  4. A Study on Transparent Type Envelope Material in Terms of Overall Thermal Transfer, Energy, and Economy for an Office Building Based on the Thai Building Energy Code
Loading...
Thumbnail Image

A Study on Transparent Type Envelope Material in Terms of Overall Thermal Transfer, Energy, and Economy for an Office Building Based on the Thai Building Energy Code

Author(s)
Chiradeja, Pathomthat
Thongsuk, Surakit
Ananwattanaporn, Santipont
Ngaopitakkul, Atthapol
Yoomak, Suntiti
Date Issued
July 1, 2023
Type
Article
DOI
10.3390/su151310435
Abstract
Energy consumption in buildings has increased significantly as population and economic activities are concentrated in urban areas. Air conditioning accounts for a significant percentage of energy consumption in buildings, especially in tropical climates. The main area where heat can be transferred into the building is through glass windows. Thus, this study aims to evaluate feasibility in terms of overall thermal transfer value (OTTV), energy, and economics for retrofitting different glass materials in an office building in Thailand by using building energy code (BEC) software. The software uses Thailand’s building energy code as the standard to evaluate the energy performance of the case study building in comparison with different glass types used in retrofitted cases. From an economic perspective, the internal rate of return (IRR) and discounted payback periods (DPP) were used as determining indexes. The results demonstrated that retrofitted windows with the best energy-efficient glass might achieve energy performance, but installation cost can reduce economic feasibility, while the glass with the second lowest heat transfer coefficient can reduce the OTTV by 68.89% and building energy consumption by 16.87%. However, it can achieve the highest economic performance with 10.70% IRR and DPP at 11.83 years. Therefore, the balance between energy and economic factors must be considered to provide energy-efficient and investment-friendly glass materials for retrofit projects. In addition, the study focuses specifically on tropical climates. Thus, the finding may not be reflected similarly for buildings located in different regions.
Citation
Sustainability Switzerland, 15(13), 2023
Subjects

economic analysis

glass material

overall thermal trans...

thermal characteristi...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback