Now showing 1 - 10 of 27
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Numerical heat transfer study of square duct equipped with novel flapped V-baffles
    (2024-03-01) ; ;
    Skullong, Sompol
    ;
    Promthaisong, Pitak
    ;
    Nakhchi, Mahdi Erfanian
    The paper describes a computational study of heat transfer enhancement inside a square duct with V-shaped flapped baffles located repeatedly on the bottom and top walls for fluid flowing with Reynolds numbers (Re) from 3000 to 21,000. The basic goal of this work is to attain the largest relative Nusselt number (Nu/Nu<inf>0</inf>) whilst maintaining the highest thermal performance to improve energy savings. A finite volume method was used in the computations, along with the Realizable k‒ε turbulent model. The variable baffle parameters considered first in the current simulation were the relative height/blockade ratio (B<inf>R</inf> = 0.05−0.2) and the flap angle of the baffle hole (β = 0° − 90°), while the fixed parameters included the attack angle (α = 60°), hole diameter ratio (d<inf>R</inf> = 0.5), and pitch ratio (P<inf>R</inf> = 0.5). To accomplish this goal, the previously mentioned parameters providing the best thermal performance were investigated further by extending the values of B<inf>R</inf> to 0.25−0.3, d<inf>R</inf> to 0.8 and α to 45°−30°. The simulation results indicate that the jet flowing from the flapped hole, as well as the vortices created by the baffle, can boost heat transfer and friction loss in comparison to the plain duct. In comparison, using a flapped baffle with β > 0° results in less friction loss, a greater thermal enhancement factor (TEF), and a higher Nusselt number than using a baffle with no flap. The first investigation disclosed that for B<inf>R</inf> = 0.2 and β = 20°, the greatest TEF of 2.19 with Nu/Nu<inf>0</inf> of 7.9 times are obtained. The extended study, on the other hand, showed that the highest TEF of roughly 2.49 with Nu/Nu<inf>0</inf> of 8.4 times are seen for α = 45°, d<inf>R</inf> = 0.8, B<inf>R</inf> = 0.25 and β = 20° at lowest Re. Thus, the flapped baffle provides a significant increase in Nu/Nu<inf>0</inf> and TEF over the baffle alone.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Thermal characterization in a circular tube fitted with inclined horseshoe baffles
    (2015-01-22) ;
    Tamna, Sombat
    ;
    ;
    In the present study, the influence of inclined horseshoes baffles placed repeatedly in a tubular heat exchanger on heat transfer rate, friction factor and thermal enhancement factor are experimentally determined. The horseshoe baffle elements with an inclination angle of 20° were inserted periodically into the test tube at three different baffle-pitch ratios (P<inf>R</inf> = 0.5, 1.0 and 2) and -width or blockage ratios (B<inf>R</inf> = 0.1, 0.15 and 0.2). The experiment was conducted in the test tube having a uniform heat-fluxed wall by varying turbulent airflow to obtain Reynolds number in a range of 5300-24,000. The experimental results revealed that the tube fitted with inclined horseshoes baffles provides considerable improvement of the heat transfer rate over the plain tube around 92-208% while the friction factor is increased at about 1.76-6.37 times. To access the real benefits for the inclined horseshoes baffles inserted in plain tube, thermal performance factor is examined and found to be in the range of 1.34-1.92 at which the maximum obtained at P<inf>R</inf> = 0.5 and B<inf>R</inf> = 0.1 is considerably higher than that for published inserted devices. Correlations for Nusselt number and friction factor for the oblique horseshoe-baffled tube are also proposed.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Heat transfer improvement in a square duct with diagonal inclined ribs
    (2014-01-01)
    Suwannapan, Supattarachai
    ;
    Poomsalood, Ratsak
    ;
    ; ;
    Limkul, Thitipat
    This research presents a numerical study of turbulent periodic flow and heat transfer in three-dimensional isothermal-fluxed square duct with diagonal inclined rib inserted. The fluid flow and heat transfer characteristics are presented for Reynolds numbers in the range of 4000 to 20,000. The computations based on the finite volume method, and the SIMPLE algorithm has been implemented. Effects of rib pitch ratios (0.5 to 2) at a single blockage ratio of 0.2 and attack angle of 60° on heat transfer and friction factor in the duct are examined and their results of the inclined rib are also compared with those of the smooth duct. It is found that the inclined rib provides higher heat transfer rate and friction factor than the smooth duct for all cases. In addition, the decreasing of the pitch ratio leads to the rise in the Nusselt number and friction factor. © (2014) Trans Tech Publications, Switzerland.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Turbulent flow heat transfer and pressure loss in a double pipe heat exchanger with louvered strip inserts
    (2008-02-01)
    Eiamsa-ard, Smith
    ;
    Pethkool, Somsak
    ;
    ;
    In the present work, heat transfer and friction characteristics were experimentally investigated, employing louvered strips inserted in a concentric tube heat exchanger. The louvered strip was inserted into the tube to generate turbulent flow which helped to increase the heat transfer rate of the tube. The flow rate of the tube was in a range of Reynolds number between 6000 and 42,000. The turbulent flow devices were consisted of (1) the louvered strips with forward or backward arrangements, and (2) the louvered strip with various inclined angles (θ = 15°, 25° and 30°), inserted in the inner tube of the heat exchanger. In the experiment, hot water was flowed through the inner tube whereas cold water was flowed in the annulus. The experimental data obtained were compared with those from plain tubes of published data. Experimental results confirmed that the use of louvered strips leads to a higher heat transfer rate over the plain tube. The increases in average Nusselt number and friction loss for the inclined forward louvered strip were 284% and 413% while those for the backward louvered strip were 263% and 233% over the plain tube, respectively. In addition, the use of the louvered strip with backward arrangement leads to better overall enhancement ratio than that with forward arrangement around 9% to 24%. © 2007 Elsevier Ltd. All rights reserved.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Thermal characteristics in round tube fitted with serrated twisted tape
    (2010-09-01)
    Eiamsa-Ard, Smith
    ;
    The article presents an investigation of the effect of twisted tape with serrated-edge insert on heat transfer and pressure loss behaviors in a constant heat-fluxed tube. In the experiments, the serrated twisted tape (STT) was inserted into the entire test tube with a constant twist ratio in order to generate a continuous swirling airflow. Two geometry parameters of the STT to be considered in the present work are the serration width ratio and the serration depth ratio. The measurements have been conducted for the airflow rate based on Reynolds numbers in the turbulent regime from 4000 to 20,000. The experimental results of the STT inserted tube are compared with those of the plain tube fitted with typical twisted tape (TT). The results show that the heat transfer rate in terms of Nusselt number, Nu increases with the rise in the depth ratio but decreases with raising the width ratio. The heat transfer rate is up to 72.2% and 27% relative to the plain tube and the TT inserted tube, respectively. The use of the STT leads to higher heat transfer rate and friction factor than that of the TT for all cases. The thermal performance factor of the STT tube under constant pumping power is evaluated and found to be above unity indicating that using the STT tube is advantageous over the TT tube or the plain tube. In addition, the empirical correlations developed by relating the serration width ratio, serration depth ratio and Reynolds number are determined. © 2010 Elsevier Ltd. All rights reserved.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Thermal characteristics in square channel with 45° staggered baffle inserts
    (2010-12-06) ;
    Skullong, Sompot
    ;
    Teschareon, Thavee
    ;
    The paper presents a study of heat transfer in a heat exchanger channel inserted with staggered inclined baffles. The channel has a square section with uniform wall heat flux conditions. The fluid flow and heat transfer characteristics are presented for Reynolds numbers based on the hydraulic diameter of the channel ranging from 4000 to 25,000. The inclined baffles with an axial pitch equal to three times of channel height and with the attack angle of 45° are mounted in tandem and staggered arrangement on the lower and upper walls of the test channel. Effects of four baffle-to-channel height ratios (e/H = 0.1, 0.2, 0.3 and 0.4) on heat transfer in terms of Nusselt number and pressure loss in the form of friction factor are experimentally investigated. The experimental result shows that the insertion of staggered inclined baffles with the e/H=0.4 provides higher heat transfer and friction factor values than others. This is caused by higher baffle-to-channel height ratios of using e/H = 0.4 interrupting the flow and diverting its direction thus promoting high levels of mixing over others.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Turbulent heat transfer enhancement in a heat exchanger using helically corrugated tube
    (2011-03-01)
    Pethkool, S.
    ;
    Eiamsa-ard, S.
    ;
    ;
    The augmentation of convective heat transfer in a single-phase turbulent flow by using helically corrugated tubes has been experimentally investigated. Effects of pitch-to-diameter ratio (P/D<inf>H</inf>=0.18, 0.22 and 0.27) and rib-height to diameter ratio (e/D<inf>H</inf>=0.02, 0.04 and 0.06) of helically corrugated tubes on the heat transfer enhancement, isothermal friction and thermal performance factor in a concentric tube heat exchanger are examined. The experiments were conducted over a wide range of turbulent fluid flow of Reynolds number from 5500 to 60,000 by employing water as the test fluid. Experimental results show that the heat transfer and thermal performance of the corrugated tube are considerably increased compared to those of the smooth tube. The mean increase in heat transfer rate is between 123% and 232% at the test range, depending on the rib height/pitch ratios and Reynolds number while the maximum thermal performance is found to be about 2.3 for using the corrugated tube with P/D<inf>H</inf>=0.27 and e/D<inf>H</inf>=0.06 at low Reynolds number. Also, the pressure loss result reveals that the average friction factor of the corrugated tube is in a range between 1.46 and 1.93 times over the smooth tube. In addition, correlations of the Nusselt number, friction factor and thermal performance factor in terms of pitch ratio (P/D<inf>H</inf>), rib-height ratio (e/D<inf>H</inf>), Reynolds number (Re), and Prandtl number (Pr) for the corrugated tube are determined, based on the curve fitting of the experimental data. © 2010 Elsevier Ltd.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Heat transfer augmentation in a helical-ribbed tube with double twisted tape inserts
    (2012-08-01) ;
    Pethkool, Somsak
    ;
    ;
    Turbulent convective heat transfer characteristics in a helical-ribbed tube fitted with twin twisted tapes have been investigated experimentally. The experiment was carried out in a double tube heat exchanger using the helical-ribbed tube having a single rib-height to tube-diameter ratio, e/D <inf>H</inf>=0.06 and rib-pitch to diameter ratio, P/D <inf>H</inf>=0.27 as the tested section. The insertion of the double twisted tapes with twist ratio, Y, in the range of 2.17 to 9.39 is to create vortex flows inside the tube. The inserted ribbed tube is arranged in similar directions of the helical swirl of the twisted tape and the helical rib motion of the tube (called co-swirl). Effects of the co-swirl motion of the ribbed tube and the double twisted tapes with various twist ratios on heat transfer and friction characteristics are examined. The results obtained from the ribbed tube and the twin twisted tape insert are compared with those from the smooth tube and the ribbed tube acting alone. The experimental results reveal that the co-swirling inserted tube performs much better than the ribbed/smooth tube alone at a similar operating condition. The co-swirl tube at Y≈8 yields the highest thermal performance at lower Reynolds number (Re). In addition, the correlations of Nusselt number and friction factor as functions of Re, Pr and Y are also proposed. © 2012 Elsevier Ltd.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Thermal characteristics in a heat exchanger tube fitted with dual twisted tape elements in tandem
    (2010-01-01)
    Eiamsa-ard, Smith
    ;
    ;
    Eiamsa-ard, Petpices
    ;
    The paper presents a comparative investigation of enhanced heat transfer and pressure loss by insertion of single twisted tape, full-length dual and regularly-spaced dual twisted tapes as swirl generators, in a round tube under axially uniform wall heat flux (UHF) conditions. The investigation encompassed the Reynolds number based on the inlet tube diameter (D) ranging from 4000 to 19,000. The experiments are performed using single twisted tapes and full-length dual twisted tapes with three different twist ratios (y/w = 3.0, 4.0 and 5.0) and also regularly-spaced dual twisted tapes with three different space ratios (s/D = 0.75, 1.5 and 2.25). The effects of major parameters on heat transfer and friction factor are discussed and the results from both single and dual twisted tape inserts are compared with those from the plain tube. The result shows that the heat transfer of the tube with dual twisted tapes is higher than that of the plain tube with/without single twisted tape insert. For both single twisted tape and full-length dual twisted tapes, Nusselt number (Nu) and friction factor (f) tend to increase with decreasing twist ratio (y/w). The average Nusselt number and friction factor in the tube fitted with the full-length dual twisted tapes at y/w = 3.0, 4.0 and 5.0, are respectively 146%, 135% and 128%; and 2.56, 2.17 and 1.95 times of those in the plain tube. For the regularly-spaced dual twisted tapes, the heat transfer rate is decreased with increasing space ratio (s/D). The average Nusselt numbers in the tube fitted with the regularly-spaced dual twisted tapes (s/D) of 0.75, 1.5 and 2.25 are respectively, 140%, 137% and 133% of that in the plain tube. With the similar trend mentioned above, all dual twisted tapes with free spacing yield lower heat transfer enhancement in comparison with the full-length dual twisted tapes (s/D = 0.0). © 2009 Elsevier Ltd. All rights reserved.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Heat transfer augmentation in a round tube with 60° winglet pair inserts
    (2014-01-01)
    Chokphoemphun, Suriya
    ;
    Tongyote, Pattarapan
    ;
    ; ;
    Chompookham, Teerapat
    The experimental study on heat transfer enhancement in a tubular heat exchanger fitted with 60o winglet pairs is carried out by varying airflow velocity in turbulent region in the test section having a constant wall heat-flux. Effects of three blockage ratios (BR=e/D= 0.1, 0.15 and 0.2) and three pitch ratios (PR=P/D= 1, 1.5 and 2) of the winglet pairs on heat transfer rates in the terms of Nusselt number (Nu) and pressure loss in the form of friction factor (f) are examined. The experimental results illustrated that the tube with winglet pair insert provides the heat transfer rate higher than the smooth tube around 1.7 to 2.6 times, depending upon operating conditions. The thermal enhancement factor for using the winglet-pair turbulator is in a range of 1.03 - 1.31. © (2014) Trans Tech Publications, Switzerland.