    Mechanical compliance of the endocardium
    (2002-12-01)
    Bin Choy, Young
    ;
    Cao, Hong
    ;
    ;
    Tsai, Jang Zern
    ;
    Haemmerich, Dieter
    Radio-frequency (RF) ablation is an accepted treatment for cardiac arrhythmias related to abnormal focal cardiac substrate. The penetration depth of the electrode into the endocardium affects lesion size, a critical determinant of success of RF ablation. We measured the relation between the mechanical compliance and the penetration depth of RF ablation catheter electrode at frequently ablated areas of the endocardium and examined the influence of time after death on mechanical properties of the tissue. We measured force versus time for eight insertion depths of the catheter electrode into full-thickness endocardial samples derived from the mitral valve annulus, the left ventricular free wall and the tricuspid valve annulus. We varied the time after death at 15, 40min, 3, 8, and 18h and repeated our measurements. At 15min after death, the first 0.5mm penetration depth caused the fastest relaxation at 55s. Force decay decreased dramatically at 15min after death as the penetration depth increased from 0.5 to 4mm. We used the force data sampled at 60s after insertion to approximate the elasticity. We observed the relations between the force versus the insertion depth. The force increased by a factor of 5 for the mitral valve annulus and 8 for the left free wall from 15min to 18h. We derived coefficients of a second-order polynomial equation relating the force data to insertion depth with R<sup>2</sup>>0.99. © 2002 Elsevier Science Ltd. All rights reserved.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Cross-Sensor and Cross-Population Generalization of Deep Learning Models for Digital Mammography: A Controlled Four-Country Benchmark of Five Backbone Architectures with Statistical Significance Testing
    (2026-06-01)
    Gabbualoy, Somprasonk
    ;
    ;
    Background/Objectives: Deep learning models for digital mammography sensor data are increasingly deployed across hospitals using different X-ray detector technologies and patient populations. Whether models trained on one sensor platform and population maintain accuracy when transferred to another has not been tested for the latest generation of mammography-specific foundation models under one controlled protocol. Methods: We fine-tuned five backbone architectures (ResNet-50, DINOv2-B14, Rad-DINO, Mammo-CLIP B5, and Mammo-FM) on CBIS-DDSM (film-digitized, USA, n = 714 validation) with three seeds, ablated a density-aware focal loss across three auxiliary weights, and evaluated transfer to three external sensor cohorts: CMMD (full-field digital, China, n = 1032), DMID (mixed digital, India, n = 509), and MIAS (film-digitized, UK, n = 322). Significance used paired DeLong z-tests with Benjamini–Hochberg FDR correction; temperature scaling tested post hoc recalibration at all transfer targets. Results: Within this single-source three-seed evaluation, ResNet-50 outperformed all four foundation models on CBIS-DDSM (AUC 0.867 vs. 0.847, 0.846, 0.813, and 0.703; all gaps p_adj < 0.05). The density-aware focal loss degraded both AUC and calibration at every weight tested. At transfer, every model lost 0.165 to 0.320 AUC points relative to in-distribution performance, with sensitivity at 95% specificity collapsing from 0.31 to 0.47 in-distribution to 0.11 to 0.22 across the three external targets. A per-seed Stouffer meta-analysis confirms that Mammo-CLIP B5 and Mammo-FM significantly outperformed ResNet-50 on DMID and Mammo-CLIP on CMMD, after BH-FDR; MIAS comparisons remained directional only. In the extremely dense subgroup (BI-RADS D4), Mammo-FM reached AUC 0.870 versus ResNet-50 at 0.842, a directional observation whose 95% CIs overlap heavily at the n = 140 sample size and which we do not interpret as a statistically supported advantage. Conclusions: In this single training-source, three-seed protocol, mammography-specific pretraining did not deliver the in-distribution AUC premium reported in the originating papers, and no architecture reached a level at which transfer deployment without local validation would be defensible. We frame these as observations specific to the present protocol rather than as broader conclusions about foundation models for mammography classification. The findings argue for sensor-stratified and population-stratified external validation and for local recalibration as practical prerequisites before clinical use. Code and weights are released under MIT license.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Error analysis of tissue resistivity measurement
    (2002-04-30)
    Tsai, Jang Zern
    ;
    Will, James A.
