    Item type:Publication,
    Classification of Capacitor Bank Switching Using Fuzzy Interference Systems in 230 kV Substation
    (2024-01-01)
    Patcharoen, Theerasak
    ;
    ; ; ;
    Lertwanitrot, Praikanok
    Flexible AC transmission systems are used for enhancing the stability, transmission efficiency, and reliability of AC grids. Additionally, the most cost-effective devices for compensating reactive power are Mechanically Switched Capacitors (MSCs). This study proposes a novel algorithm for detection and capacitor bank switching transient signals in MSC, to prevent the protective relay maloperation by these transients. The Discrete wavelet transform (DWT) is used for effective time-frequency analysis and detection of measured three-phase current signals. DWT extracts the detailed wavelet coefficients of current signals at levels 1 to 30. In addition, the fuzzy inference system (FIS) has been used to determine the type of switching transient. The proposed combination of FIS and DWT has been tested on 230 kV substation and the result demonstrated precision for the identification and classification of both transient signals in MSC with 88% accuracy rate.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Effects of Conditional Changes on High-Voltage Direct Current Transmission Line Characteristic
    (2022-01-01) ; ;
    Leelajindakrairerk, Monthon
    ;
    Phannil, Natthanon
    ;
    Bunjongjit, Sulee
    The high-voltage direct current (HVDC) transmission system, which links the Gurun Substation of the National Electric Authority of Malaysia (Tenaga Nasional Berhad, TNB) with the Khlong Ngae Station of the Electricity Generating Authority of Thailand (EGAT), has been extensively researched to achieve the highest quality because it is the largest of its kind in Thailand, and there is a plant to expand its transmission power. However, the impact on the whole system is under-researched. To study and develop this system, the HVDC transmission line is modelled with the MATLAB/Simulink program and a laboratory setup to investigate the effect of transmission line distance, load power, and voltage on power loss, voltage drop, and waveform. The HVDC transmission line parameters are calculated from the actual transmission line parameters and converted to the simulation model parameters using the per-unit method. The model is verified and tested by the simulation program before creating the experimental setup. The simulation and experimental results demonstrate the effects of changing system conditions via the three aspects. All the three conditions directly affect the HVDC transmission line; nevertheless, they affect each aspect differently.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    A phase diagram approach to the detection and location of faulty capacitor units in A 115-kV capacitor bank based on unbalanced current arguments
    (2023-03-01) ;
    Lertwanitrot, Praikanok
    ;
    The protection of traditional high voltage capacitor banks relies on an unbalance relay which operates when an internal fuse is blown. However, the unbalance relay cannot indicate cause or position of the fault. Thus, an operator wastes time and human resources investigating the fault issues. To address this issue, a method to locate the fault position in a capacitor bank is developed in this study. The study was simulated by using PSCAD software and modeled on the 115-kV system of the Electricity Generating Authority of Thailand (EGAT). Case studies involving faults with varied phases, side and branch connections, row connections, and inception angles were considered. Moreover, the magnitude and argument of the current phase and unbalanced current were analyzed to identify the fault location in a capacitor bank. The performance of the proposed method was verified via comparison with that of traditional methods and the results of laboratory experiments. In addition, various voltage systems were observed to verify the flexibility and accuracy of the proposed method. The results demonstrate that the proposed method was more efficient than traditional methods at locating the fault position in a capacitor bank.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Behaviour analysis of H-bridge high-voltage capacitor banks fault on 230-kV substation using discrete wavelet transform
    (2023-11-01)
    Chiradeja, Pathomthat
    ;
    Lertwanitrot, Praikanok
    ;
    ;
