Ananwattanaporn, Santipont
Loading...
Preferred name
Ananwattanaporn, Santipont
Alternative Name
Ananwattanaporn, S.
Ananwattananporn, Santipont
Main Affiliation
Email
santipont.an@kmitl.ac.th
21 results
Now showing 1 - 10 of 21
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Design and application of daylight-based lighting controller on LED luminaire(2020-05-01) ;Bunjongjit, Sulee; ; ; Patcharoen, TheerasakThis paper proposes a control circuit for Light Emitting Diode (LED) luminaire based on the amount of daylight. This system uses both natural daylight and artificial light from a luminaire to reach the desired illuminance on a working plane. The control circuit operates by receiving an illuminance value from a light sensor and comparing it with a set value in the microcontroller before limiting the light intensity of LED by sending a control Pulse Width Modulation (PWM) signal to the LED driver. In the experimental setup, the controller and a physical model of a working space were built in order to field test the LED daylight control circuit. Electrical characteristics such as voltage, current, and power were measured with a power meter. Illumination characteristics in terms of illuminance on a working plane were determined using a lux meter. The results from actual field tests revealed that this LED control circuit was able to reduce the power consumption of the lighting system while keeping the illuminance on the working plane at the standard value. Both simulation results and the actual experiment of the control circuit proved that it could be used to improve the energy efficiency of both newly installed and retrofitted lighting systems. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Development and Analysis of a Fast-Charge EV-Charging Station Model for Power Quality Assessment in Distribution Systems(2025-09-01) ;Chiradeja, Pathomthat; ;Srisuksai, Panu ;Klomjit, JittiphongWith the rapid rise in electric vehicle (EV) adoption, the deployment of EV charging infrastructure—particularly fast-charging stations—has expanded significantly to meet growing energy demands. While fast charging offers the advantage of reduced charging time and improved user convenience, it imposes considerable stress on existing power distribution systems due to its high power and current requirements. This study investigated the impact of EV fast charging on power quality within Thailand’s distribution network, emphasizing compliance with accepted standards such as IEEE Std 519-2014. We developed a control-oriented EV-charging station model in power systems computer-aided design and electromagnetic transients, including DC (PSCAD/EMTDC), which integrates grid-side vector control with DC fast-charging (CC/CV) behavior. Active/reactive power setpoints were mapped onto (Formula presented.) current references via Park’s transformation and regulated by proportional integral (PI) controllers with sinusoidal pulse-width modulation (SPWM) to command the voltage source converter (VSC) switches. The model enabled dynamic studies across battery state-of-charge and staggered charging schedules while monitoring voltage, current, and total harmonic distortion (THD) at both transformer sides, charger AC terminals, and DC adapters. Across all scenarios, the developed control achieved grid-current THDi of <5% and voltage THD of <1.5%, thereby meeting IEEE 519-2014 limits. These quantitative results show that the proposed, implementation-ready approach maintains acceptable power quality under diverse fast-charging patterns and provides actionable guidance for planning and scaling EV fast-charging infrastructure in Thailand’s urban networks. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Comparative Fault Detection Between DWT and STFT in Overcurrent Relays(2024-01-01) ;Chiradeja, Pathomthat; ;Lertwanitrot, Praikanok; This study proposes a protection relay using a microcontroller to detect and classify faults in transmission lines based on the Wavelet transform. An experimental model was constructed from an actual 115 kV transmission system prototype. The current signal was observed based on the fault type, phase, and position. Clark's transform and the discrete Wavelet transform (DWT) were applied to transform signals for analysis. The positive and zero sequences obtained from Clark's transform were used for fault detection and fault classification, respectively. Moreover, the performances between the DWT and the short-time Fourier Transform (STFT) were compared in terms of accuracy and processing time. In addition, the double-detection technique was used to confirm the accuracy of fault detection. Results show that the proposed method is efficient for fault detection and classification. This finding allows the researcher to choose the appropriate analytical method. Moreover, it can also be used as the basis for overcurrent relay algorithm design in the effort to develop more advanced technologies. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Analysis of Investment Feasibility for EV Charging Stations in Residential Buildings(2025-09-01) ;Chiradeja, Pathomthat; ;Sottiyaphai, Chayanut; Klomjit, JittiphongThis study investigates the financial and operational feasibility of deploying electric vehicle (EV) charging infrastructure within high-density residential buildings, utilizing empirical operational data combined with comprehensive financial modeling. A 14-day monitoring period conducted at a residential complex comprising 958 units revealed distinct charging behaviors, with demand peaking during weekday evenings between 19:00 and 22:00 and displaying more dispersed yet lower overall utilization during weekends. Energy efficiency emerged as a significant operational constraint, as standby power consumption contributed substantially to total energy losses. Specifically, while total energy consumption reached 248.342 kW, only 138.24 kW were directly delivered to users, underscoring the necessity for energy-efficient hardware and intelligent load management systems to minimize idle consumption. The financial analysis