Promvonge, Pongjet
Loading...
Preferred name
Promvonge, Pongjet
Alternative Name
Promvonge, P.
Main Affiliation
Email
pongjet.pr@kmitl.ac.th
139 results
Now showing 1 - 10 of 139
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Rice husk combustion characteristics in a rectangular fluidized-bed combustor with triple pairs of chevron-shaped discrete ribbed walls(2019-09-01) ;Chokphoemphun, Suriya ;Eiamsa-Ard, Smith; An experimental combustion work using the rice husk as a fuel was performed in a rectangular fluidized bed combustor with triple pairs of chevron-shaped discrete ribbed walls. The effect of percent excess air (EA = 40%-70%) on temperature distribution and gas emissions in a rectangular fluidized-bed combustor on combustion behaviors (temperature distributions inside the bed, exhaust gas emissions and combustion efficiency) is reported. The free-board had a rectangular shape which modified by increasing the chamber size from 300 × 100 mm<sup>2</sup> to 600 × 200 mm<sup>2</sup> or two times of the bottom chamber and 2400 mm in height. Triple pairs of rib configurations, namely, 30° chevron-shaped discrete ribbed walls were introduced and placed in the bottom part of the combustion chamber to generate counter-rotating vortices in the chamber. The results show that the fluidized bed combustor with 30° chevron-shaped discrete ribbed walls at 40% percent excess air provides the higher temperature than other of 861 °C. Among the studied excess air percentages, the highest combustion efficiency of 99.2% is obtained at EA = 60%. In addition, combustion at EA = 60% shows the lowest emissions CO, CO<inf>2</inf>, O<inf>2</inf> and NO<inf>x</inf> of 236.8%Vol, 2.55 ppm, 13.53 %Vol, 110.2 ppm, respectively. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Heat transfer augmentation in a wedge-ribbed channel using winglet vortex generators(2010-02-01) ;Chompookham, Teerapat; ; Experimental investigations have been carried out to study the effect of combined wedge ribs and winglet type vortex generators (WVGs) on heat transfer and friction loss behaviors for turbulent airflow through a constant heat flux channel. To create a reverse flow in the channel, two types of wedge (right-triangle) ribs are introduced: wedge ribs pointing downstream and pointing upstream. The arrangements of both rib types placed inside the opposite channel walls are in-line and staggered arrays. To generate longitudinal vortex flows through the tested section, two pairs of the WVGs with the attack angle of 60° are mounted on the test channel entrance. The test channel has an aspect ratio, AR = 10 and height, H = 30 mm with a rib height, e/H = 0.2 and rib pitch, P/H = 1.33. The flow rate in terms of Reynolds numbers is based on the inlet hydraulic diameter of the channel ranging from 5000 to 22,000. The presence of the combined ribs and the WVGs shows the significant increase in heat transfer rate and friction loss over the smooth channel. The Nusselt number and friction factor values obtained from combined the ribs and the WVGs are found to be much higher than those from the ribs/WVGs alone. In conjunction with the WVGs, the in-line wedge pointing downstream provides the highest increase in both the heat transfer rate and the friction factor while the staggered wedge pointing upstream yields the best thermal performance. © 2009 Elsevier Ltd. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Numerical investigation of laminar heat transfer in a square channel with 45° inclined baffles(2010-02-01); ;Sripattanapipat, S. ;Tamna, S.; A numerical investigation of laminar periodic flow and heat transfer in a three-dimensional isothermal-wall square channel fitted with 45° inclined baffles on one channel wall is carried out in the present work. The finite volume method is introduced and the SIMPLE algorithm has been implemented for all computations. The fluid flow and heat transfer characteristics are presented for Reynolds numbers ranging from 100 to 1200. The 45° baffle mounted only on the lower channel wall has a height of b and an axial pitch length (L) equal to channel height (H). Effects of flow blockage ratios, BR = b/H = 0.1-0.5, on heat transfer and pressure loss in the square channel are examined and also compared with the typical case of the transverse baffle (or 90° baffle). It is found that apart from the rise of Reynolds number, the increase in the blockage ratio with the attack angle (α) of 45° results in considerable increases in the Nusselt number and friction factor values. The use of the 45° baffle can help to generate a streamwise main vortex flow throughout the channel leading to fast and chaotic mixing of flow between the core and the wall regions. In addition, the computational results reveal that the significant increase in heat transfer rate is due to impingement jets induced by a longitudinal vortex pair (P-vortex) of flow, appearing on the upper, lower and baffle trailing end side walls. The appearance of vortex-induced impingement flows created by the baffles leads to the maximum thermal enhancement factor of about 2.2 at BR = 0.4 and Re = 1200. The enhancement factor of the 45° baffle investigated is found to be higher than that of the 90° baffle for all Reynolds numbers and baffle heights. © 2009 Elsevier Ltd. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Numerical heat transfer study of square duct equipped with novel flapped V-baffles(2024-03-01); ; ;Skullong, Sompol ;Promthaisong, PitakNakhchi, Mahdi ErfanianThe paper describes a computational study of heat transfer enhancement inside a square duct with V-shaped flapped baffles located repeatedly on the bottom and top walls for fluid flowing with Reynolds numbers (Re) from 3000 to 21,000. The basic goal of this work is to attain the largest relative Nusselt number (Nu/Nu<inf>0</inf>) whilst maintaining the highest thermal performance to improve energy savings. A finite volume method was used in the computations, along with the Realizable k‒ε turbulent model. The variable baffle parameters considered first in the current simulation were the relative height/blockade ratio (B<inf>R</inf> = 0.05−0.2) and the flap angle of the baffle hole (β = 0° − 90°), while the fixed parameters included the attack angle (α = 60°), hole diameter ratio (d<inf>R</inf> = 0.5), and pitch ratio (P<inf>R</inf> = 0.5). To accomplish this goal, the previously mentioned parameters providing the best thermal performance were investigated further by extending the values of B<inf>R</inf> to 0.25−0.3, d<inf>R</inf> to 0.8 and α to 45°−30°. The simulation results indicate that the jet flowing from the flapped hole, as well as the vortices created by the baffle, can boost heat transfer and friction loss in comparison to the plain duct. In comparison, using a flapped baffle with β > 0° results in less friction loss, a greater thermal enhancement factor (TEF), and a higher Nusselt number than using a baffle with no flap. The first investigation disclosed that for B<inf>R</inf> = 0.2 and β = 20°, the greatest TEF of 2.19 with Nu/Nu<inf>0</inf> of 7.9 times are obtained. The extended study, on the other hand, showed that the highest TEF of roughly 2.49 with Nu/Nu<inf>0</inf> of 8.4 times are seen for α = 45°, d<inf>R</inf> = 0.8, B<inf>R</inf> = 0.25 and β = 20° at lowest Re. Thus, the flapped baffle provides a significant increase in Nu/Nu<inf>0</inf> and TEF over the baffle alone. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Heat transfer behavior in a square duct with tandem wire coil element insert(2012-01-01) ;Eiamsa-Ard, Smith ;Koolnapadol, NarinEffects of insertion of tandem wire coil elements used as turbulator on heat transfer and turbulent flow friction characteristics in a uniform heat-flux square duct are experimentally investigated in this work. The experiment is conducted for turbulent flow with the Reynolds number from 4000 to 25000. The wire coil element is inserted into the duct with a view to generating a swirl flow that assists to wash up the flow trapped in the duct corners and then increase the heat transfer rate of the test duct. Apart from the full-length coil, 1D and 2D length coil elements placed in tandem inside the duct with various free-space lengths are introduced to reduce the friction loss. The results obtained from these wire coil element inserts are also compared with those from the smooth duct. The experimental results reveal that the use of wire coil inserts for the full-length coil, 1D and 2D coil elements with a short free-space length leads to a considerable increase in heat transfer and friction loss over the smooth duct with no insert. The full-length wire coil provides higher heat transfer and friction factor than the tandem wire coil elements under the same operating conditions. Also, performance evaluation criteria to assess the real benefits in using the wire coil insert into the square duct are determined. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Thermo-hydraulic performance in heat exchanger tube with V-shaped winglet vortex generator(2020-01-05); Skullong, SompolThis article presents the influence of V-shaped winglet vortex generators (V-WVGs) inserted into a constant heat-fluxed tube on thermal characteristics. In the present experiment, two V-WVG types: V-shaped rectangular- and delta-winglets (V-RW and V-DW) were mounted periodically on both sides of a straight tape before insertion into the tube with four relative winglet pitches (P<inf>R</inf> = P/D = 0.5, 1.0, 1.5 and 2.0) and three winglet blockage ratios (B<inf>R</inf> = b/D = 0.1, 0.15 and 0.2) at a fixed attack angle (α = 45°). Effects of geometric parameters of both V-WVGs on thermal performance enhancement were studied using air as tested fluid in a turbulence condition, Reynolds number (Re) ranging between 4130 and 25,900. The measured result has been shown that the V-RW performs higher rate of heat transfer as well as friction loss than the V-DW and the rise in B<inf>R</inf> results in higher increase of the heat transfer rate and friction loss while the increment in P<inf>R</inf> yields the reversing tendency for both V-WVG types. A new thermal-performance enhancement factor (TEF) has been introduced and it reveals that the V-DW has TEF in a range of 1.82–2.0 or around 3% above the V-RW where its peak regarded as the optimal point is at B<inf>R</inf> = 0.15 and P<inf>R</inf> = 1.0. Empirical correlations for the Nusselt number and friction factor to assess the real merits of a heat exchanger tube with V-WVGs are determined. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Numerical study on heat transfer of turbulent channel flow over periodic grooves(2008-08-01) ;Eiamsa-ard, SmithA numerical investigation of turbulent forced convection in a two-dimensional channel with periodic transverse grooves on the lower channel wall is conducted. The lower wall is subjected to a uniform heat flux condition while the upper wall is insulated. To investigate turbulence model effects, computations based on a finite volume method, are carried out by utilizing four turbulence models: the standard k - ε, the Renormalized Group (RNG) k - ε, the standard k - ω, and the shear stress transport (SST) k - ω turbulence models. Parametric runs are made for Reynolds numbers ranging from 6000 to 18,000 with the groove-width to channel-height ratio (B/H) of 0.5 to 1.75 while the groove pitch ratio of 2 and the depth ratio of 0.5 are fixed throughout. The predicted results from using several turbulence models reveal that the RNG and the k - ε turbulence models generally provide better agreement with available measurements than others. Therefore, the k - ε model is selected to use in prediction of this complex flow. In addition, the results of the heat transfer coefficient, friction factor, skin friction coefficient and thermal enhancement factor are also examined. It is found that the grooved channel provides a considerable increase in heat transfer at about 158% over the smooth channel and a maximum gain of 1.33 on thermal performance factor is obtained for the case of B/H = 0.75. This indicates that the reverse/re-circulation flow in a channel with transverse grooves can improve the heat transfer rate. © 2008 Elsevier Ltd. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Augmented thermal effectiveness in solar air receiver with flapped curved winglets: Experimental and numerical analysis(2025-12-01) ;Sripattanapipat, Somchai; ; ;Promthaisong, PitakNakhchi, Mahdi ErfanianThermal effectiveness was examined on a solar air receiver equipped with a new lengthwise vortex generator, namely a flapped curved winglet (FCW) mounted on the absorber, utilizing experimental and numerical approaches. Two arrays were employed to assemble two FCWs on the absorber at an angle of attack (α = 59.5°). The FCWs' V-tips were orientated upstream (VU-FCW) and downstream (VD-FCW). Air served as the working fluid, entering a constantly heat-fluxed channel at Reynolds numbers (Re) varying from 5280 to 22,510. Three relative winglet pitches (P<inf>R</inf> = P/H = 1.0–2.0), five winglet-mounted flap angles (β = 0° - 90°), and one winglet blockage ratio (b/H=B<inf>R</inf> = 0.6) were among the major factors. According to the findings, lowering P<inf>R</inf> and β greatly enhances the f (friction factor) and Nu (Nusselt number) of the two FCW arrays. The FCW with P<inf>R</inf> = 1.0 and β = 0° has the largest Nu and f values, approximately 8.3 and 77.39 times bigger than the smooth flat channel, as per the test data. The maximal thermal effectiveness factors (TEF) of the VD-FCW and VU-FCW were approximately 2.83 and 2.61, respectively, at comparable β = 45° and P<inf>R</inf> = 1.5. The f and Nu correlations in employing FCW were also provided. A 3D computational analysis employing the realizable k-ε turbulence model was conducted to examine heat transmission and flow patterns, with the corresponding measured data validating the expected results. The numerical and measured data sets yielded consistent results, and the FCW's heat transmission mechanism was also described. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Analysis of exergy and heat transfer in a tube fitted with flapped V-baffles(2024-07-01); ; ;Tongyote, Paritkavin ;Skullong, SompolNakhchi, Mahdi ErfanianVortex generator is a device that shows promise in generating streamwise vortices that can be utilized for boosting the rate of heat transmission inside a cooling/heating system with a relatively smaller penalty in terms of friction loss. The primary goal of the current research is to maximize the comparative Nusselt number ratio (Nu/Nu<inf>0</inf>) to be as large as possible to lower the size of the system while keeping thermal performance as high as feasible to save more energy. Thus, in the current study, the impacts of inserting the flapped V-baffle vortex generator (FBVG) on the thermal effectiveness improvement of a round tube were experimentally investigated. At a fixed attack angle (α = 60°) and baffle blockage ratio (B<inf>R</inf> = b/D = 0.3), the geometrical behaviors of FBVGs placed periodically along two edges of a straight tape were six different flap angles (θ = 0°, 25°, 35°, 45°, 65° and 90°) and three ratios of baffle pitches (P/D = P<inf>R</inf> = 2.0, 1.5, and 1.0). The current V-baffles, which were positioned on both tape edges, were designed to reduce friction loss caused by interrupting the central core flow when placed on both tape sides. The measurement results focused on the friction loss and thermal behaviors, including exergy and entropy analyses for Reynolds number from 4750 to 29,270. In the findings, the Nusselt number and friction factor of FBVG at θ = 0° and P<inf>R</inf> = 1 are, respectively, up to 5.6 and 35.24 times larger than those of the smooth tube. The entropy generation (S˙<inf>gen</inf><sup>′</sup>) seems to decline as θ and P<inf>R</inf> increase, with the smallest S˙<inf>gen</inf><sup>′</sup> found at θ = 0° and P<inf>R</inf> = 1 for lower Re. The FBVG has the greatest exergy efficiency (η<inf>Ex</inf>) at θ = 0° and P<inf>R</inf> = 1. To find the true benefits of FBVG, its thermal performance is estimated and seen to reach a maximum at about 2.44 with Nu<inf>R</inf> = 4.65 at θ = 45° and P<inf>R</inf> = 1. The optimal scenario at θ = 25° and P<inf>R</inf> = 1 was preferred, however, since it yielded the largest Nu<inf>R</inf> = 5.42 at TEF = 2.39. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Entropy generation and thermal performance of tubular heat exchanger fitted with louvered corner-curved V-baffles(2023-02-01); ; ; Skullong, SompolThe current article deals with an experimental study on entropy generation analysis and thermohydraulic performance of a uniform heat-flux tube equipped with louvered corner-curved baffle tape (LCBT). Air was drawn into the inserted tube for the Reynolds number (Re) between 4760 and 29,300. The V-shaped LCBT arranged by V-tip in downstream direction was introduced with three baffle pitch ratios (P<inf>R</inf> = 1–2) and six louver angles (θ = 0–90°) for a fixed attack angle (α) of 30° and baffle height ratio (B<inf>R</inf> = 0.25). The impacts of investigated parameters on the thermal enhancement factor (TEF), Nusselt number (Nu), friction factor (f), and total entropy generation (S˙<inf>gen</inf><sup>′</sup>) were examined. The measurements showed that the LCBT with the smallest values of P<inf>R</inf> = 1, θ = 0° give the largest Nu and f at about 4.4 and 19.2 times above the plain tube values, respectively. However, the greatest TEF around 2.23 was seen for employing the LCBT at P<inf>R</inf> = 1, θ = 45°. The entropy analysis also showed that the S˙<inf>gen</inf><sup>′</sup> is found to decline with the increment of P<inf>R</inf> and θ, whereas the minimal S˙<inf>gen</inf><sup>′</sup>is at P<inf>R</inf> = 1, θ = 0° for lower Re but at P<inf>R</inf> = 1, θ = 45° for higher Re. Furthermore, the Nu and f empirical correlations for employing LCBTs were also proposed.