Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Enhanced heat transfer performance in channel with delta-wing perforated V-type baffles
Loading...
Thumbnail Image

Enhanced heat transfer performance in channel with delta-wing perforated V-type baffles

Author(s)
Eiamsa-ard, Smith
Phila, Arnut
Thianpong, Chinaruk
Chuwattanakul, Varesa
Maruyama, Naoki
Hirota, Masafumi
Date Issued
October 1, 2023
Type
Article
DOI
10.1007/s10973-023-12452-2
Abstract
The article examines the influence of delta-wing V-type baffles (DW-PVBs) on the average Nusselt number, local Nusselt number distribution, pressure losses, and thermal performance behaviors in a channel. Delta-wing perforated V-type baffles (DW-PVBs) mounted in a regular manner on the bottom of a channel produced two pairs of longitudinal counter-rotating vortices to enhance chaotic fluid mixing and destabilize the boundary layer, hence boosting the heat transfer. The geometric characteristics of the delta-wing V-type baffle (DW-PVBs) located on the bottom of the channel were examined at relative baffle blockage and pitch ratios (BR = h/H = 0.3 and p/H = 1.5), and five delta-wing attack angles, θ = 0o (solid V-shaped baffle), 22.5°, 45°, 67.5°, and 90°. The present DW-PVBs mounted on the channel were designed to mitigate pressure loss due to flow blockage. The experiment was done by permitting air to flow through a channel at Reynolds numbers (Re) ranging from 6000 to 24,000. The present results show that the friction factor using the DW-PVBs decreased considerably with increasing θ values. The experimental results revealed that small θ values yielded greater heat transfer and resistance than large θ values. The DW-PVBs with θ = 22.5° performed better than inserts with other θ values in terms of heat transfer rate. It was also observed that the DW-PVBs with θ = 45° gave the maximum thermal performance factor (TPF), while presenting a 13.64–17.26% lower friction factor than the solid V-shaped baffle. Furthermore, it was also found that the DW-PVBs with θ = 0°, 22.5°, 45°, 67.5°, and 90° gave peak TPF values of up to 1.87, 1.89, 1.91, 1.87, and 1.84 at the lowest Reynolds number, 6000.
Citation
Journal of Thermal Analysis and Calorimetry, 148(20), 11283-11301, 2023
Subjects

Delta-wing

Heat transfer

Heat transfer enhance...

Turbulent flow

V-type baffle

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback