Promvonge, Pongjet
Loading...
Preferred name
Promvonge, Pongjet
Alternative Name
Promvonge, P.
Main Affiliation
Email
pongjet.pr@kmitl.ac.th
46 results
Now showing 1 - 10 of 46
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Heat transfer augmentation in a wedge-ribbed channel using winglet vortex generators(2010-02-01) ;Chompookham, Teerapat; ; Experimental investigations have been carried out to study the effect of combined wedge ribs and winglet type vortex generators (WVGs) on heat transfer and friction loss behaviors for turbulent airflow through a constant heat flux channel. To create a reverse flow in the channel, two types of wedge (right-triangle) ribs are introduced: wedge ribs pointing downstream and pointing upstream. The arrangements of both rib types placed inside the opposite channel walls are in-line and staggered arrays. To generate longitudinal vortex flows through the tested section, two pairs of the WVGs with the attack angle of 60° are mounted on the test channel entrance. The test channel has an aspect ratio, AR = 10 and height, H = 30 mm with a rib height, e/H = 0.2 and rib pitch, P/H = 1.33. The flow rate in terms of Reynolds numbers is based on the inlet hydraulic diameter of the channel ranging from 5000 to 22,000. The presence of the combined ribs and the WVGs shows the significant increase in heat transfer rate and friction loss over the smooth channel. The Nusselt number and friction factor values obtained from combined the ribs and the WVGs are found to be much higher than those from the ribs/WVGs alone. In conjunction with the WVGs, the in-line wedge pointing downstream provides the highest increase in both the heat transfer rate and the friction factor while the staggered wedge pointing upstream yields the best thermal performance. © 2009 Elsevier Ltd. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Augmented thermal effectiveness in solar air receiver with flapped curved winglets: Experimental and numerical analysis(2025-12-01) ;Sripattanapipat, Somchai; ; ;Promthaisong, PitakNakhchi, Mahdi ErfanianThermal effectiveness was examined on a solar air receiver equipped with a new lengthwise vortex generator, namely a flapped curved winglet (FCW) mounted on the absorber, utilizing experimental and numerical approaches. Two arrays were employed to assemble two FCWs on the absorber at an angle of attack (α = 59.5°). The FCWs' V-tips were orientated upstream (VU-FCW) and downstream (VD-FCW). Air served as the working fluid, entering a constantly heat-fluxed channel at Reynolds numbers (Re) varying from 5280 to 22,510. Three relative winglet pitches (P<inf>R</inf> = P/H = 1.0–2.0), five winglet-mounted flap angles (β = 0° - 90°), and one winglet blockage ratio (b/H=B<inf>R</inf> = 0.6) were among the major factors. According to the findings, lowering P<inf>R</inf> and β greatly enhances the f (friction factor) and Nu (Nusselt number) of the two FCW arrays. The FCW with P<inf>R</inf> = 1.0 and β = 0° has the largest Nu and f values, approximately 8.3 and 77.39 times bigger than the smooth flat channel, as per the test data. The maximal thermal effectiveness factors (TEF) of the VD-FCW and VU-FCW were approximately 2.83 and 2.61, respectively, at comparable β = 45° and P<inf>R</inf> = 1.5. The f and Nu correlations in employing FCW were also provided. A 3D computational analysis employing the realizable k-ε turbulence model was conducted to examine heat transmission and flow patterns, with the corresponding measured data validating the expected results. The numerical and measured data sets yielded consistent results, and the FCW's heat transmission mechanism was also described. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Analysis of exergy and heat transfer in a tube fitted with flapped V-baffles(2024-07-01); ; ;Tongyote, Paritkavin ;Skullong, SompolNakhchi, Mahdi ErfanianVortex generator is a device that shows promise in generating streamwise vortices that can be utilized for boosting the rate of heat transmission inside a cooling/heating system with a relatively smaller penalty in terms of friction loss. The primary goal of the current research is to maximize the comparative Nusselt number ratio (Nu/Nu<inf>0</inf>) to be as large as possible to lower the size of the system while keeping thermal performance as high as feasible to save more energy. Thus, in the current study, the impacts of inserting the flapped V-baffle vortex generator (FBVG) on the thermal effectiveness improvement of a round tube were experimentally investigated. At a fixed attack angle (α = 60°) and baffle blockage ratio (B<inf>R</inf> = b/D = 0.3), the geometrical behaviors of FBVGs placed periodically along two edges of a straight tape were six different flap angles (θ = 0°, 25°, 35°, 45°, 65° and 90°) and three ratios of baffle pitches (P/D = P<inf>R</inf> = 2.0, 1.5, and 1.0). The current V-baffles, which were positioned on both tape edges, were designed to reduce friction loss caused by interrupting the central core flow when placed on both tape sides. The measurement results focused on the friction loss and thermal behaviors, including exergy and entropy analyses for Reynolds number from 4750 to 29,270. In the findings, the Nusselt number and friction factor of FBVG at θ = 0° and P<inf>R</inf> = 1 are, respectively, up to 5.6 and 35.24 times larger than those of the smooth tube. The entropy generation (S˙<inf>gen</inf><sup>′</sup>) seems to decline as θ and P<inf>R</inf> increase, with the smallest S˙<inf>gen</inf><sup>′</sup> found at θ = 0° and P<inf>R</inf> = 1 for lower Re. The FBVG has the greatest exergy efficiency (η<inf>Ex</inf>) at θ = 0° and P<inf>R</inf> = 1. To find the true benefits of FBVG, its thermal performance is estimated and seen to reach a maximum at about 2.44 with Nu<inf>R</inf> = 4.65 at θ = 45° and P<inf>R</inf> = 1. The optimal scenario at θ = 25° and P<inf>R</inf> = 1 was preferred, however, since it yielded the largest Nu<inf>R</inf> = 5.42 at TEF = 2.39. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Entropy generation and thermal performance of tubular heat exchanger fitted with louvered corner-curved V-baffles(2023-02-01); ; ; Skullong, SompolThe current article deals with an experimental study on entropy generation analysis and thermohydraulic performance of a uniform heat-flux tube equipped with louvered corner-curved baffle tape (LCBT). Air was drawn into the inserted tube for the Reynolds number (Re) between 4760 and 29,300. The V-shaped LCBT arranged by V-tip in downstream direction was introduced with three baffle pitch ratios (P<inf>R</inf> = 1–2) and six louver angles (θ = 0–90°) for a fixed attack angle (α) of 30° and baffle height ratio (B<inf>R</inf> = 0.25). The impacts of investigated parameters on the thermal enhancement factor (TEF), Nusselt number (Nu), friction factor (f), and total entropy generation (S˙<inf>gen</inf><sup>′</sup>) were examined. The measurements showed that the LCBT with the smallest values of P<inf>R</inf> = 1, θ = 0° give the largest Nu and f at about 4.4 and 19.2 times above the plain tube values, respectively. However, the greatest TEF around 2.23 was seen for employing the LCBT at P<inf>R</inf> = 1, θ = 45°. The entropy analysis also showed that the S˙<inf>gen</inf><sup>′</sup> is found to decline with the increment of P<inf>R</inf> and θ, whereas the minimal S˙<inf>gen</inf><sup>′</sup>is at P<inf>R</inf> = 1, θ = 0° for lower Re but at P<inf>R</inf> = 1, θ = 45° for higher Re. Furthermore, the Nu and f empirical correlations for employing LCBTs were also proposed. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal characterization in a circular tube fitted with inclined horseshoe baffles(2015-01-22); ;Tamna, Sombat; In the present study, the influence of inclined horseshoes baffles placed repeatedly in a tubular heat exchanger on heat transfer rate, friction factor and thermal enhancement factor are experimentally determined. The horseshoe baffle elements with an inclination angle of 20° were inserted periodically into the test tube at three different baffle-pitch ratios (P<inf>R</inf> = 0.5, 1.0 and 2) and -width or blockage ratios (B<inf>R</inf> = 0.1, 0.15 and 0.2). The experiment was conducted in the test tube having a uniform heat-fluxed wall by varying turbulent airflow to obtain Reynolds number in a range of 5300-24,000. The experimental results revealed that the tube fitted with inclined horseshoes baffles provides considerable improvement of the heat transfer rate over the plain tube around 92-208% while the friction factor is increased at about 1.76-6.37 times. To access the real benefits for the inclined horseshoes baffles inserted in plain tube, thermal performance factor is examined and found to be in the range of 1.34-1.92 at which the maximum obtained at P<inf>R</inf> = 0.5 and B<inf>R</inf> = 0.1 is considerably higher than that for published inserted devices. Correlations for Nusselt number and friction factor for the oblique horseshoe-baffled tube are also proposed. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal performance of heat exchanger tube inserted with curved-winglet tapes(2018-01-25) ;Skullong, Sompol; ; ; The paper deals with the effect of curved-winglet (CW) inserts on thermal and flow behaviors in a constant heat-fluxed tube. A straight tape is used to support the 45° CWs mounted repeatedly on both tape sides to generate two pairs of longitudinal counter-rotating vortices along the test tube in order to assist the chaotic flow mixing and to disrupt the boundary layer leading to faster rate of heat transfer. The airflow and heat transfer behaviors in the tube are examined for Reynolds number (Re) in the range of 4150–25,400. The curved-winglet tape (CWT) parameters involved are the winglet attack angle of 45° three relative winglet heights (b/D = B<inf>R</inf> = 0.1, 0.2 and 0.3) and winglet pitches, (P/D = P<inf>R</inf> = 0.5, 1.0 and 2.0). The investigation reveals that the maximum thermal enhancement factor (TEF) of the CWT is about 1.62 at B<inf>R</inf> = 0.1 and P<inf>R</inf> = 1.0. For further improvement, the CWT at B<inf>R</inf> = 0.1 and P<inf>R</inf> = 1.0 is modified by punching the CW to be the perforated-curved-winglet tape (P-CWT) to reduce the pressure loss. The P-CWT characteristics include five different punched hole diameters (d = 1.0, 1.5, 2.0, 2.5 and 3.0 mm). The experimental results show that TEF of all the P-CWTs is higher than that of the CWT and the maximum TEF of 1.76 higher than the CWT around 9% is found for d = 1.5 mm. To understand the flow pattern and heat transfer mechanism, a three-dimensional CFD investigation is also performed and for validation, the good agreement between numerical and experimental results is found. For experimental data, empirical correlations for Nu, f and TEF for the CWT and P-CWT inserts are also determined. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermohydraulic performance and entropy generation in heat exchanger tube with louvered winglet tapes(2022-11-01); Skullong, SompolThe present article concerns with thermohydraulic performance, flow friction and entropy generation analysis in a heated tube contained with louvered winglet tape (LWT). The experiment was conducted in a uniform heat-fluxed test tube for turbulent fluid flow, Reynolds number (Re) ranging from 4760 to 29,260. The purpose of the LWT insert is to produce streamwise vortices assisting to induce impinging-jets onto the tube wall and to decline the pressure loss through the louver mounted on the winglet aside from providing rapid mixing of fluid flow. In the present experiment, the louvered winglets were mounted periodically on a double-sided straight tape with six different louver angles (θ = 0 ˗ 90°) and three winglet pitch ratios (P<inf>R</inf> = 1 ˗ 2) at a single relative winglet height (B<inf>R</inf> = 0.25) and a fixed attack angle (α) of 30°. There were two-types of LWT arrangements: inline and staggered louvered-winglet tapes (I-LWT and S-LWT). To examine the optimum thermohydraulic performance, an influence of θ at each P<inf>R</inf> on the rate of heat transfer and friction loss inside the tube was explored. The measured results disclosed that the Nusselt number (Nu) and friction factor (f) from using both types of LWTs rise considerably with the reduction of P<inf>R</inf> and θ. The entropy generation (S˙<inf>gen</inf><sup>'</sup>) was declined with the decrease in Re, P<inf>R</inf> and θ where the minimum S˙<inf>gen</inf><sup>'</sup> was obtained for the I-LWT tube at P<inf>R</inf> = 1, θ = 0° and lowest Re. The peak thermal enhancement factors (TEF) of the S-LWT and the I-LWT were, respectively, around 2.22 and 2.18 at similar P<inf>R</inf> = 1, θ = 45°. The Nu, f and TEF correlations for using LWT insert were also reported. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Enhanced thermal effectiveness of square duct with V-type double-baffles: Numerical study(2024-09-01); ;Sripattanapipat, Somchai; ;Skullong, SompolPromthaisong, PitakThe article puts forward three-dimensional computational research on heat transmission augmentation within a square channel containing 45<sup>o</sup> V-type double-baffles positioned on the lower and top parts at regular intervals in the turbulence zone for Reynolds numbers (Re) that vary from 3000 to 20,000. The primary goal of this research is to increase the thermal effectiveness and relative Nusselt number (Nu/Nu<inf>0</inf>), in order to conserve energy and reduce the size of the heating or cooling system. The simulations utilize a finite volume approach in common with the SIMPLE algorithm, whereas the turbulent model used is the realizable k–ε. The baffles are designed to be separated vertically for reducing pressure loss. Both single V-baffles and double V-baffles have four relative pitches (PR = 0.4, 0.5, 0.6, and 1.0) and height/blockage ratios (BR = 0.05, 0.1, 0.15, and 0.2), with a fixed attack angle (α) of 45<sup>o</sup>. The computational findings show that both V-baffles are capable of producing the primary vortices, but only the double V-baffles have the ability to provide the impinging streams onto the wall, cooling the region behind the baffles. This suggests that the double V-baffles not only boost heat transmission but also reduce frictional loss. When compared to a single V-baffle, the double ones enhance heat transfer by an average of 1.04–9.94% while decreasing frictional loss by an average of 9.88–31.73%. The thermal effectiveness factor (TEF) of the double V-baffles ranges from 1.03 to 3.21, and its peak value of around 3.21 is for PR = 0.4, BR = 0.05, at lower Re. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermal characteristics in solar air duct with V-shaped flapped-baffles and chamfered-grooves(2021-06-01); Skullong, SompolThe article deals with augmenting the thermohydraulic performance of a solar heat exchanger duct with combined V-shaped baffle-and-groove vortex generators (VGs). Heat transfer behaviors from the combined VGs mounted in the duct absorber were investigated experimentally. Two VGs mounted on the absorber plate, the V-shaped flapped-baffle and chamfered-groove with a similar attack angle, α = 45°, were arranged by two arrays: V-apex pointing upstream (VU) and pointing downstream (VD). The vital purpose of using the flapped-wing mounted on the baffle (called “flapped baffle”) is to decline the pressure loss from the baffle without deterioration of the main vortices behind. The present experiment was carried out to encompass Reynolds number (Re) in a range of 5290 to 22,600, using air as a working fluid. The pertinent parameters of grooves were three groove pitch ratios (P<inf>R</inf> = 1.0, 1.5 and 2.0) while the baffle characteristics included four flap angles of the flap mounted on the baffle central area (β = 30°, 45°, 60° and 90°), three relative baffle pitches (P<inf>R</inf> = 1.0, 1.5 and 2.0) at one baffle height. Effects of the baffle and groove parameters as stated above on Nusselt number (Nu), friction factor (f) and thermal enhancement factor (TEF) were examined. The experimental results have revealed that the use of flapped-baffle and groove VG devices at P<inf>R</inf> =1.0 and β = 30° gives the largest f and Nu, especially for the VU case owing to strongly impinging jets issuing from the flap opening on the absorber surface area behind the baffle. Specifically, the maximum TEF is found to be 2.68 for the combined VU devices with P<inf>R</inf>=1.5, β = 45° and Re=5290. With these measured data, the Nu and f correlations are also determined. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Enhanced thermal performance in tubular heat exchanger contained with V-shaped baffles(2021-02-25); Skullong, SompolThe vortex-flow device is a promising streamwise vortex generator employed to produce the counter-rotating vortices along a heated tube to augment the heat transfer rate with comparatively smaller friction loss penalty. Thus, the influences of V-shaped baffle vortex generator (hereafter called “V-baffle”) insert in a heated tube on thermal-performance enhancement were experimentally examined in the current work. The geometric characteristics of the V-baffles mounted repeatedly on the edges of a flat plate/tape were three ratios of relative baffle blockages, (b/D = B<inf>R</inf> = 0.1, 0.15 and 0.2), and four ratios of baffle pitches, (P/D = P<inf>R</inf> = 0.5, 1.0, 1.5 and 2.0) at a fixed angle of attack (α = 30°). The present V-baffle placed on the tape edge was aimed to lessen the pressure loss from disturbing the central core flow for the case of placing it on the double sides of a tape as found in the literature. The experiment was conducted by letting air flow through the test tube with Reynolds number (Re) in the range of 4192 to 25,750. The current study indicated that the friction factor and heat transfer using the V-baffle inserts increase considerably with rising B<inf>R</inf> but reducing P<inf>R</inf>. The V-baffle with B<inf>R</inf> = 0.2, P<inf>R</inf> = 0.5 provides the highest friction factor and rate of heat transfer at about 18.25 and 4.46 times above the plain tube, respectively. A new modified thermal enhancement factor (TEF) is offered and found that its peak for each case appearing at the lowest Re, is in a range of 2.14–2.34 where the optimum TEF of 2.34 is visible at P<inf>R</inf> = 1.0, B<inf>R</inf> = 0.15. Furthermore, correlations of Nusselt number and friction factor for the present V-baffles are determined. TEF of the current device is found to be superior to that of other enhanced devices in comparison.
