Now showing 1 - 3 of 3
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Effect of arc-shaped twisted-baffles on augmented heat transfer in a rectangular duct
    (2023-02-01) ;
    Phila, Arnut
    ;
    ;
    Chokphoemphun, Suriya
    ;
    Eiamsa-Ard, Smith
    In this current work, the effect of utilizing arc-shaped twisted-baffles (T-ABs) in a rectangular air channel on thermal performance factor (TPF) has been experimentally studied. In these experiments, the influence of the changes in parameters such as dimensions of pitch ratio (p/w), attached arc-shape angle (α), and Reynolds number (Re) are explored. The comparisons demonstrate that a channel mounted with arc-shaped twisted-baffles yielded considerably greater Nusselt numbers than a smooth channel, possibly attributable to multiple-impinging jets near the channel surface. Heat transfer enhancements of twisted arc-shaped baffles (T-AB) having larger attack angles were superior to those having smaller attack angles. The one with α = 90o offered greater heat transfer rates than the ones with α = 20o, 40o, 60o, and 80o by approximately 8%, 7%, 4%, and 2%, respectively. The superior heat transfer was attributed to the better contact between the working fluid and heat transfer surfaces. In addition, utilizing arc-shaped twisted-baffles with the lowest p/w of 4.0, in a channel produced stronger vortices and multiple impinging jets, which caused better fluid mixing than other p/w. The optimum condition is achieved using T-ABs at an attached arc-shape angle of α = 90o, p/w = 4.0 and Re = 4000, where the heat transfer rate (Nu), friction factor (f) and TPF are found to be, respectively, 3.31, 4.68 and 1.98 times greater than those of a plain channel.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Influence of sawtooth twisted tape on thermal enhancement of heat exchanger tube
    (2023-03-01)
    Samutpraphut, Boonsong
    ;
    Eiamsa-ard, Smith
    ;
    ; ;
    Maruyama, Naoki
    This article employs sawtooth twisted tapes to generate swirling flow and interrupted flowing disturbance in order to increase the level of heat transfer rate. The influences of the sawtooth twisted tape (S-TT) on enhanced heat transfer rate, friction factor and aerothermal performance index (API) behaviors are analyzed. The sawtooth twisted tapes (S-TTs) possessing constant pitch/twist ratio (y//W) of 3.0 and six sawtooth angles (α) of 20°, 30°, 40°, 50°, 60°, and 70° are assessed. Considering turbulent flow using air as the testing fluid, experiments were investigated at 6,000 < Re < 20,000 under boundary conditions of constant heat flux. According to the experimental findings, sawtooth twisted tape (S-TT) improves heat transfer rate and raises pressure loss with varying rates based on sawtooth angles (α). With the sawtooth twisted tape (S-TT) and 70° sawtooth angles, the optimum API of 1.33 is attained, while Nusselt number and friction factor are 32 and 0.135 at Re = 6,000. The recommended sawtooth twisted tape (S-TT) yields a highest Nusselt number of 78, which is 1.6 times greater than the typical twisted tape (TT) and 1.1 times greater than the plain tube. The combination of the TT and sawtooth patterns can be beneficial in terms of boosting heat transfer rate and API relating coupling of swirling flow and interrupted flowing disruption effects since the sawtooth twisted tape (S-TT) offers superior performance than the TT. Additionally, the heat exchanger tubes fitted with sawtooth twisted tape (S-TT) at sawtooth angles (α) of 20°, 30°, 40°, 50°, 60°, and 70° gain greater Nusselt number than the plain tube up to 158.3%, 162.2%, 166.1%, 171.7%, 179.7% and 186.2%, respectively.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Enhanced heat transfer performance in channel with delta-wing perforated V-type baffles
    (2023-10-01)
    Eiamsa-ard, Smith
    ;
    Phila, Arnut
    ;
    ; ;
    Maruyama, Naoki
    The article examines the influence of delta-wing V-type baffles (DW-PVBs) on the average Nusselt number, local Nusselt number distribution, pressure losses, and thermal performance behaviors in a channel. Delta-wing perforated V-type baffles (DW-PVBs) mounted in a regular manner on the bottom of a channel produced two pairs of longitudinal counter-rotating vortices to enhance chaotic fluid mixing and destabilize the boundary layer, hence boosting the heat transfer. The geometric characteristics of the delta-wing V-type baffle (DW-PVBs) located on the bottom of the channel were examined at relative baffle blockage and pitch ratios (BR = h/H = 0.3 and p/H = 1.5), and five delta-wing attack angles, θ = 0<sup>o</sup> (solid V-shaped baffle), 22.5°, 45°, 67.5°, and 90°. The present DW-PVBs mounted on the channel were designed to mitigate pressure loss due to flow blockage. The experiment was done by permitting air to flow through a channel at Reynolds numbers (Re) ranging from 6000 to 24,000. The present results show that the friction factor using the DW-PVBs decreased considerably with increasing θ values. The experimental results revealed that small θ values yielded greater heat transfer and resistance than large θ values. The DW-PVBs with θ = 22.5° performed better than inserts with other θ values in terms of heat transfer rate. It was also observed that the DW-PVBs with θ = 45° gave the maximum thermal performance factor (TPF), while presenting a 13.64–17.26% lower friction factor than the solid V-shaped baffle. Furthermore, it was also found that the DW-PVBs with θ = 0°, 22.5°, 45°, 67.5°, and 90° gave peak TPF values of up to 1.87, 1.89, 1.91, 1.87, and 1.84 at the lowest Reynolds number, 6000.