Item type:Publication, Classification of Capacitor Bank Switching Using Fuzzy Interference Systems in 230 kV Substation(2024-01-01) ;Patcharoen, Theerasak; ; ; Lertwanitrot, PraikanokFlexible AC transmission systems are used for enhancing the stability, transmission efficiency, and reliability of AC grids. Additionally, the most cost-effective devices for compensating reactive power are Mechanically Switched Capacitors (MSCs). This study proposes a novel algorithm for detection and capacitor bank switching transient signals in MSC, to prevent the protective relay maloperation by these transients. The Discrete wavelet transform (DWT) is used for effective time-frequency analysis and detection of measured three-phase current signals. DWT extracts the detailed wavelet coefficients of current signals at levels 1 to 30. In addition, the fuzzy inference system (FIS) has been used to determine the type of switching transient. The proposed combination of FIS and DWT has been tested on 230 kV substation and the result demonstrated precision for the identification and classification of both transient signals in MSC with 88% accuracy rate. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, SOH- and Temperature-Aware Adaptive SOC Boundaries for Second-Life Li-Ion Batteries in Off-Grid PV–BESSs(2026-02-01) ;Wang, Hongyan; In this study, an adaptive state-of-charge (SOC) boundary strategy (ASBS) is proposed that dynamically adjusts the admissible upper and lower SOC limits of second-life lithium-ion batteries in off-grid photovoltaic battery energy storage systems (PV-BESSs) based on real-time state of health (SOH) and temperature feedback. The strategy is formulated using a unified electrical–thermal–aging model with an online state estimator and ensures both electrical safety and power feasibility while remaining fully compatible with standard energy management functions. Two representative simulations—a single-day operating profile and a continuous thirty-day sequence—demonstrate the effectiveness of the ASBS. In the twenty-four-hour case, the duration spent in high state-of-charge conditions is reduced by approximately 0.30–0.50 h, the abrupt end-of-charging transition is eliminated, and the temperature rise is slightly moderated, all without any loss of energy supply. Over thirty days, the difference between the ASBS and a fixed state-of-charge window remains effectively zero for almost all hours, with only a brief midday deviation of −4 to −5 percentage points and no cumulative drift. Indicators of electrical and thermal stress improve substantially, including an approximate 70% reduction in the root mean square charging current. These results confirm that the ASBS provides a practical and non-intrusive means of mitigating stress on second-life lithium-ion batteries while preserving full energy autonomy in off-grid photovoltaic systems. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Comparison of artificial intelligence methods for fault classification of the 115-kv hybrid transmission system(2020-06-01) ;Klomjit, JittiphongThis research proposes a comparison study on different artificial intelligence (AI) methods for classifying faults in hybrid transmission line systems. The 115-kV hybrid transmission line in the Provincial Electricity Authority (PEA-Thailand) system, which is a single circuit single conductor transmission line, is studied. Fault signals in the transmission line were generated by the EMTP/ATPDraw software. Various factors such as fault location, type, and angle were considered. Then, fault signals were analyzed by coefficient details on the first scale of the discrete wavelet transform. Daubechies mother wavelet from MATLAB software was used to decompose the fault signal. The coefficient value of the mother wavelet behaved depending on the position, inception of fault angle, and fault type. AI methods including probabilistic neural networks (PNNs), back-propagation neural networks (BPNNs), and support vector machine (SVM) were used to identify faults. AI input used the maximum first peak coefficients of phase ABC and zero sequence. The results obtained from the study were found to be satisfactory with all AI methodologies having an average accuracy of more than 98% in the case study. However, the SVM technique can provide more accurate results than the PNN and BPNN techniques with less computation burden. Thus, it is suitable for being applied to actual protection systems. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Effects of Conditional Changes on High-Voltage Direct Current Transmission Line Characteristic(2022-01-01); ; ;Leelajindakrairerk, Monthon ;Phannil, NatthanonBunjongjit, SuleeThe high-voltage direct current (HVDC) transmission system, which links the Gurun Substation of the National Electric Authority of Malaysia (Tenaga Nasional Berhad, TNB) with the Khlong Ngae Station of the Electricity Generating Authority of Thailand (EGAT), has been extensively researched to achieve the highest quality because it is the largest of its kind in Thailand, and there is a plant to expand its transmission power. However, the impact on the whole system is under-researched. To study and develop this system, the HVDC transmission line is modelled with the MATLAB/Simulink program and a laboratory setup to investigate the effect of transmission line distance, load power, and voltage on power loss, voltage drop, and waveform. The HVDC transmission line parameters are calculated from the actual transmission line parameters and converted to the simulation model parameters using the per-unit method. The model is verified and tested by the simulation program before creating the experimental setup. The simulation and experimental results demonstrate the effects of changing system conditions via the three aspects. All the three conditions directly affect the HVDC transmission line; nevertheless, they affect each aspect differently. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, A phase diagram approach to the detection and location of faulty capacitor units in A 115-kV capacitor bank based on unbalanced current arguments(2023-03-01); ;Lertwanitrot, PraikanokThe protection of traditional high voltage capacitor banks relies on an unbalance relay which operates when an internal fuse is blown. However, the unbalance relay cannot indicate cause or position of the fault. Thus, an operator wastes time and human resources investigating the fault issues. To address this issue, a method to locate the fault position in a capacitor bank is developed in this study. The study was simulated by using PSCAD software and modeled on the 115-kV system of the Electricity Generating Authority of Thailand (EGAT). Case studies involving faults with varied phases, side and branch connections, row connections, and inception angles were considered. Moreover, the magnitude and argument of the current phase and unbalanced current were analyzed to identify the fault location in a capacitor bank. The performance of the proposed method was verified via comparison with that of traditional methods and the results of laboratory experiments. In addition, various voltage systems were observed to verify the flexibility and accuracy of the proposed method. The results demonstrate that the proposed method was more efficient than traditional methods at locating the fault position in a capacitor bank. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Design and application of daylight-based lighting controller on LED luminaire(2020-05-01) ;Bunjongjit, Sulee; ; ; Patcharoen, TheerasakThis paper proposes a control circuit for Light Emitting Diode (LED) luminaire based on the amount of daylight. This system uses both natural daylight and artificial light from a luminaire to reach the desired illuminance on a working plane. The control circuit operates by receiving an illuminance value from a light sensor and comparing it with a set value in the microcontroller before limiting the light intensity of LED by sending a control Pulse Width Modulation (PWM) signal to the LED driver. In the experimental setup, the controller and a physical model of a working space were built in order to field test the LED daylight control circuit. Electrical characteristics such as voltage, current, and power were measured with a power meter. Illumination characteristics in terms of illuminance on a working plane were determined using a lux meter. The results from actual field tests revealed that this LED control circuit was able to reduce the power consumption of the lighting system while keeping the illuminance on the working plane at the standard value. Both simulation results and the actual experiment of the control circuit proved that it could be used to improve the energy efficiency of both newly installed and retrofitted lighting systems. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Evaluation of Light-Emitting Diode Luminaire For Two-Lanes Roadway Lighting System(2024-01-01) ;Wannapasert, Padungsak; Lighting systems for roadways are an important aspect of the transportation system in terms of safety and providing comfort for drivers. Conventional lighting systems use high-pressure sodium luminaires, which consume a lot of energy. This paper proposes an evaluation of roadway lighting using lightemitting diodes (LEDs) as luminaires. The paper uses a two-lane road as a case study and simulates the lighting parameters using DIALux software. The case study varies the wattage of the luminaires, pole distances, and pole arrangements, while keeping the pole specifications fixed. The parameters under consideration include illuminance, luminance, and uniformity on the road surface. Additionally, the results are compared with international criteria standards to confirm that the selected LED luminaires can provide the necessary lighting quality for road usage. The results show that LED luminaires can provide lighting quality within standard criteria. However, different pole arrangements require different levels of wattage and pole distances. Therefore, the selection of LEDs needs to match the design of pole distances and arrangements to provide sufficient roadway lighting. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Development and Analysis of a Fast-Charge EV-Charging Station Model for Power Quality Assessment in Distribution Systems(2025-09-01) ;Chiradeja, Pathomthat; ;Srisuksai, Panu ;Klomjit, JittiphongWith the rapid rise in electric vehicle (EV) adoption, the deployment of EV charging infrastructure—particularly fast-charging stations—has expanded significantly to meet growing energy demands. While fast charging offers the advantage of reduced charging time and improved user convenience, it imposes considerable stress on existing power distribution systems due to its high power and current requirements. This study investigated the impact of EV fast charging on power quality within Thailand’s distribution network, emphasizing compliance with accepted standards such as IEEE Std 519-2014. We developed a control-oriented EV-charging station model in power systems computer-aided design and electromagnetic transients, including DC (PSCAD/EMTDC), which integrates grid-side vector control with DC fast-charging (CC/CV) behavior. Active/reactive power setpoints were mapped onto (Formula presented.) current references via Park’s transformation and regulated by proportional integral (PI) controllers with sinusoidal pulse-width modulation (SPWM) to command the voltage source converter (VSC) switches. The model enabled dynamic studies across battery state-of-charge and staggered charging schedules while monitoring voltage, current, and total harmonic distortion (THD) at both transformer sides, charger AC terminals, and DC adapters. Across all scenarios, the developed control achieved grid-current THDi of <5% and voltage THD of <1.5%, thereby meeting IEEE 519-2014 limits. These quantitative results show that the proposed, implementation-ready approach maintains acceptable power quality under diverse fast-charging patterns and provides actionable guidance for planning and scaling EV fast-charging infrastructure in Thailand’s urban networks. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Comparative Fault Detection Between DWT and STFT in Overcurrent Relays(2024-01-01) ;Chiradeja, Pathomthat; ;Lertwanitrot, Praikanok; This study proposes a protection relay using a microcontroller to detect and classify faults in transmission lines based on the Wavelet transform. An experimental model was constructed from an actual 115 kV transmission system prototype. The current signal was observed based on the fault type, phase, and position. Clark's transform and the discrete Wavelet transform (DWT) were applied to transform signals for analysis. The positive and zero sequences obtained from Clark's transform were used for fault detection and fault classification, respectively. Moreover, the performances between the DWT and the short-time Fourier Transform (STFT) were compared in terms of accuracy and processing time. In addition, the double-detection technique was used to confirm the accuracy of fault detection. Results show that the proposed method is efficient for fault detection and classification. This finding allows the researcher to choose the appropriate analytical method. Moreover, it can also be used as the basis for overcurrent relay algorithm design in the effort to develop more advanced technologies. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Analysis of Investment Feasibility for EV Charging Stations in Residential Buildings(2025-09-01) ;Chiradeja, Pathomthat; ;Sottiyaphai, Chayanut; Klomjit, JittiphongThis study investigates the financial and operational feasibility of deploying electric vehicle (EV) charging infrastructure within high-density residential buildings, utilizing empirical operational data combined with comprehensive financial modeling. A 14-day monitoring period conducted at a residential complex comprising 958 units revealed distinct charging behaviors, with demand peaking during weekday evenings between 19:00 and 22:00 and displaying more dispersed yet lower overall utilization during weekends. Energy efficiency emerged as a significant operational constraint, as standby power consumption contributed substantially to total energy losses. Specifically, while total energy consumption reached 248.342 kW, only 138.24 kW were directly delivered to users, underscoring the necessity for energy-efficient hardware and intelligent load management systems to minimize idle consumption. The financial analysis identified pricing as the most critical determinant of project viability. Under current cost structures, financial break-even was attainable only at a profit margin of 0.2286 USD (8 THB) per kWh, while lower margins resulted in persistent financial deficits. Sensitivity analysis further demonstrated the considerable vulnerability of the project’s financial performance to small fluctuations in profit share and utilization rate. A 10% reduction in either parameter entirely eliminated the project’s ability to reach payback, while variations in energy costs, capital expenditures (CAPEX), and operational expenditures (OPEX) exerted comparatively limited influence. These findings emphasize the importance of precise demand forecasting, adaptive pricing strategies, and proactive government intervention to mitigate financial risks associated with residential EV charging deployment. Policy measures such as capital subsidies, technical regulations, and transparent pricing frameworks are essential to incentivize private sector investment and support sustainable expansion of EV infrastructure in residential sectors.