identified pricing as the most critical determinant of project viability. Under current cost structures, financial break-even was attainable only at a profit margin of 0.2286 USD (8 THB) per kWh, while lower margins resulted in persistent financial deficits. Sensitivity analysis further demonstrated the considerable vulnerability of the project’s financial performance to small fluctuations in profit share and utilization rate. A 10% reduction in either parameter entirely eliminated the project’s ability to reach payback, while variations in energy costs, capital expenditures (CAPEX), and operational expenditures (OPEX) exerted comparatively limited influence. These findings emphasize the importance of precise demand forecasting, adaptive pricing strategies, and proactive government intervention to mitigate financial risks associated with residential EV charging deployment. Policy measures such as capital subsidies, technical regulations, and transparent pricing frameworks are essential to incentivize private sector investment and support sustainable expansion of EV infrastructure in residential sectors. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Transient Analysis to Distinguish Mechanically Switched Capacitors Using Discrete Wavelet Transform and Artificial Intelligence(2026-01-01) ;Thongsuk, Surakit ;Bunjongjit, Sulee; ; Capacitor banks are widely used in modern power systems for reactive power compensation and voltage regulation. However, switching operations of mechanically switched capacitors (MSCs) can generate transient phenomena, such as inrush currents, which may resemble fault currents and lead to misoperation of protection systems. Therefore, accurate detection and classification of transient events are essential for reliable system operation. This study proposes a hybrid approach for transient signal analysis and classification by integrating the discrete wavelet transform (DWT) with artificial intelligence (AI) techniques, including probabilistic neural networks and fuzzy inference systems (FIS). The DWT performs time–frequency analysis to extract multi-scale wavelet features from three-phase current signals. The proposed method enables both discrimination between inrush and fault currents and multi-class classification of transient events among six capacitor switching conditions, namely base case, pre-insertion resistor, pre-insertion inductor, current limiting reactor, 6% reactor, and synchronous closing. The methodology is validated using PSCAD/EMTDC simulations under isolated and back-to-back capacitor switching scenarios. The results demonstrate that the proposed DWT–AI approach achieves high classification accuracy exceeding 95%, outperforming conventional methods based on DWT alone and DWT combined with FIS. Furthermore, the proposed method improves protection system performance by reducing false tripping caused by transient inrush currents, while maintaining reliable fault detection capability. The findings confirm that integrating time–frequency signal processing with AI-based classification provides an effective and practical solution for transient event discrimination in MSC capacitor bank systems. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, The Design and Evaluation of Nanogrid-Based Solar Photovoltaic Light-Emitting Diode Street Lighting Systems: A Techno-Economic and Voltage Drop Analysis for Secondary Roads in Thailand(2026-05-01) ;Bunjongjit, Sulee ;Wang, Hongyan ;Huang, Yansheng ;Songsukthawan, PanapongStreet lighting systems are essential for ensuring nighttime road safety and visibility. The integration of solar photovoltaic (PV) systems into street lighting infrastructure improves energy efficiency and sustainability; however, the mismatch between daytime energy generation and nighttime lighting demand requires effective energy management solutions. In addition, long-distance electrical connections introduce voltage drop constraints, which are often overlooked in conventional design approaches. This study addresses the integration of lighting design, electrical constraints, and techno-economic performance in nanogrid-based LED street lighting systems for secondary roads. A unified framework is developed to evaluate lighting performance, PV–battery sizing, voltage drop behavior, and lifecycle cost under different system architectures. Optimal pole spacing and luminaire ratings are determined using DIALux, while PV–battery configurations are optimized using HOMER Pro based on site-specific solar irradiance. The analysis focuses on voltage drop as the key electrical constraint and examines its impact under decentralized and centralized nanogrid configurations (25%, 50%, and 100%) in both stand-alone and grid-connected modes. The results show that increasing centralization reduces component redundancy but significantly increases cable length, conductor sizing, and infrastructure cost. A techno-economic assessment with lifecycle cost and sensitivity analysis indicates that a 25% centralized configuration reduces total system cost by approximately 23% compared to fully decentralized systems while avoiding excessive cabling costs. These findings demonstrate that voltage drop and electrical infrastructure constraints play a decisive role in determining optimal system design, highlighting the importance of system-level integration rather than isolated optimization of lighting or energy components. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Power Quality Improvement Based on Active Harmonic Filter in 24 kV Liquefied Natural Gas Industrial Plant’s Photovoltaic System(2026-06-01); ;Patcharoen, Theerasak ;Lothongkam, Chaiyaporn; Lertwanitrot, PraikanokThis paper presents a case study demonstrating the power quality improvements in a 24 kV distribution system at a liquefied natural gas (LNG) industrial plant with variable speed drives (VSDs), the conventional capacitor bank, and a rooftop solar photovoltaic system. Solar photovoltaic (PV) inverters can supply harmonic currents to the grid, potentially affecting the system and causing maloperation of sensitive equipment in both the utility systems and neighboring industries connected to it. Therefore, the installation of shunt active power filters (APFs) in a 400 V system was proposed in this study. The installed locations were varied, and the corresponding power qualities were analyzed. The results were examined in terms of design and harmonic elimination. Simulations were conducted using the PSCAD/EMTDC software version 4.5. The power quality simulation and field measurement results after the APF installation were compared to demonstrate the effectiveness of the proposed solutions. The addition of APFs was found to improve the power quality. In addition to the mechanism analysis, the economic feasibility of the proposed approach was investigated. The costs of APF installation in various locations were analyzed. The results show that the proposed method can improve the power supply at a reasonable price. This work contributes to sustainable industrial energy systems by improving the reliability and power quality of photovoltaic-integrated electrical networks, thereby supporting higher penetration of renewable energy resources and stable low-carbon industrial operation. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Financial feasibility of electric vehicle charging stations in Thailand: An analysis of operational models and energy costs(2025-07-01) ;Chiradeja, Pathomthat ;Sottiyaphai, Chayanut; Despite the increasing demand for electric vehicles (EVs) and the associated charging stations, the variances in EV charging station models and diversity of energy costs have not been effectively studied to date. Therefore, this study examines the financial viability of EV charging stations in Thailand by analysing the effects of operational models, charger counts, and fluctuating energy costs. The profitability, payback periods, and investment returns of various types of EV charging stations are evaluated by combining financial analysis tools and historical energy cost data. The results indicate that small-scale charging stations with 1–3 chargers demonstrate superior financial viability, achieving internal rates of return (IRR) of 24.18–39.86 % and payback periods ranging from 3 to 4 years, depending on the tariff model. By contrast, stations with more than three chargers experience extended payback periods, with some configurations failing to recover investment within the project duration owing to increased capital expenditures and operational costs. This study also emphasises the critical role of dynamic energy pricing in the financial modelling of charging stations. Electricity costs vary significantly between conventional and low-priority stations, with energy costs for conventional stations being up to 23 % higher. The financial feasibility of EV charging stations in Thailand presents competitive advantages in terms of investment attractiveness and return on capital compared with higher energy cost regions with fewer financial incentives. The findings have significant implications for station operators, investors, and policymakers, highlighting the need for strategic planning and adaptive pricing strategies in EV charging infrastructure development. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, An approach to energy conservation in lighting systems using luminaire-based sensor for automatic dimming(2025-12-01); ;Thongsuk, Surakit ;Sottiyaphai, Chayanut ;Songsukthawan, PanapongChiradeja, PathomthatLighting systems account for a significant proportion of energy consumption in buildings. Therefore, energy conservation within these systems can greatly enhance overall building energy efficiency. This study proposes a control strategy for LED lamps by adjusting lighting intensity and improving the performance of electric luminaires. The approach involves implementing an automated dimming system that adapts lighting intensity based on surrounding light levels. A system comprising an ambient light sensor, microcontroller, power supply module, dimming controller, and lamp was developed. The sensors measure brightness within a specified range in real time, and the microcontroller analyzes and compares this data against the brightness settings for specific areas. The designed control system was tested in a laboratory setup to demonstrate its effectiveness in a controlled environment. Results showed a 75.65% reduction in power consumption compared to standard lamps in a simulated environment, highlighting its potential for significant energy savings in buildings and its contribution to environmental sustainability. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Evaluating Effects of Electric Vehicle Chargers on Residential Power Infrastructure(2025-06-01) ;Chiradeja, Pathomthat ;Chuadmee, Orawan; ;Sottiyaphai, ChayanutThis study investigated the impact of electric vehicle (EV) chargers on residential electrical systems through a real-world case study in a condominium located in Bangkok, Thailand. A two-week field measurement was conducted to analyze load profiles, current and voltage behavior, phase symmetry, and harmonic distortion during EV charger operation. The results show that single-phase charging dominated usage patterns, leading to phase imbalance and significant neutral current flow. Voltage unbalance was quantified using the maximum deviation method, with an average value of 0.535 percent and a peak of 2.18 percent observed during charging activity. A harmonic distortion analysis revealed a substantial increase in current total harmonic distortion (THD) during active charging, with values rising to between 15 and 20 percent. These findings highlight nonlinear loading effects that may reduce power quality and pose risks to electrical equipment and system stability. In retrofitted electrical infrastructures, these effects are often exacerbated by design limitations and the absence of coordinated load management. This study’s findings offer practical insights for engineers, facility managers, and policymakers in designing EV-ready residential systems that are both efficient and resilient.