Thianpong, Chinaruk
Loading...
Preferred name
Thianpong, Chinaruk
Alternative Name
Thianpong, C.
Main Affiliation
Email
chinaruk.th@kmitl.ac.th
6 results
Now showing 1 - 6 of 6
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Numerical heat transfer study of square duct equipped with novel flapped V-baffles(2024-03-01); ; ;Skullong, Sompol ;Promthaisong, PitakNakhchi, Mahdi ErfanianThe paper describes a computational study of heat transfer enhancement inside a square duct with V-shaped flapped baffles located repeatedly on the bottom and top walls for fluid flowing with Reynolds numbers (Re) from 3000 to 21,000. The basic goal of this work is to attain the largest relative Nusselt number (Nu/Nu<inf>0</inf>) whilst maintaining the highest thermal performance to improve energy savings. A finite volume method was used in the computations, along with the Realizable k‒ε turbulent model. The variable baffle parameters considered first in the current simulation were the relative height/blockade ratio (B<inf>R</inf> = 0.05−0.2) and the flap angle of the baffle hole (β = 0° − 90°), while the fixed parameters included the attack angle (α = 60°), hole diameter ratio (d<inf>R</inf> = 0.5), and pitch ratio (P<inf>R</inf> = 0.5). To accomplish this goal, the previously mentioned parameters providing the best thermal performance were investigated further by extending the values of B<inf>R</inf> to 0.25−0.3, d<inf>R</inf> to 0.8 and α to 45°−30°. The simulation results indicate that the jet flowing from the flapped hole, as well as the vortices created by the baffle, can boost heat transfer and friction loss in comparison to the plain duct. In comparison, using a flapped baffle with β > 0° results in less friction loss, a greater thermal enhancement factor (TEF), and a higher Nusselt number than using a baffle with no flap. The first investigation disclosed that for B<inf>R</inf> = 0.2 and β = 20°, the greatest TEF of 2.19 with Nu/Nu<inf>0</inf> of 7.9 times are obtained. The extended study, on the other hand, showed that the highest TEF of roughly 2.49 with Nu/Nu<inf>0</inf> of 8.4 times are seen for α = 45°, d<inf>R</inf> = 0.8, B<inf>R</inf> = 0.25 and β = 20° at lowest Re. Thus, the flapped baffle provides a significant increase in Nu/Nu<inf>0</inf> and TEF over the baffle alone. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Heat transfer performance evaluation of a solar air heater duct with multiple tapered V-baffles(2025-12-01); ;Kaewkosum, P. ;Woncharee, K. ;Keaitnukul, W.Maruyama, N.This report aims to study the heat transfer enhancement, pressure loss characteristics, and thermal performance of a channel equipped with multiple tapered V-shaped baffles (MTVBs). The effects of up-facing and down-facing orientations, converging (C) and diverging(D) configurations, variations in the taper ratio (e<inf>CR</inf> and e<inf>DR</inf> = 0.0 and 0.5), and Reynolds number (6000 ≤ Re ≤ 24,000) are examined. The performance of UF-C-MTVBs, DF-C-MTVBs, UF-D-MTVBs, and DF-D-MTVBs is analyzed and compared with that of the conventional transverse baffles (TBs) and MVBs (e<inf>DR</inf> = 1.0). The experimental setup maintained a constant attack angle (α) of 45°, pitch ratio (p/H) of 1.5, width-shaped ratio (W<inf>b</inf>/W) of 0.25, and blockage ratio (e/H) of 0.3. Tests were conducted at a fixed Prandtl number of 0.71, and a thermochromic liquid crystal sheet was utilized to assess the local Nusselt number distribution on the wall installed with UF-C-MTVBs, DF-C-MTVBs, UF-D-MTVBs, and DF-D-MTVBs. The results reveal that the channel with MVBs (e<inf>DR</inf> = 1.0) achieves the greatest heat transfer rate, with a Nu/Nu<inf>s</inf> ratio of up to 4.37 while a f/f<inf>s</inf> ratio reaching 48.12. In contrast, D-MTVBs at e<inf>DR</inf> = 0.0, despite having a lower Nu/Nu<inf>s</inf> ratio (maximum 3.87), attain the maximum thermal performance of 1.39 at Re = 6000, owing to their optimized design that effectively enhances heat transfer while minimizing pressure drop. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Effect of louvered curved-baffles on thermohydraulic performance in heat exchanger tube(2023-02-01); ; ; ;Promthaisong, PitakSkullong, SompolThe paper presents an experimental study of convection enhancement in a tube heat exchanger using louvered curved-baffle (LCB) vortex generator (VG). The heat transfer and pressure loss of air as a working fluid, flowing in an isothermal-fluxed tube were measured having Reynolds numbers (Re) between 4760 and 29,300. The LCB elements were arrayed on two tape sides in a V-shape with a 30° attack angle. At a fixed baffle height, the LCB had three axial pitch ratios (PR) from 0.5 to 1.5 and six louver angles (θ) from 0° to 90°. Thermal enhancement factor (TEF), Nusselt number (Nu), and friction factor (f) are often utilized to analyze the effect of VG geometrical variables on thermohydraulic performance. The measured results demonstrated that the LCB-inserted tube has a significantly larger Nu and f than a plain tube functioning alone, and that the Nu and f tend to rise when PR and θ decline. Using the LCB increases Nu and f by approximately 2.59-4.66 and 3.8-39.37 times, respectively. The maximal TEF is achieved for the LCB at PR = 1, θ = 45° and lower Re. Empirical correlations for Nu and f were evaluated and found to fit measured data well, with discrepancies by ± 9% and ±10%, respectively. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal performance evaluation of a channel with twisted baffles installed: Effect of twisted baffle arrangement(2026-03-01) ;Eiamsa-ard, S. ;Pingta, S. ;Phila, A. ;Woncharee, K.Chamoli, S.This research aims to introduce newly designed twisted baffle for enhancing heat transfer in solar air heater. This study examined the thermo-hydraulic performance of converging twisted baffles (C-TBs) and diverging twisted baffles (D-TBs) with different numbers of loops (n = 2, 4, 6, and 8) over a Reynolds number range (Re) of 6000–24,000. The results demonstrated that both converging twisted baffles and diverging twisted baffles significantly enhanced heat transfer compared to a smooth channel. The Nusselt number, friction factor, and thermal performance factor (TPF) increased as the number of loops decreased, attributed to stronger flow reattachment. Specifically, twisted baffles with 2, 4, 6, and 8 loops enhanced Nu by approximately 2.29–3.43, 2.02–3.05, 1.77–2.74, and 1.61–2.48 times, respectively, while the friction factor increased by 5.19–5.71, 4.61–5.01, 4.06–4.43, and 3.73–4.06 times, respectively. For a given number of loops, diverging twisted baffles consistently provided higher heat transfer enhancement than converging twisted baffles, albeit with slightly increased friction losses. Across the investigated range, the 2-loop diverging twisted baffles exhibited the best overall performance, achieving the highest Nusselt number ratio (Nu/Nu<inf>SC</inf> where Nu<inf>SC</inf> is the Nusselt number of the smooth channel) of 3.43 and a maximum thermal performance factor of 1.92 at Reynolds number of 6000, establishing it as the optimal configuration among those tested. This research contributes valuable design guidelines for selecting optimal baffle configurations, thereby supporting the development of more energy-efficient solar thermal systems. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal-hydraulic performance of solar receiver duct with inclined punched-ribs and grooves(2022-11-01); ; ; Skullong, SompolThe article presents an experimental study on turbulent airflow friction and thermal behaviors in a solar receiver heat exchanger duct mounted with combined inclined chamfered-groove and turbulators. The experimental work was conducted for Reynolds numbers from 5,300 to 24,000, based on the hydraulic duct diameter. The 45°-inclined punched-ribs and grooves were placed periodically on the absorber plate. The punched-rib parameters were four inclination angles (β = 0°, 45°, 90° and 135°) of the punched holes and three relative rib pitches (PR = 1, 1.5 and 2) whereas only a rib blockage ratio (BR = 0.5) and an angle of attack (α) of 45° were fixed. Similarly, the parameters of the grooves included only three groove-pitch ratios (PR), similar to the rib pitches and one groove blockage ratio (BR = 0.2). The experimental result has revealed that the combination of rib-groove turbulators at β = 0° (solid rib) and PR = 1 gives the maximum heat transfer rate and friction loss while the greatest thermal enhancement factor of 2.1 was found at β = 45°, PR = 1. Moreover, the friction loss and heat transfer correlations for this thermal system were determined. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Experimental investigation and ANN prediction of heat transfer enhancement in a heat exchanger tube utilizing twin corrugated twisted tapes(2025-12-01) ;Du, Y. ;Wongcharee, K.; ; Chamoli, S.This report introduces a novel twin-corrugated twisted tape (TC-TT) insert designed to enhance heat transfer in exchanger tubes. The key innovation lies in the twin-corrugated structure, which generates a twin-swirl flow effect. The corrugated surface synergistically increases flow disturbance and expands the effective heat transfer area. The studied parameters were twist ratios (y/w = 3.0, 3.5, and 4.0) and corrugation angles (θ = 45°, 60°, 75°, and 90°) at 6,000 ≤ Re ≤ 20,000. The results show that using twin-corrugated twisted tapes increases the average Nusselt number by roughly 60–135% compared to a plain tube and by 16–35% compared to a conventional single-twisted tape, confirming the effectiveness of this structural modification. This enhancement is primarily due to the combination of double swirling-flows and enhanced effective heat transfer generated by the corrugated surface. Reducing the corrugation angle (θ) and twist ratio (y/w) led to increases in the Nusselt number (Nu), friction factor (f), and thermal performance factor (TPF). Within the studied range, the Nusselt number, friction factor, and thermal performance factor reached maximum values of 5.18, 0.153, and 1.44, respectively, at a twist ratio of 3.0, a corrugation angle of 45°, and Re = 6,000. Regression analysis was utilized to develop correlations for the Nu and f, considering the Re, Pr, y/w, and θ as influencing variables. The proposed correlations for predicting the friction factor and Nusselt number have errors within ±3% and ±2%, respectively. In addition, an artificial neural network (ANN) was developed for predicting the thermal performance values occurring below the experimental study range. The optimal state ANN model shows remarkable prediction accuracy with R<sup>2</sup> of 0.965.
