Item type:Publication, Augmented thermal effectiveness in solar air receiver with flapped curved winglets: Experimental and numerical analysis(2025-12-01) ;Sripattanapipat, Somchai; ; ;Promthaisong, PitakNakhchi, Mahdi ErfanianThermal effectiveness was examined on a solar air receiver equipped with a new lengthwise vortex generator, namely a flapped curved winglet (FCW) mounted on the absorber, utilizing experimental and numerical approaches. Two arrays were employed to assemble two FCWs on the absorber at an angle of attack (α = 59.5°). The FCWs' V-tips were orientated upstream (VU-FCW) and downstream (VD-FCW). Air served as the working fluid, entering a constantly heat-fluxed channel at Reynolds numbers (Re) varying from 5280 to 22,510. Three relative winglet pitches (P<inf>R</inf> = P/H = 1.0–2.0), five winglet-mounted flap angles (β = 0° - 90°), and one winglet blockage ratio (b/H=B<inf>R</inf> = 0.6) were among the major factors. According to the findings, lowering P<inf>R</inf> and β greatly enhances the f (friction factor) and Nu (Nusselt number) of the two FCW arrays. The FCW with P<inf>R</inf> = 1.0 and β = 0° has the largest Nu and f values, approximately 8.3 and 77.39 times bigger than the smooth flat channel, as per the test data. The maximal thermal effectiveness factors (TEF) of the VD-FCW and VU-FCW were approximately 2.83 and 2.61, respectively, at comparable β = 45° and P<inf>R</inf> = 1.5. The f and Nu correlations in employing FCW were also provided. A 3D computational analysis employing the realizable k-ε turbulence model was conducted to examine heat transmission and flow patterns, with the corresponding measured data validating the expected results. The numerical and measured data sets yielded consistent results, and the FCW's heat transmission mechanism was also described. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Analysis of exergy and heat transfer in a tube fitted with flapped V-baffles(2024-07-01); ; ;Tongyote, Paritkavin ;Skullong, SompolNakhchi, Mahdi ErfanianVortex generator is a device that shows promise in generating streamwise vortices that can be utilized for boosting the rate of heat transmission inside a cooling/heating system with a relatively smaller penalty in terms of friction loss. The primary goal of the current research is to maximize the comparative Nusselt number ratio (Nu/Nu<inf>0</inf>) to be as large as possible to lower the size of the system while keeping thermal performance as high as feasible to save more energy. Thus, in the current study, the impacts of inserting the flapped V-baffle vortex generator (FBVG) on the thermal effectiveness improvement of a round tube were experimentally investigated. At a fixed attack angle (α = 60°) and baffle blockage ratio (B<inf>R</inf> = b/D = 0.3), the geometrical behaviors of FBVGs placed periodically along two edges of a straight tape were six different flap angles (θ = 0°, 25°, 35°, 45°, 65° and 90°) and three ratios of baffle pitches (P/D = P<inf>R</inf> = 2.0, 1.5, and 1.0). The current V-baffles, which were positioned on both tape edges, were designed to reduce friction loss caused by interrupting the central core flow when placed on both tape sides. The measurement results focused on the friction loss and thermal behaviors, including exergy and entropy analyses for Reynolds number from 4750 to 29,270. In the findings, the Nusselt number and friction factor of FBVG at θ = 0° and P<inf>R</inf> = 1 are, respectively, up to 5.6 and 35.24 times larger than those of the smooth tube. The entropy generation (S˙<inf>gen</inf><sup>′</sup>) seems to decline as θ and P<inf>R</inf> increase, with the smallest S˙<inf>gen</inf><sup>′</sup> found at θ = 0° and P<inf>R</inf> = 1 for lower Re. The FBVG has the greatest exergy efficiency (η<inf>Ex</inf>) at θ = 0° and P<inf>R</inf> = 1. To find the true benefits of FBVG, its thermal performance is estimated and seen to reach a maximum at about 2.44 with Nu<inf>R</inf> = 4.65 at θ = 45° and P<inf>R</inf> = 1. The optimal scenario at θ = 25° and P<inf>R</inf> = 1 was preferred, however, since it yielded the largest Nu<inf>R</inf> = 5.42 at TEF = 2.39. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Entropy generation and thermal performance of tubular heat exchanger fitted with louvered corner-curved V-baffles(2023-02-01); ; ; Skullong, SompolThe current article deals with an experimental study on entropy generation analysis and thermohydraulic performance of a uniform heat-flux tube equipped with louvered corner-curved baffle tape (LCBT). Air was drawn into the inserted tube for the Reynolds number (Re) between 4760 and 29,300. The V-shaped LCBT arranged by V-tip in downstream direction was introduced with three baffle pitch ratios (P<inf>R</inf> = 1–2) and six louver angles (θ = 0–90°) for a fixed attack angle (α) of 30° and baffle height ratio (B<inf>R</inf> = 0.25). The impacts of investigated parameters on the thermal enhancement factor (TEF), Nusselt number (Nu), friction factor (f), and total entropy generation (S˙<inf>gen</inf><sup>′</sup>) were examined. The measurements showed that the LCBT with the smallest values of P<inf>R</inf> = 1, θ = 0° give the largest Nu and f at about 4.4 and 19.2 times above the plain tube values, respectively. However, the greatest TEF around 2.23 was seen for employing the LCBT at P<inf>R</inf> = 1, θ = 45°. The entropy analysis also showed that the S˙<inf>gen</inf><sup>′</sup> is found to decline with the increment of P<inf>R</inf> and θ, whereas the minimal S˙<inf>gen</inf><sup>′</sup>is at P<inf>R</inf> = 1, θ = 0° for lower Re but at P<inf>R</inf> = 1, θ = 45° for higher Re. Furthermore, the Nu and f empirical correlations for employing LCBTs were also proposed. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal performance of heat exchanger tube inserted with curved-winglet tapes(2018-01-25) ;Skullong, Sompol; ; ; The paper deals with the effect of curved-winglet (CW) inserts on thermal and flow behaviors in a constant heat-fluxed tube. A straight tape is used to support the 45° CWs mounted repeatedly on both tape sides to generate two pairs of longitudinal counter-rotating vortices along the test tube in order to assist the chaotic flow mixing and to disrupt the boundary layer leading to faster rate of heat transfer. The airflow and heat transfer behaviors in the tube are examined for Reynolds number (Re) in the range of 4150–25,400. The curved-winglet tape (CWT) parameters involved are the winglet attack angle of 45° three relative winglet heights (b/D = B<inf>R</inf> = 0.1, 0.2 and 0.3) and winglet pitches, (P/D = P<inf>R</inf> = 0.5, 1.0 and 2.0). The investigation reveals that the maximum thermal enhancement factor (TEF) of the CWT is about 1.62 at B<inf>R</inf> = 0.1 and P<inf>R</inf> = 1.0. For further improvement, the CWT at B<inf>R</inf> = 0.1 and P<inf>R</inf> = 1.0 is modified by punching the CW to be the perforated-curved-winglet tape (P-CWT) to reduce the pressure loss. The P-CWT characteristics include five different punched hole diameters (d = 1.0, 1.5, 2.0, 2.5 and 3.0 mm). The experimental results show that TEF of all the P-CWTs is higher than that of the CWT and the maximum TEF of 1.76 higher than the CWT around 9% is found for d = 1.5 mm. To understand the flow pattern and heat transfer mechanism, a three-dimensional CFD investigation is also performed and for validation, the good agreement between numerical and experimental results is found. For experimental data, empirical correlations for Nu, f and TEF for the CWT and P-CWT inserts are also determined. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal effectiveness and entropy-exergy estimation in a tube with punched double V-winglets(2026-06-01); ;Sripattanapipat, Somchai; ;Erfanian Nakhchi, MahdiSkullong, SompolVortex generators are effective devices for enhancing heat transfer rates in heating or cooling systems with minimal frictional losses via the production of streamwise vortices. This research effort presents the perforated double V-winglet (P-DVW) and looks at how it affects heat transmission and friction when mounted inside a heat exchange tube that is consistently heated for producing multiple vortices whereas its flow is turbulent. Optimizing thermal performance for increased energy savings and maximizing the Nusselt number ( Nu ) to minimize heat exchanger size are the major goals. Thermal characteristics, including generated entropy and exergy efficiency, are explored in depth. A Reynolds number (Re) that varies from 4760 to 29,270 is employed to explore the friction and thermal features of the tube. The P-DVW parameters encompass attack angles of α<inf>2</inf> = 15° and α<inf>1</inf> = 30°, four porosity ratios ( A <inf>h</inf>/ A <inf>w</inf> = 0, 0.0188, 0.0523, and 0.1026), and three pitch ratios, P<inf>R</inf>, (0.75, 1, and 1.25), while maintaining a constant winglet height. At P<inf>R</inf> = 0.75 and A <inf>h</inf>/ A <inf>w</inf> = 0, the P-DVW exhibits peak f and Nu values around 23.83 and 5.31 times bigger than those of the plain tube, accordingly. Further, under the specified conditions, it yields minimal entropy production, while the optimal exergy efficiency is roughly 0.9829. The thermal effectiveness of P-DVW is anticipated to reach its maximum at 2.55 with Nu<inf>R</inf> = 4.54 at A <inf>h</inf>/ A <inf>w</inf> = 0.0523 and P<inf>R</inf> = 0.75 to reveal its actual benefits. Furthermore, the correlations of f , Nu , and TEF were determined for the examined range of values. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal behaviors in a round tube equipped with quadruple perforated-delta-winglet pairs(2017-01-01) ;Skullong, Sompol; ; The article deals with an experimental investigation of enhancing convective heat transfer in a heated circular tube with pairs of perforated-delta-winglets placed repeatedly on a perforated-cross-tape (PW-XT). The perforated-delta-winglets are placed in inline array and a triangular-hole is punched on each winglet to reduce the friction loss. The aim at using the PW-XT insert is to produce streamwise-vortex flows in the tube to reduce the thickness of thermal boundary layer and to increase fluid mixing of the flow. The involved winglet parameters are composed of relative winglet height or blockage ratio, (B<inf>R</inf> = b/D = 0.1, 0.15, 0.2 and 0.25) and relative winglet pitch or pitch ratio, (P<inf>R</inf> = P/D = 0.5, 1.0, 1.5 and 2.0) and those are performed at a single delta-winglet inclination/attack angle, α = 30° and a winglet porosity ratio, A<inf>p</inf>/A<inf>w</inf> = 0.359 for Reynolds number from 4180 to 26,000. The present results of heat transfer and pressure loss displayed in terms of respective Nusselt number (Nu) and friction factor (f) show that Nu increases with increasing B<inf>R</inf>but with decreasing P<inf>R</inf>. Nu for the PW-XT insert is in a range of 1.96–5.06 times while f increases around 2.06–35.68 times above the plain tube alone. To estimate the real merits of the PW-XT, the thermal enhancement factor (TEF) is evaluated and found to be a maximum around 1.902 at B<inf>R</inf> = 0.15, P<inf>R</inf> = 1.0. In comparison, the PW-XT gives considerably higher TEF than the typical four delta-winglet pairs placed on the cross-tape (TW-XT) having the highest TEF around 1.72. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Effect of trapezoidal louvered winglets on increased heat transfer and exergy in tubular heat exchanger(2024-10-01); ; ; ;Nakhchi, Mahdi ErfanianSkullong, SompolThe effect of inserting a trapezoidal louvered winglet tape (TLWT) into a uniformly heat-fluxed tube on its thermal effectiveness was studied experimentally. The exergy and entropy analyses for turbulent flows, as well as frictional loss and thermal features, were highlighted as key aspects of the experimental finding for the Reynolds number which measured between about 4700 and 30,000. Because fixing baffles to the curved shape of tube wall presented a challenge, the baffles were consequently positioned on double surfaces of a flat tape. Six values of the louver angle (θ<inf>1</inf> = 0°, 25°, 30°, 45°, 60°, and 90°) and three values of the relative pitch of winglet (P<inf>R</inf> = 1.0, 1.5, and 2.0) were employed in the arrangement of TLWTs, with the V-apex oriented upstream (V-up). Each of these had only a fixed height (B<inf>R</inf> = 0.25) and angle of attack (α = 30°). The winglets were utilized to induce streamwise vortices which can hinder the boundary layer formation, while the louvered openings were adopted to lessen pressure drop without significantly impacting the primary vortices. The experiment results disclosed that the smallest θ<inf>1</inf> and P<inf>R</inf> produced the largest relative friction factor (f<inf>R</inf>) and Nu<inf>R</inf>, which were about 13.57 and 4.04 times higher, while P<inf>R</inf> = 1 and θ<inf>1</inf> = 45° provide the greatest TEF of about 2.27. The greatest exergy efficiency (η<inf>Ex</inf>) resulting from the TLWT was reached at θ<inf>1</inf> = 0°, but the generation of entropy (S˙<inf>g</inf><sup>′</sup>) dropped with lowering θ<inf>1</inf> and Re. A further examination, however, showed that the best scenario with α = 60° and staggered arrays is more desirable since it yields the largest TEF of 2.45 at θ<inf>1</inf> = 45° and P<inf>R</inf> = 1. For the range of parameters under consideration, the Nu and f correlations were additionally established. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Effect of louvered curved-baffles on thermohydraulic performance in heat exchanger tube(2023-02-01); ; ; ;Promthaisong, PitakSkullong, SompolThe paper presents an experimental study of convection enhancement in a tube heat exchanger using louvered curved-baffle (LCB) vortex generator (VG). The heat transfer and pressure loss of air as a working fluid, flowing in an isothermal-fluxed tube were measured having Reynolds numbers (Re) between 4760 and 29,300. The LCB elements were arrayed on two tape sides in a V-shape with a 30° attack angle. At a fixed baffle height, the LCB had three axial pitch ratios (PR) from 0.5 to 1.5 and six louver angles (θ) from 0° to 90°. Thermal enhancement factor (TEF), Nusselt number (Nu), and friction factor (f) are often utilized to analyze the effect of VG geometrical variables on thermohydraulic performance. The measured results demonstrated that the LCB-inserted tube has a significantly larger Nu and f than a plain tube functioning alone, and that the Nu and f tend to rise when PR and θ decline. Using the LCB increases Nu and f by approximately 2.59-4.66 and 3.8-39.37 times, respectively. The maximal TEF is achieved for the LCB at PR = 1, θ = 45° and lower Re. Empirical correlations for Nu and f were evaluated and found to fit measured data well, with discrepancies by ± 9% and ±10%, respectively. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Numerical Heat Transfer Investigation in a Heat Exchanger Tube with Hexagonal Conical-ring Inserts(2016-11-01) ;Sripattanapipat, Somchai ;Tamna, Sombat; The hexagonal conical rings (HCR) modified from the typical conical ring (CR) are used as a turbulence promoter for producing the vortex flows to enhance the heat transfer rate in a heat exchanger tube. To reduce the pressure loss, the V-shaped HCR (V-HCR) obtained by cutting both symmetric plane of the cone-tip of HCR at 30°, 45°and 60°is offered in the present work. The tube fitted with V-HCR elements having a fixed inlet and outlet diameter is numerically investigated. The computation is carried out for Reynolds number in a range of 3000 to 20,000 in a uniform heat-fluxed test tube. The numerical results show that the V-HCR insert leads to much higher heat transfer than the typical CR/HCR insert or the smooth tube alone and also provides lower friction factor. The 30°V-shaped HCR gives the highest heat transfer and thermal performance due to the lowest friction loss, indicating the promising device of the V-HCR. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal effectiveness analysis of heat exchange tube with staggered louver-punched V-baffles(2024-12-01); ; ;Promthaisong, Pitak ;Nakhchi, Mahdi ErfanianSkullong, SompolAn experiment has been conducted to ascertain the optimal approach for enhancing the convective transmission of heat in a heat exchanger tube by periodically positioning staggered louver-punched V-baffle (SLVB) vortex generators on a perforated tape. The louver-punched V-baffles were staggered and set up with two patterns: V-apex directing upstream (VU) and downstream (VD), and each featured a louver-punched aperture to minimize friction loss. The aim of this work was to rise the thermal effectiveness as well as the Nusselt number ratio (Nu<inf>R</inf>) at optimal effectiveness in order to cut down on overall dimension of heat exchangers. Consequently, the research findings focused on behaviors of heat transmission and frictional loss, incorporating generated entropy, through a variety of Reynolds numbers (Re) spanning 29,270 to 4762. The SLVB elements were designed and placed in VU and VD forms using three relative pitches (P<inf>R</inf> = 0.5, 1.0, and 1.5) as well as six louver-flapped angles (θ = 0°, 10°, 20°, 30°, 45°, and 90°), all at the same attack angle (α = 52°), a baffle height ratio (B<inf>R</inf> = 0.3) and a louver size ratio (L<inf>R</inf> = 0.73). As demonstrated by the experiment, the θ = 20° generated the best heat transfer of all P<inf>R</inf> values, up to 6.55 times greater than the smooth tube, despite having a lower friction loss than the θ = 0° (solid baffle). At P<inf>R</inf> = 0.5, θ = 20° and smaller Re, the optimum thermal effectiveness factor (TEF) and Nu<inf>R</inf> values were, respectively, about 2.65 and 6.55 for the VU SLVB and 2.52 and 6.04 for the VD one. It implied that the TEF strategies can be utilized to anticipate the best effectiveness under identical scenarios. Also, correlations for the critical parameters, namely, Nu, f, and TEF, were estimated and documented.