Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Enhanced Heat Transfer of a Heat Exchanger Tube Installed with V-Shaped Delta-Wing Baffle Turbulators
Loading...
Thumbnail Image

Enhanced Heat Transfer of a Heat Exchanger Tube Installed with V-Shaped Delta-Wing Baffle Turbulators

Author(s)
Samruaisin, Prachya
Maza, Rangsan
Thianpong, Chinaruk
Chuwattanakul, Varesa
Maruyama, Naoki
Hirota, Masafumi
Eiamsa-ard, Smith
Date Issued
July 1, 2023
Type
Article
DOI
10.3390/en16135237
Abstract
The influences of V-shaped delta-wing baffles on the thermohydraulic performance characteristics in a round tube were experimentally tested. The V-shaped delta-wing baffles having a set number of wings (N = 4, 6, and 8) were comparatively tested. The V-shaped delta-wing baffles with various pitch ratios of P/D = 2.0, 2.5, and 3.0 were thoroughly fitted inside a tube. In the present work, the baffles were responsible for both the recirculation/reverse flow behind the solid baffle and the longitudinal vortex flow behind the V-shaped wing. The V-shaped winged baffles with N = 8 produced high heat transfer rates by promoting the development of reverse and vortex flows. These currents aid in fluid mixing between the two streams. Experimental results suggested that utilizing V-shaped delta-wing baffles having N = 4, 6, and 8 led to Nusselt number enhancement of up to 97–105.6%, 105.8–127.8% and 114.8–138.9%, respectively. When N was 8, the V-shaped wings baffles created additional multi vortex flows, which resulted in some fluid mixing between the vortex and the reverse flow. It was discovered that a greater turbulent intensity is imparted to the flow that was occurring between the V-shaped delta-wing baffles, which led to an increase in the rate of heat transfer when the pitch ratio was decreased. The increase in Nusselt number was up to 118.26–151.3% more than it was in a tube with the lowest pitch ratio (P/D = 2.0). It was also found that the baffles with N = 8 wings and P/D = 3.0 offered a maximum aerothermal performance factor (APF) of 1.01. Furthermore, the V-shaped delta-wing baffles have the potential for energy savings at low Re ≤ 6000, indicated by the APF beyond unity.
Citation
Energies, 16(13), 2023
Subjects

aerothermal performan...

heat transfer

turbulator

V-shaped winged-baffl...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback