Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. An investigation of oil residue on surface by infrared thermography
Loading...
Thumbnail Image

An investigation of oil residue on surface by infrared thermography

Author(s)
Chaishome, Jedsada
Nunak, Teerawat
Tuppadung, Yutthapong
Suesut, Taweepol
Nunak, Navaphattra
Date Issued
January 1, 2020
Type
Article
Abstract
This work aims to propose a visual inspection, infrared thermography technique, of oil residual mass on stainless steel surface (SS) (hydrophilic surface representative) and polytetrafluoroethylene (PTFE) surface (hydrophobic surface representative). An improved understanding of the oil fouling characteristic is a key point to develop this technique. The effect of surface roughness on the oil contact angle, oil residual mass, and the resulting average temperature of the residues on SS and PTFE surface was studied. For the infrared thermography technique, the mass of oil adhered to each interface using heating at a temperature of 800C for 10 minutes. SS AISI 304 plaques with the average surface roughness of 0.4, 0.8, and 3.2 µm and PTFE with that of 0.4 and 0.8 µm were examined. All samples were snapped top view using a thermal image camera. The average temperatures were obtained from the color spectrum of the thermal images. It could be summarized that the proposed measurement is possible to detect the accumulation of oil on the SS whereas it was not clearly different that on the PTFE surface. A greater oil residual mass on both hydrophilic and hydrophobic surfaces is a result of an increase in surface roughness and sequential wettability from the contact angle as expected. Moreover, each liquid-solid interfacial material has its specific surface characteristic. Finally, each liquid-solid interfacial material has its specific surface characteristic and the new and used oil-SS interface could be detected by infrared thermography technique.
Citation
Journal of Hygienic Engineering and Design, 32, 3-7, 2020
Subjects

Average roughness

Contact angle

Infrared thermography...

Residual mass

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback