Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Personal identification using a delaunay triangle and optic disc retinal vascular pattern
Loading...
Thumbnail Image

Personal identification using a delaunay triangle and optic disc retinal vascular pattern

Author(s)
Kanjanasurat, Isoon
Purahong, Boonchana
Aoyama, Hisayuki
Benjangkaprasert, Chawalit
Pintavirooj, Chuchart
Date Issued
January 1, 2020
Type
Article
DOI
10.24507/ijicic.16.03.879
Abstract
Retinal vascular patterns are unique and individual. They provide highly secure and correct identity authentication. In this study, we exploit an image alignment approach based on a geometric invariant, which is the area spanned by feature-point triplets for personal identification. First, we located the optic disc by using a projection of the vascular structure in vascular extraction and extracted feature points that are bifurca- tions of a retinal blood vessel in the vicinity of the optic disc as the landmarks. Delaunay triangulation is then applied to the extracted feature points. The absolute invariant is then derived by taking the ratio of successive triangular area patches. The alignment is achieved by establishing correspondences between feature points after a conformal sort- ing step based on a derived set of absolute affine invariants. The affine transformation parameters can then be calculated by the corresponding vertices of the most robust neigh- bouring triangle of both inquiry and reference images. The optic disc localization results successfully located 95.95% in six widely used retinal image databases. The algorithm of vascular extraction, applied on the DRIVE database, provided an average accuracy of ap- proximately 94.1%. The best accuracy and sensitivity for neighbouring triangle matching obtained were 99.90% and 87.66%, respectively.
Citation
International Journal of Innovative Computing Information and Control, 16(3), 879-897, 2020
Subjects

Delaunay triangle

Neighbour area ratio

Optic disc localizati...

Retinal identificatio...

Vessel extraction

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback