams onto the wall, cooling the region behind the baffles. This suggests that the double V-baffles not only boost heat transmission but also reduce frictional loss. When compared to a single V-baffle, the double ones enhance heat transfer by an average of 1.04–9.94% while decreasing frictional loss by an average of 9.88–31.73%. The thermal effectiveness factor (TEF) of the double V-baffles ranges from 1.03 to 3.21, and its peak value of around 3.21 is for PR = 0.4, BR = 0.05, at lower Re. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Effect of louver-perforated V-type baffles on thermal effectiveness and entropy in round tube(2025-08-01); ;Sripattanapipat, Somchai; ;Nakhchi, Mahdi ErfanianSkullong, SompolAn experimental investigation was conducted to assess the influence of insertion of a louver-perforated V-type baffle (LVB) vortex generator into a consistent heat-fluxed tube on thermal performance. This study aimed to optimize thermal effectiveness to boost energy savings and reduce the heat exchanger size. The experiments focused on investigating the thermal features, as well as estimating the entropy of turbulent flow at Reynolds numbers (Re) varying between 4750 and 29,290. The LVBs were positioned in two different arrays on a supporting tape during the present experiment: “V-down” and “V-up,” with the V-apex oriented upstream and downstream, respectively, at a fixed attack angle (α = 52°). At one relative baffle height (B<inf>R</inf> = 0.3) and pitch (P<inf>R</inf> = 1.0), the LVBs dealt with six louver flapped angles (θ = 0°, 10°, 20°, 30°, 45°, and 90°) in addition to three louver-hole sizes and locations (θ<inf>1</inf>, θ<inf>2</inf> and θ<inf>12</inf>). Comparative analysis was also conducted on data obtained from the current smooth tube. According to the findings, the louver angle θ<inf>1</inf> = 20°, located on the baffle's trailing end, had the greatest relative Nusselt number (Nu<inf>R</inf>), which was 5.9 times for V-down and 6.38 times for V-up. Furthermore, compared to the V-down and V-up solid baffles (θ = 0°), their friction losses were lessened. The V-up LVB reached its minimum value at θ<inf>1</inf> = 20°, corresponding to the lowest Re. At θ<inf>1</inf> = 20°, the V-up LVB attained its minimum entropy generation (S˙<inf>gen</inf><sup>′</sup>) and maximum reduced entropy factor (S<inf>R</inf>) around 20.3. At a comparable θ<inf>1</inf> = 20°, the maximal thermal effectiveness factor (TEF) of V-down and V-up were approximately 2.39 and 2.59, respectively. The estimation and documentation of correlations were also performed for the parameters under consideration, namely Nu, f, and TEF. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Laminar periodic flow and heat transfer in square channel with 45° inline baffles on two opposite walls(2010-06-01); ;Sripattanapipat, SomchaiA numerical investigation has been carried out to examine laminar flow and heat transfer characteristics in a three-dimensional isothermal wall square channel with 45°-angled baffles. The computations are based on the finite volume method, and the SIMPLE algorithm has been implemented. The fluid flow and heat transfer characteristics are presented for Reynolds numbers based on the hydraulic diameter of the channel ranging from 100 to 1000. To generate a pair of mainstreamwise vortex flows through the tested section, baffles with an attack angle of 45° are mounted in tandem and inline arrangement on the lower and upper walls of the channel. Effects of different baffle heights on heat transfer and pressure loss in the channel are studied and the results of the 45° inline baffle are also compared with those of the 90° transverse baffle and the 45° staggered baffle. It is apparent that in each of the main vortex flows, a pair of streamwise twisted vortex (P-vortex) flows created by the 45° baffle exist and help to induce impinging flows on a sidewall and wall of the baffle cavity leading to drastic increase in heat transfer rate over the channel. In addition, the rise in the baffle height results in the increase in the Nusselt number and friction factor values. The computational results reveal that numerical results of both the 45° inline and staggered baffles are nearly the same. The optimum thermal enhancement factor is at the 45° baffle height of 0.2 times of the channel height for both arrays. The maximum thermal enhancement factor of the 45° baffle in the Re range studied is found to be about 2.6 or twice higher than that of the 90° transverse baffle. © 2010 Elsevier Masson SAS. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal effectiveness and entropy-exergy estimation in a tube with punched double V-winglets(2026-06-01); ;Sripattanapipat, Somchai; ;Erfanian Nakhchi, MahdiSkullong, SompolVortex generators are effective devices for enhancing heat transfer rates in heating or cooling systems with minimal frictional losses via the production of streamwise vortices. This research effort presents the perforated double V-winglet (P-DVW) and looks at how it affects heat transmission and friction when mounted inside a heat exchange tube that is consistently heated for producing multiple vortices whereas its flow is turbulent. Optimizing thermal performance for increased energy savings and maximizing the Nusselt number ( Nu ) to minimize heat exchanger size are the major goals. Thermal characteristics, including generated entropy and exergy efficiency, are explored in depth. A Reynolds number (Re) that varies from 4760 to 29,270 is employed to explore the friction and thermal features of the tube. The P-DVW parameters encompass attack angles of α<inf>2</inf> = 15° and α<inf>1</inf> = 30°, four porosity ratios ( A <inf>h</inf>/ A <inf>w</inf> = 0, 0.0188, 0.0523, and 0.1026), and three pitch ratios, P<inf>R</inf>, (0.75, 1, and 1.25), while maintaining a constant winglet height. At P<inf>R</inf> = 0.75 and A <inf>h</inf>/ A <inf>w</inf> = 0, the P-DVW exhibits peak f and Nu values around 23.83 and 5.31 times bigger than those of the plain tube, accordingly. Further, under the specified conditions, it yields minimal entropy production, while the optimal exergy efficiency is roughly 0.9829. The thermal effectiveness of P-DVW is anticipated to reach its maximum at 2.55 with Nu<inf>R</inf> = 4.54 at A <inf>h</inf>/ A <inf>w</inf> = 0.0523 and P<inf>R</inf> = 0.75 to reveal its actual benefits. Furthermore, the correlations of f , Nu , and TEF were determined for the examined range of values. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Heat transfer distribution and flow characteristics in a channel with perforated-baffles(2022-11-01) ;Eiamsa-ard, Smith ;Sripattanapipat, Somchai ;Saysroy, Anucha; Maruyama, NaokiThe current paper reports the prediction of heat transfer performance of a channel with a modified perforated-baffle in a square wings (SW-PB) form. Numerical results include flow/temperature field, local heat transfer distribution, and thermal performance of a channel installed with the transverse solid baffle (TB), perforated-baffle (PB), and perforated-baffle with square wings (SW-PB). The simulation results demonstrated that TB brought a large recirculation flow, PB induced small recirculation and SW-PB produced several impinging jets as well as recirculation flows. Heat transfer rates given by PB were lower than those provided by TB and SW-PB by around 6.8% and 7.3%, respectively which were accompanied by lower friction losses by about 11.8% and 3.6%, respectively. Although, SW-PB gave higher heat transfer, the assessment of thermal performance factor (TPF) showed that the benefit from lower friction losses was more important. Under the same pumping power, TPFs assisted by SW-PB were higher than that assisted by PB and TB by 6.0% and 3.3%, respectively. The highest TPF of 1.2 was captured by SW-PB at Re = 9,000. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Numerical Heat Transfer Investigation in a Heat Exchanger Tube with Hexagonal Conical-ring Inserts(2016-11-01) ;Sripattanapipat, Somchai ;Tamna, Sombat; The hexagonal conical rings (HCR) modified from the typical conical ring (CR) are used as a turbulence promoter for producing the vortex flows to enhance the heat transfer rate in a heat exchanger tube. To reduce the pressure loss, the V-shaped HCR (V-HCR) obtained by cutting both symmetric plane of the cone-tip of HCR at 30°, 45°and 60°is offered in the present work. The tube fitted with V-HCR elements having a fixed inlet and outlet diameter is numerically investigated. The computation is carried out for Reynolds number in a range of 3000 to 20,000 in a uniform heat-fluxed test tube. The numerical results show that the V-HCR insert leads to much higher heat transfer than the typical CR/HCR insert or the smooth tube alone and also provides lower friction factor. The 30°V-shaped HCR gives the highest heat transfer and thermal performance due to the lowest friction loss, indicating the promising device of the V-HCR. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Enhanced thermal performance in solar receiver duct with louver-punched V-type winglets: Numerical and experimental study(2025-03-01); ;Sripattanapipat, Somchai ;Promthaisong, Pitak ;Skullong, SompolAn experimental and computational research was performed to explore the augmentation of turbulent convection in a solar receiver channel by utilizing louver-punched V-type winglets (LPVWs) that were fixed to the absorber plate. The simulation utilized the realizable k-ε turbulent model, and the predicated outputs were verified by the relevant measured data. At a fixed attack angle (α) of 45°, the LPVW components were mounted on the absorber with the V-tip facing downstream. Using the LPVW, the newly developed absorber is intended to boost thermal performance by generating multiple flows of longitudinal vortices that induce impinging air streams onto the absorber, thereby enhancing heat transmission. The louvered hole on the winglet serves to reduce pressure loss while preserving the primary vortices. In the current investigation, the winglet parameters consisted of a single relative winglet height (B<inf>R</inf> = 0.4), four louver size ratios (R<inf>L</inf> = e<inf>1</inf>/b = 0.9, 0.7, 0.5, and 0.3), and five louver-flapped angles (β = 90°, 60°, 45°, 30°, and 0°). The LPVW with β > 0° substantially reduced the solid-winglet (β = 0°) friction loss, whereas the heat transmission was slightly declined, as indicated by the results. The solid winglet (β = 0°) exhibited the largest frictional loss and heat transmission, with values approximately 6.3 and 48.2 times the smooth flat duct, respectively. The optimal performance of the LPVW was roughly 2.58, at R<inf>L</inf> = 0.9 and β = 45° Furthermore, empirical correlations for heat transmission and frictional loss were established for this solar receiver duct system. To investigate the heat transmission and flow patterns, a 3-dimensional numerical simulation was implemented, and the predictions were verified against the measured data. The findings were in good accord between the numerical and measured data. For greater thermal performance, the LPVW is reconfigured by altering the locations of the louver holes. The revised LPVW exhibits a peak TEF of 2.7 at β = 35°, l<inf>2</inf>/l<inf>1</inf> = 0.15, l<inf>3</inf>/l<inf>1</inf> = -0.15 and R<inf>L</inf> = 0.9, about 4.65 % superior than the initial analysis.