    The protection of traditional high-voltage capacitor banks relies on an unbalance relay which operates when an internal fuse is blown. However, the unbalance relay cannot indicate the cause of the fault. Thus, an operator wastes time and human resources investigating the fault issues. In this paper, a fault which occurred in a 230-kV power system of Electricity Generating Authority of Thailand was observed by performing simulations using the Power Systems Computer Aided Design (PSCAD) program. The study system based on the double bus station and 72 MVAR capacitor banks was installed in the form of a back-to-back topology. Three scenarios were considered: normal condition, fault occurrence in one capacitor bank and fault occurrence in both capacitor banks. Current characteristics such as the current phase and difference in unbalance current were considered. In addition, discrete wavelet transform was applied to solve the ambiguity of current generated from the PSCAD. The authors’ results suggest that identifying fault events using a coefficient of wavelet is more efficient than relying on the current amplitude. The findings mentioned in this paper can be applied in a traditional power system protection scheme to enhance a system's reliability.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    An Evaluation Study on Electric Appliance Characteristics and Load Patterns in Residential Buildings
    (2026-01-01)
    Thongsuk, Surakit
    ;
    Songsukthawan, Panapong
    ;
    ;
    Sottiyaphai, Chayanut
    ;
    Energy usage in residential buildings has been constantly increasing as work-from-home trends continue to maintain popularity. To improve energy efficiency, the load profile and electric appliances in households need to be established and analyzed. This study aims to evaluate the characteristics of electric appliances that are commonly used in residential buildings under various operating conditions. An experimental setup with household electric appliances was built, and power quality meters were installed to assess the patterns under various operating conditions. In addition, the usage patterns were used to construct the daily load profile and analyze the energy consumption in residential buildings. The results demonstrate that load patterns constructed from actual measurements can achieve an accurate depiction of energy usage in residential buildings. The obtained load profile can be used in load control to improve energy efficiency and the application of renewable energy in demand reduction.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Wavelet Transform and Artificial Intelligence for Unbalanced Current Protection of 230kV Capacitor Switching Transient Inrush Current
    High transient inrush currents from back-to-back capacitor switching can cause the maloperation of protective relays, especially the instantaneous overcurrent (50) and unbalanced current protection relays (60C). This paper presents a combination of discrete wavelet transforms and artificial intelligence as an efficient technique to analyze the inrush current switching. The discrete wavelet transform is used to detect and classify either isolated or back-to-back capacitor switching transient signals. After that, the output from wavelet coefficients acts as the artificial intelligence input for discriminating the 6-difference cases of transient inrush current mitigation methods by using the combination of discrete wavelet transform and fuzzy inference system and discrete wavelet transform and probabilistic neural network. The proposed technique of discrete wavelet transform for detection and classification shows enhanced performance accuracy of 100 %. The fuzzy inference system and probabilistic neural network that can discriminate the inrush current mitigation methods have a high accuracy of 90.57 % and 96.72 %, respectively.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Study on Installation of Neutral Ground Resistance in Very Small Power Plant Transformer
    (2022-01-01)
    Chiradeja, Pathomthat
    ;
    ;
    Srisuksai, Panu
    ;
    ;
    Faults in the distribution system of the Thai electrical system occur frequently. Such faults directly affect the protective equipment of the distribution system. The protective device disconnects the circuit unnecessarily on many occasions because it detects a higher current than expected. In this study, a 22-kV distribution system and a very small power plant (VSPP) were connected. The system consists of two feeders. Feeder 1 supplies electricity directly to the load; a fault was enforced in this feeder. Feeder 2 supplies electricity directly to the load; the VSPP was connected to this feeder. The fault in Feeder 1 was simulated, and the behavior of the defense system was studied. Unnecessary disconnection of the VSPP circuit took place because the high fault current caused the overcurrent protection relay to operate instantaneously. Therefore, a neutral ground resistance was installed at the VSPP transformer to reduce the fault current, extend the relay operating time to the delay range, and reduce unnecessary disconnections of the overcurrent protection relay of the VSPP. In addition, when a fault occurs in the distribution system, the faulted phase voltage decreases, whereas the non-faulted phase voltage increases. Surge arresters and voltage transformers must be able to withstand an increase in voltage. This is also explained and discussed in this paper.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Design and techno-economic evaluation of a nanogrid system for a small-scale public railway station building in Thailand