    ;
    Stelle, Scott Hubbard Van
    ;
    Cao, Hong
    ;
    We identified the error sources in a system for measuring tissue resistivity at eight frequencies from 1 Hz to 1 MHz using the four-terminal method. We expressed the measured resistivity with an analytical formula containing all error terms. We conducted practical error measurements with in-vivo and bench-top experiments. We averaged errors at all frequencies for all measurements. The standard deviations of error of the quantization error of the 8-bit digital oscilloscope with voltage averaging, the nonideality of the circuit, the in-vivo motion artifact and electrical interference combined to yield an error of ±1.19%. The dimension error in measuring the syringe tube for measuring the reference saline resistivity added ±1.32% error. The estimation of the working probe constant by interpolating a set of probe constants measured in reference saline solutions added ±0.48% error. The difference in the current magnitudes used during the probe calibration and that during the tissue resistivity measurement caused ±0.14% error. Variation of the electrode spacing, alignment, and electrode surface property due to the insertion of electrodes into the tissue caused ±0.61% error. We combined the above errors to yield an overall standard deviation error of the measured tissue resistivity of ±1.96%.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Automated Crack Detection in Monolithic Zirconia Crowns Using Acoustic Emission and Deep Learning Techniques
    Monolithic zirconia (MZ) crowns are widely utilized in dental restorations, particularly for substantial tooth structure loss. Inspection, tactile, and radiographic examinations can be time-consuming and error-prone, which may delay diagnosis. Consequently, an objective, automatic, and reliable process is required for identifying dental crown defects. This study aimed to explore the potential of transforming acoustic emission (AE) signals to continuous wavelet transform (CWT), combined with Conventional Neural Network (CNN) to assist in crack detection. A new CNN image segmentation model, based on multi-class semantic segmentation using Inception-ResNet-v2, was developed. Real-time detection of AE signals under loads, which induce cracking, provided significant insights into crack formation in MZ crowns. Pencil lead breaking (PLB) was used to simulate crack propagation. The CWT and CNN models were used to automate the crack classification process. The Inception-ResNet-v2 architecture with transfer learning categorized the cracks in MZ crowns into five groups: labial, palatal, incisal, left, and right. After 2000 epochs, with a learning rate of 0.0001, the model achieved an accuracy of 99.4667%, demonstrating that deep learning significantly improved the localization of cracks in MZ crowns. This development can potentially aid dentists in clinical decision-making by facilitating the early detection and prevention of crack failures.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Patient-specific aided surgery approach of deviated nasal septum using computational fluid dynamics
    (2015-05-01)
    Hemtiwakorn, Khaisang
    ;
    Mahasitthiwat, Visan
    ;
    ;
    Hamamoto, Kazuhiko
    ;
    In treating a patient with deviated nasal septum (DNS), a surgeon draws up a surgical plan based on the patient's rhinomanometry outcomes and self-assessment of nose conditions, e.g. the nasal obstruction septoplasty effectiveness (NOSE) score. However, the procedure fails to localize the DNS and determine the nose's aerodynamic effects. This paper proposes a DNS-aided surgery approach using computational fluid dynamics (CFD) and computed tomography (CT) techniques consisting of three main processes: preoperative, presurgical planning, and postoperative processes. The healthy baseline refers to a benchmark consisting of five subjects without DNS and nasal airway obstructions. To assess the possibility of using the CFD-CT-aided surgery approach as a presurgical planning tool in the DNS operation, comparative tests were carried out with DNS patient #1, who received a conventional nasal surgery without the proposed presurgical planning. Although DNS patient #1's surgical outcome was relatively satisfying to the patient, evaluating from the reduction of the NOSE score the conventional surgical method could induce an excessive excision of nasal airway, resulting in water loss in the nasal mucosa and a large reduction in airflow velocity. In addition, the postoperative nasal resistance measured by a rhinomanometer was not acceptable to the surgeon. Virtual surgery using the CFD-CT approach performed after surgery could suggest suitable patient-specific components of nasal operation with predictable results. Subsequently, implementation of the proposed CFD-CT approach in aid of DNS surgery was performed in DNS patient #2. The benefits of the CFD-CT-aided surgery approach were determined based on the pre- and postoperative outcomes (i.e. nasal geometric data and nasal airflow patterns), NOSE scores, and rhinomanometric data of DNS patient #2, which were compared against those of the healthy baseline benchmark. The CFD-CT approach could assist the surgeon to localize the DNS and determine the defective nasal tissues to be removed. The actual postoperative outcomes were clinically acceptable to the surgeon and DNS patient #2. It is evident that the CFD-CT-aided surgery approach is suitable for and applicable to surgery of DNS patients with small variability from the presurgical planning stage.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Three-dimensional finite-element analyses for radio-frequency hepatic tumor ablation
    (2002-01-05) ;
    Staelin, S. Tyler
    ;
    Haemmerich, Dieter
    ;
    Tsai, Jang Zern
    ;
    Cao, Hong
    Radio-frequency (RF) hepatic ablation, offers an alternative method for the treatment of hepatic malignancies. We employed finite-element method (FEM) analysis to determine tissue temperature distribution during RF hepatic ablation. We constructed three-dimensional (3-D) thermal-electrical FEM models consisting of a four-tine RF probe, hepatic tissue, and a large blood vessel (10-mm diameter) located at different locations. We simulated our FEM analyses under temperature-controlled (90 °C) 8-min ablation. We also present a preliminary result from a simplified two-dimensional (2-D) FEM model that includes a bifurcated blood vessel. Lesion shapes created by the four-tine RF probe were mushroom-like, and were limited by the blood vessel. When the distance of the blood vessel was 5 mm from the nearest distal electrode 1) in the 3-D model, the maximum tissue temperature (hot spot) appeared next to electrods A. The location of the hot spot was adjacent to another electrode 2) on the opposite side when the blood vessel was 1 mm from electrode A. The temperature distribution in the 2-D model was highly nonuniform due to the presence of the bifurcated blood vessel. Underdosed areas might be present next to the blood vessel from which the tumor can regenerate.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Automated segmentation of infarct lesions in t1‐weighted mri scans using variational mode decomposition and deep learning
    Automated segmentation methods are critical for early detection, prompt actions, and immediate treatments in reducing disability and death risks of brain infarction. This paper aims to develop a fully automated method to segment the infarct lesions from T1‐weighted brain scans. As a key novelty, the proposed method combines variational mode decomposition and deep learning-based segmentation to take advantages of both methods and provide better results. There are three main technical contributions in this paper. First, variational mode decomposition is applied as a pre-processing to discriminate the infarct lesions from unwanted non‐infarct tissues. Second, overlapped patches strategy is proposed to reduce the workload of the deep‐learning‐based segmentation task. Finally, a three‐dimensional U‐Net model is developed to perform patch‐wise segmentation of infarct lesions. A total of 239 brain scans from a public dataset are utilized to develop and evaluate the proposed method. Empirical results reveal that the proposed automated segmentation can provide promising performances with an average dice similarity coefficient (DSC) of 0.6684, intersection over union (IoU) of 0.5022, and average symmetric surface distance (ASSD) of 0.3932, respectively.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Automatic detection of pulmonary nodules using three-dimensional chain coding and optimized random forest
    The detection of pulmonary nodules on computed tomography scans provides a clue for the early diagnosis of lung cancer. Manual detection mandates a heavy radiological workload as it identifies nodules slice-by-slice. This paper presents a fully automated nodule detection with three significant contributions. First, an automated seeded region growing is designed to segment the lung regions from the tomography scans. Second, a three-dimensional chain code algorithm is implemented to refine the border of the segmented lungs. Lastly, nodules inside the lungs are detected using an optimized random forest classifier. The experiments for our proposed detection are conducted using 888 scans from a public dataset, and achieves a favorable result of 93.11% accuracy, 94.86% sensitivity, and 91.37% specificity, with only 0.0863 false positives per exam.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    ECCCII-based current-mode universal filter with orthogonal control of ωo and Q
    (2014-01-01) ;
    Khateb, Fabian
    ;
    ; ;
    Junnapiya, Somyot
    This paper presents a new current-mode current- controlled four-input five-output universal filter employing one current-controlled current conveyor (CCCII), one electronically tunable CCCII and two grounded capacitors. The proposed configuration provides lowpass, bandpass, highpass, bandstop and allpass current responses that taken from the high-output impedance terminals, which enable easy cascadability of the current-mode operation. The filter also offers both orthogonal and electronic controls of the natural frequency and the quality factor through adjusting the bias current of the CCCIIs. For realizing all the filter responses, the proposed filter does not require passive component-matching condition and both active and passive sensitivities are low. In addition, a new current-mode current-controlled single-input five-output universal filter can be achieved by using an additional multiple-output minus-type CCCII. The proposed filter is simulated using PSPICE simulations to confirm the theoretical analysis.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Modeling bipolar phase-shifted multielectrode catheter ablation
    (2002-01-05) ;
    Haemmerich, Dieter
    ;
    Cao, Hong
    ;
    Tsai, Jang Zern
    ;
    Choy, Young Bin
    Atrial fibrillation (AFIB) is a common clinical problem affecting approximately 0.5-1% of the United States population. Radio-frequency (RF) multielectrode catheter (MEC) ablation has successes in curing AFIB. We utilized finite-element method analysis to determine the myocardial temperature distribution after 30 s, 80 °C temperature-controlled unipolar ablation using three 7F 12.5-mm electrodes with 2-mm interelectrode spacing MEC. Numerical results demonstrated that cold spots occurred at the edges of the middle electrode and hot spots at the side electrodes. We introduced the bipolar phase-shifted technique for RF energy delivery of MEC ablation. We determined the optimal phase-shift (φ) between the two sinusoidal voltage sources of a simplified two-dimensional finite-element model. At the optimal φ, we can achieve a temperature distribution that minimizes the difference between temperatures at electrode edges. We also studied the effects of myocardial electric conductivity (σ), thermal conductivity (κ), and the electrode spacing on the optimal φ. When we varied σ and κ from 50% to 150%, optimal φ ranged from 29.5° to 23.5°, and in the vicinity of 26.5°, respectively. The optimal φ for 3-mm spacing MEC was 30.5°. We show the design of a simplified bipolar phase-shifted MEC ablation system.