    (2025-12-01) ;
    Songsukthawan, Panapong
    ;
    Bunjongjit, Sulee
    ;
    Sreewirote, Bancha
    ;
    In Thailand, numerous small-scale public facilities continue to rely on the electrical grid. The integration of renewable energy sources such as photovoltaic (PV) and wind power offers a sustainable alternative; however, their inherent intermittency necessitates advanced solutions such as nanogrid systems, which enable localized energy generation, storage, and management to enhance reliability and autonomy. This study develops a nanogrid-based energy management system for Hua Takhe train station, Thailand, by integrating photovoltaic (PV) panels, wind turbines, and battery energy storage systems (BESS). Using HOMER Pro, multiple configurations were simulated and evaluated across key financial indicators, including Payback Period (PB), Internal Rate of Return (IRR), Return on Investment (ROI), Net Present Value (NPV), and Levelized Cost of Electricity (LCOE). The analysis framework further incorporates economic feasibility evaluation, sensitivity and scenario analysis, and long-term performance and life cycle evaluation, thereby ensuring that both short-term financial viability and long-term sustainability are comprehensively assessed. Results show that PV-dominant nanogrid systems, particularly at larger scales, represent the most practical and cost-effective pathway for sustainable electrification of public facilities in Thailand. The 30PV Nanogrid achieves the most favorable balance between cost and performance, with a NPV of 23,925 USD, a LCOE of 0.04 USD/kWh, a PB of 7 years, an IRR of 13 %, and a ROI of 215 % under long-term life-cycle evaluation. In comparison, the 15PV Nanogrid proves economically marginal, with NPV falling to –9117 USD, PB extending beyond 20 years, IRR turning negative (–5 %), and ROI declining to –40 %, confirming that small-scale nanogrids cannot offset the costs of ESS and hybrid inverters.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Power Quality Improvement Based on Active Harmonic Filter in 24 kV Liquefied Natural Gas Industrial Plant’s Photovoltaic System
    (2026-06-01) ;
    Patcharoen, Theerasak
    ;
    Lothongkam, Chaiyaporn
    ;
    ;
    Lertwanitrot, Praikanok
    This paper presents a case study demonstrating the power quality improvements in a 24 kV distribution system at a liquefied natural gas (LNG) industrial plant with variable speed drives (VSDs), the conventional capacitor bank, and a rooftop solar photovoltaic system. Solar photovoltaic (PV) inverters can supply harmonic currents to the grid, potentially affecting the system and causing maloperation of sensitive equipment in both the utility systems and neighboring industries connected to it. Therefore, the installation of shunt active power filters (APFs) in a 400 V system was proposed in this study. The installed locations were varied, and the corresponding power qualities were analyzed. The results were examined in terms of design and harmonic elimination. Simulations were conducted using the PSCAD/EMTDC software version 4.5. The power quality simulation and field measurement results after the APF installation were compared to demonstrate the effectiveness of the proposed solutions. The addition of APFs was found to improve the power quality. In addition to the mechanism analysis, the economic feasibility of the proposed approach was investigated. The costs of APF installation in various locations were analyzed. The results show that the proposed method can improve the power supply at a reasonable price. This work contributes to sustainable industrial energy systems by improving the reliability and power quality of photovoltaic-integrated electrical networks, thereby supporting higher penetration of renewable energy resources and stable low-carbon industrial operation.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    An Approach for Voltage Drop Improvement in Distribution Line Using High-Voltage Capacitor Bank
    (2025-01-01)
    Songsukthawan, Panapong
    ;
    ;
    Thongsuk, Surakit
    ;
    Phannil, Natthanon
    ;
    Bunjongjit, Sulee
    Distribution line voltage drops cause power losses and a general decline in the efficiency of the electrical power system. In this study, PSCAD software is used to evaluate the elements that impact the voltage drop in the distribution line, including distribution line length, electric load power factor, and electric load capacity, both with and without capacitor bank installation. The 22-kV overhead distribution line in Thailand served as the basis for the simulation model’s creation. It has been suggested to install capacitor bank-based techniques to increase voltage on distribution lines. The findings show that the voltage drop is significantly influenced by the distribution line distance, electric load power factor, and electric load capacity. The voltage drop can be minimized to the greatest extent by properly arranging capacitor banks.